E-mail
wlj7783@163.com
- Phone
-
Address
Tengfei Road, Liushi Town, Yueqing City, Zhejiang Province
Zhejiang Mingchuan Electric Co., Ltd
wlj7783@163.com
Tengfei Road, Liushi Town, Yueqing City, Zhejiang Province
·Universal communication input range with small size, light weight, and high efficiency
·Protection: Over angle display/Over voltage/Over source degree
·Built in DC fan for forced air cooling
·Built in cooling fan switch control
·Built in active PFC function, PF>0.95
·Power indicator light
·100% full load aging test
·2-year warranty
|
model |
WB-500-12 | WB-500-15 | WB-500-24 | WB-500-27 | WB-500-36 | WB-500-48 | |
|
output |
DC voltage | 12V | 15V | 24V | 27V | 36V | 48V |
|
Voltage capacity |
±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
|
rated current |
40A | 32A | 20A | 18A | 13.5A | 10A | |
|
current range |
0-40A | 0-32A | 0-20A | 0-18A | 0-13.5A | 0-10A | |
|
rated power |
480W | 480W | 480W | 480W | 486W | 480W | |
|
Wavelength and noise |
240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | |
|
DC voltage range |
±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
|
Setting, rise time |
150ms,50ms,20ms/230VAC. | ||||||
|
input |
voltage range | 90~263VAC,47~63Hz,125~370VDC | |||||
|
alternating current |
7A/115VAC 3.5A/230VAC | ||||||
|
efficiency |
83% | 83% | 84% | 84% | 85% | 86% | |
|
Inrush current |
Cold start 36A/230VAC | ||||||
|
leakage current |
<3.5mA/240VAC | ||||||
|
Power factor (Typ.) |
PF>0.95/230VAC | ||||||
|
protect |
overload | 110~135% rated output power |
|||||
| Protection type: Hiccup mode, automatically restored after troubleshooting |
|||||||
|
overvoltage |
13~17V | 18~20V | 28~30V | 31~32V | 43~45V | 56~58V | |
| Protection type: Hiccup mode, automatically restored after troubleshooting |
|||||||
|
overtemperature |
Internal temperature>10, starting fan ≤ 45C, fan stop>85C, starting overheating | ||||||
| Protection type: Turn off o/p voltage, automatically restore after temperature drop | |||||||
|
environment
|
Working temperature and humidity |
-10℃~+60℃; 20% to 90% RH (see "Derating Curve") | |||||
|
Storage temperature and humidity
|
-20℃~+85℃; 10% to 95% RH without condensation | ||||||
|
vibration |
10~500Hz,2G, 10 minutes/1 cycle, with a cycle of 60 minutes, along the X, Y, and Z axes respectively | ||||||
|
safety |
withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
|
Isolation resistor |
I/P-O/P:I/P-FG,O/P-FG:100M Ohms/500VDC | ||||||
|
EMC |
safety standards |
满足 UL1012 UL60950-1 CB(IEC60950-1) | |||||
|
EMC emission |
C满足 EN55022,EN55024,CLASS B | ||||||
|
other |
size |
1.8kg 170*120*93(L*W*H) | |||||
|
packaging |
1.8kg/8pcs/15.5kg/0.027 cubic meters | ||||||
All parameters not specifically mentioned are measured at 230VAC input, rated load, and 25C ambient temperature
Measurement of ripple and noise at a bandwidth of 20MHz using a 12 "twisted pair terminal and parallel capacitors of 0.1uf and 47uf
3. Tolerance: including setting tolerance, line adjustment, and load adjustment.