1、 Characteristics of manual ball valve
1The fluid resistance is small, and its resistance coefficient is equal to that of a pipe segment of the same length.
2Simple structure, small size, and light weight.
3Tight and reliable, plastic is widely used as the sealing surface material for ball valves, with good sealing performance, and has also been widely used in vacuum systems.
4Easy to operate, quick opening and closing, from fully open to fully closed, just rotate90°Easy to control from a distance.
5Easy to maintain, manual ball valves have a simple structure, and the sealing rings are generally movable, making disassembly and replacement relatively convenient.
6When fully open or fully closed, the sealing surfaces of the ball and valve seat are isolated from the medium, and when the medium passes through, it will not cause erosion of the valve sealing surface.
7Widely applicable, with diameters ranging from a few millimeters to several meters, suitable for applications from high vacuum to high pressure.
2、 Manufacturing standards for manual ball valves
|
design and manufacturing |
structural length |
Flange size |
pressure-temperature |
experiment-inspection |
|
GB122237 |
GB12221 |
GB9113 JB79 |
GB9131 |
GB/T13927 JB/T9092 |
|
Nominal Pressure |
1.6 |
2.5 |
4.0 |
|
strength test |
2.4 |
3.8 |
6.0 |
|
Water seal test |
1.8 |
2.8 |
4.4 |
|
gas tightness test |
0.4-0.7 |
||
|
valve body |
ZG1Cr18Ni9Ti |
CF8 |
CF3 |
ZG1Cr18Ni12Mo2Ti |
CF8M |
CF3M |
|
|
sphere valve stem |
1Cr18Ni9Ti |
304 |
304L |
1Cr18Ni12Mo2Ti |
316 |
316L |
|
|
valve seat |
PolytetrafluoroethylenePTFEReinforced polytetrafluoroethylene with epoxy fibersPTFE+GlassDui Ju BenPPL |
||||||
|
shim |
PolytetrafluoroethylenePTFEstainless steel/flexible graphiteStainless Steel/flexible Graphiteserrated washerTooth Profile Gasket |
||||||
|
Valve stem seat |
PolytetrafluoroethylenePTFEstainless steel/flexible graphiteStainless Steel/Flexible Graphite |
||||||
|
filler |
PolytetrafluoroethylenePTFEEnhanced flexible graphiteEnhanced Flexible Graphite |
||||||
|
gland |
|
1Cr18Ni9Ti |
304 |
304L |
1Cr18Ni12Mo2Ti |
316 |
316L |
|
temperature |
-29~150(PolytetrafluoroethylenePTFE) -29~200(Adding fiberglass reinforced polytetrafluoroethylenePTFE+GLASS) -29~300(Dui Ju BenPPL) |
||||||
|
medium |
water steam oil products |
Nitric AcidNitric Acid |
Strong oxidizing medium |
Acetic acidAcetic Acid |
sulfonylureasUrea |
||
|
1.6MPa |
DN |
L |
D |
D1 |
D2 |
b |
n-φd |
H |
D0 |
|
raised face flange |
15 |
130 |
95 |
65 |
45 |
14 |
4-14 |
78 |
140 |
|
20 |
140 |
105 |
75 |
55 |
14 |
4-14 |
84 |
160 |
|
|
25 |
150 |
115 |
85 |
65 |
14 |
4-14 |
95 |
180 |
|
|
32 |
165 |
135 |
100 |
78 |
16 |
4-18 |
150 |
250 |
|
|
40 |
180 |
145 |
110 |
85 |
16 |
4-18 |
150 |
300 |
|
|
50 |
200 |
160 |
125 |
100 |
18 |
4-18 |
170 |
350 |
|
|
65 |
220 |
180 |
145 |
120 |
20 |
4-18 |
195 |
350 |
|
|
80 |
250 |
195 |
160 |
135 |
20 |
8-18 |
215 |
400 |
|
|
100 |
280 |
215 |
180 |
155 |
20 |
8-18 |
250 |
500 |
|
|
125 |
320 |
245 |
210 |
185 |
22 |
8-18 |
265 |
600 |
|
|
150 |
360 |
280 |
240 |
210 |
24 |
8-23 |
270 |
800 |
|
|
200 |
400 |
335 |
295 |
265 |
26 |
12-23 |
330 |
1200 |
|
|
2.5MPa |
15 |
130 |
95 |
65 |
45 |
16 |
4-14 |
103 |
140 |
|
raised face flange RF |
20 |
140 |
105 |
75 |
55 |
16 |
4-14 |
112 |
160 |
|
25 |
150 |
115 |
85 |
65 |
16 |
4-14 |
123 |
180 |
|
|
32 |
165 |
135 |
100 |
78 |
18 |
4-18 |
150 |
250 |
|
|
40 |
180 |
145 |
110 |
85 |
18 |
4-18 |
156 |
300 |
|
|
50 |
200 |
160 |
125 |
100 |
20 |
8-18 |
172 |
350 |
|
|
65 |
220 |
180 |
145 |
120 |
22 |
8-18 |
197 |
350 |
|
|
80 |
250 |
195 |
160 |
135 |
22 |
8-23 |
222 |
400 |
|
|
100 |
280 |
230 |
190 |
160 |
24 |
8-23 |
253 |
500 |
|
|
125 |
320 |
270 |
220 |
188 |
28 |
8-25 |
275 |
600 |
|
|
150 |
360 |
300 |
250 |
218 |
30 |
8-25 |
286 |
800 |
|
|
200 |
400 |
360 |
310 |
278 |
34 |
12-25 |
340 |
1200 |
|
4.0MPa |
DN |
L |
D |
D1 |
D2 |
D6 |
b |
n-φd |
H |
D0 |
|
Concave convex flange |
15 |
130 |
95 |
65 |
45 |
40 |
16 |
4-14 |
103 |
140 |
|
20 |
140 |
105 |
75 |
55 |
51 |
16 |
4-14 |
112 |
160 |
|
|
25 |
150 |
115 |
85 |
65 |
58 |
16 |
4-14 |
123 |
160 |
|
|
32 |
180 |
135 |
100 |
78 |
66 |
18 |
4-18 |
150 |
250 |
|
|
40 |
200 |
145 |
110 |
85 |
76 |
18 |
4-18 |
156 |
250 |
|
|
50 |
220 |
160 |
125 |
100 |
88 |
20 |
4-18 |
172 |
350 |
|
|
65 |
250 |
180 |
145 |
120 |
110 |
22 |
8-18 |
197 |
350 |
|
|
80 |
280 |
195 |
160 |
135 |
121 |
22 |
8-18 |
222 |
450 |
|
|
100 |
320 |
230 |
190 |
160 |
150 |
24 |
8-23 |
253 |
450 |
|
|
125 |
400 |
270 |
220 |
188 |
176 |
28 |
8-25 |
275 |
600 |
|
|
150 |
400 |
300 |
250 |
218 |
204 |
30 |
8-25 |
286 |
800 |
|
|
200 |
550 |
375 |
320 |
282 |
260 |
38 |
12-30 |
340 |
1200 |
|
|
6.4MPa |
15 |
165 |
105 |
75 |
55 |
40 |
18 |
4-14 |
105 |
140 |
|
Concave convex flange |
20 |
190 |
125 |
90 |
68 |
51 |
20 |
4-18 |
125 |
160 |
|
25 |
216 |
135 |
100 |
78 |
58 |
22 |
4-18 |
135 |
250 |
|
|
32 |
229 |
150 |
110 |
82 |
66 |
24 |
4-23 |
150 |
350 |
|
|
40 |
241 |
165 |
125 |
95 |
76 |
24 |
4-23 |
165 |
350 |
|
|
50 |
292 |
175 |
135 |
105 |
88 |
26 |
4-23 |
175 |
450 |
|
|
65 |
330 |
200 |
160 |
130 |
110 |
28 |
8-23 |
200 |
450 |
|
|
80 |
356 |
210 |
170 |
140 |
121 |
30 |
8-23 |
210 |
600 |
|
|
100 |
432 |
250 |
200 |
168 |
150 |
32 |
8-25 |
250 |
700 |
|
|
125 |
508 |
295 |
240 |
202 |
176 |
36 |
8-30 |
295 |
1100 |
|
|
150 |
559 |
340 |
280 |
240 |
204 |
38 |
8-34 |
340 |
1500 |
7、 Maintenance and repair of manual ball valves
1Before repairing the manual ball valve, release the pressure on the pipeline and fully open the ball valve. After disconnecting the power or gas source, detach the actuator from the bracket.
2Before starting the operation, it is necessary to ensure that the pressure in the upstream and downstream pipelines of the ball valve is relieved.
3The steps and procedures for disassembling and reassembling.
4The cleaning agent should be compatible with the rubber parts, plastic parts, metal parts, and working medium in the manual ball valve. When the medium is gas, metal parts can be cleaned with gasoline, while non-metal parts should be cleaned with purified water or alcohol.
5Decomposed parts can be cleaned by immersion washing, while non decomposed parts can be wiped with a clean silk cloth soaked in cleaning agent. Cleaning the toy must remove all grease, dirt, adhesive buildup, dust, etc. adhered to the wall surface.
6Non metallic parts should not be soaked in cleaning agents for a long time after use Avoid expansion and corrosion.
7After cleaning, it can be wiped dry with a new silk cloth. After the wall cleaning agent evaporates completely, assembly can be carried out. At this time, attention should be paid not to leave it for a long time, otherwise it will cause rusting and dust pollution problems.
8After cleaning and drying all parts, lubricate metal materials, rubber parts, and plastic parts with grease. When the medium is gas, for example, special221 grease. Apply a thin layer of lubricating grease on the surface of the seal installation groove, the rubber seal, the sealing surface of the valve stem, and the friction surface.
9During assembly, metal debris, fibers, dust, other impurities, foreign objects, and other contaminants are not allowed to remain on the parts or enter the internal cavity.
Ordering Notice:
1、 ①Q41FManual ball valve product name and model ②Q41FDoes valve ③ come with accessories for us to correctly select for you.
2、 If the manual ball valve model has already been selected by the design unit, please follow the instructionsQ41FThe manual ball valve model can be ordered directly from our Voto Valve Sales Department.
3、 When the usage is very important or the environment is complex,Please provide design drawings and detailed parameters as much as possible, and our Voto valve experts will review and control them for you.
Dear customer:
Welcome to visit our websiteFirst of all, thank you for your interest in our Voto valves. If you have any suggestions or questions about our products or services, please contact us immediately! We will do our best to provide you with high-quality service!!!