Brief description: Our company produces, sells, and maintains the MR503C magnetic grid ruler reading head, which is mainly suitable for on-site installation services in Changzhou, Suzhou, Wuxi, Jiangyin, Shanghai, Yangzhou, and other places. It is also sold nationwide, such as Jiangsu, Zhejiang, Anhui, Shandong, Fujian, Guangdong, Guangxi, Hubei, Henan, Beijing, Tianjin, Heilongjiang, and other places. The after-sales service of the magnetic grid ruler manufacturer ensures that you can purchase with peace of mind. Bulk purchases offer more favorable prices.
MR503C magnetic grid rulerreading headCharacteristics and performance
1. Non contact sensing method to detect rotation position and speed, without considering mechanical wear and tear
2. The reaction speed can reach20m/秒
3. Resolution can reach0.001mm
4. The system accuracy is±0.01mm/m
5. LED intelligent status display
6. The built-in sensor head has a small volume and is suitable for small installation spaces. And it adopts a high protection level design (IP67), which can be used in harsh environments such as oil pollution, cutting, vibration, etc
7. In industrial applications, it can avoid the sensitivity of general optical environmental pollution and increase the long-term stability of the system
MR503C magnetic grid ruler reading headScope of application:
Measurement of lines, speeds, and positioning in machining centers, PVC cutting machines, wood cutting machines, lathes, milling machines, drilling machines, grinding machines, metal sheet processing machines, stone bridge cutting machines, laser welding machines, bending machines, spark machines, robot material handling, glass processing, linear motors, and other applications,Magnetic grid ruler manufacturerResponsible for after-sales service.
Wiring Definition:
The standard packaging is 3m bare wire output, with an outer diameter of OD5.0mm for the outgoing line
output definition |
Digital Display Meter |
PLC |
Vcc |
DC+5V/DC+24V |
DC+24V |
GND |
DC0V |
DC0V |
A+ |
A |
A |
A- |
/A |
empty |
B+ |
B |
B |
B- |
/B |
empty |
Z+ |
Z |
Z |
Z- |
/Z |
empty |
shielded wire |
shielded wire |
shielded wire |
Electrical performance of the reading head:
project |
definition |
Voltage VCC (DCV) |
5V+5%/24V±5% |
resolution |
1um/2.5um/5um/10um25um/50um/100um |
current consumption |
≤50ma |
Voltage level output |
≥2.5V |
Voltage level output |
≤0.5v |
Output signal type |
RS 422A |
Corresponding frequency |
250KHZ |
A. B phase angle difference |
≤90±25° |
Reading head sensing distance |
Max.2mm |
Operating Temperature |
-20~+80℃ |
Reading head protection level |
IP67 |
Reading head weight |
25±5 |
Installation of magnetic grid ruler:
Stick the magnetic grid ruler tape onto the machine tool
Thin tape must be adhered to a clean, dry, and flat surface. A typical cleaning agent is a mixture of 50% alcohol and 50% water or heptane (please note the manufacturer's instructions regarding contact with such solvents) On surfaces such as copper and brass, it should be ensured that the surface is clean and free of any oxide layer
Adhesive surface
After the tape is bonded to the surface, it directly generates adhesive force, and applying appropriate pressure has a better effect
Magnetic grid ruler bonding temperature
The bonding temperature of the magnetic grid ruler ranges from+21 ° C to 38 ° C. If the temperature is 11 ° C or lower, the adhesive will become too hard and the bonding force will be insufficient. Under correct application, the bonding force can be guaranteed even at temperatures below zero. Bonding force after 72 hours of bonding