The connection form of vacuum isolation gate valve is divided into flange and welding, and there are two driving modes: manual and electric. This vacuum isolation gate valve is suitable for working temperature≤425℃and≤550℃As an opening and closing device on pipelines with working media such as water, steam, or air; Especially suitable for steam turbine condensation and vacuum negative pressure systems in thermal power plants, it plays a role in vacuum isolation and sealing.
Structural characteristics
1Designed a vacuum sealed structure packing chamber to isolate the system from the atmosphere and have good environmental performance.
2The materials are carefully selected and meet relevant national and international standards, with high overall quality.
3The advanced and reasonable pairing of sealing pairs improves sealing performance and has a long service life.
4The opening and closing components adopt parallel gate bi-directional elastic sealing, with low friction, easy opening and closing, convenient maintenance, reliable sealing, and excellent performance.
5The valve stem has undergone quenching and surface nitriding treatment, exhibiting excellent corrosion resistance, abrasion resistance, and wear resistance.
6The flange gasket is made of composite material, which has a large expansion coefficient, good air tightness performance, and ensures reliable isolation between the system and the atmosphere.
Vacuum isolation gate valve test pressure
|
nominal pressure |
test pressure/MPaSealtest |
||
|
Shell strength test |
Back Seal test |
Sealing test |
|
|
1.0 |
1.5 |
1.1 |
1.1 |
|
1.6 |
2.4 |
1.8 |
1.8 |
|
2.5 |
3.8 |
2.8 |
2.8 |
|
4.0 |
6.O |
4.4 |
4.4 |
|
6.4 |
8.6 |
7.O |
7.0 |
|
1O. O |
15.O |
11.O |
11.O |
Scope of use of vacuum isolation gate valve
|
product type |
Applicable Medium |
Temperature/℃ |
|
NKZ41H |
Water, steam, air |
≤425 |
|
NKZ41H(Y) |
Water, steam, air |
≤550 |
Main component materials of vacuum isolation gate valve
|
Part name |
Valve body and valve cover |
valve stem |
Ram |
Sealing surface |
stem nut |
filler |
fastener |
|
NKZ44H |
WCB |
2Crl3 |
25 |
H: Alloy steel |
Aluminum bronze |
Expanded composite graphite |
High quality carbon steel |
|
NKZ44 |
chromium molybdenum steel |
20CrlMo1VA |
chromium molybdenum steel |
Y: Hard alloy |
chromium molybdenum steel |
Main dimensions and weight of vacuum isolation gate valve
|
Nominal Diameter |
nominal pressure |
Main external dimensions and connection dimensions/mm |
valve |
Attached flange dimensions/mm |
||||||||||
|
L |
H |
D |
D1 |
D2 |
b |
f |
z-d |
W |
h |
D0 |
Dn |
|||
|
50 |
1.O |
250 |
345 |
160 |
125 |
1OO |
16 |
3 |
4-18 |
250 |
28 |
45 |
49 |
58 |
|
65 |
270 |
395 |
180 |
145 |
120 |
18 |
3 |
4-18 |
250 |
40 |
48 |
64 |
75 |
|
|
80 |
280 |
425 |
195 |
160 |
135 |
20 |
3 |
4-18 |
300 |
55 |
50 |
78 |
97 |
|
|
100 |
300 |
51O |
215 |
180 |
155 |
20 |
3 |
8-18 |
300 |
72 |
52 |
96 |
110 |
|
|
125 |
325 |
570 |
245 |
21O |
185 |
22 |
3 |
8-18 |
350 |
106 |
60 |
120 |
136 |
|
|
150 |
350 |
725 |
280 |
240 |
21O |
24 |
3 |
8-18 |
350 |
146 |
60 |
145 |
163 |
|
|
200 |
400 |
820 |
335 |
295 |
265 |
26 |
3 |
8-18 |
400 |
220 |
62 |
202 |
223 |
|
|
250 |
450 |
890 |
390 |
350 |
320 |
28 |
3 |
12-23 |
400 |
315 |
62 |
225 |
278 |
|
|
300 |
500 |
1070 |
440 |
400 |
368 |
28 |
3 |
12-23 |
450 |
398 |
65 |
303 |
330 |
|
|
350 |
550 |
1320 |
500 |
460 |
428 |
30 |
4 |
16-23 |
550 |
530 |
65 |
351 |
382 |
|
|
400 |
600 |
1450 |
565 |
515 |
482 |
32 |
4 |
16-25 |
550 |
690 |
65 |
398 |
432 |
|
|
450 |
650 |
1560 |
615 |
565 |
532 |
32 |
4 |
20-25 |
600 |
870 |
70 |
460 |
485 |
|
|
500 |
700 |
1720 |
670 |
620 |
585 |
34 |
4 |
20-25 |
650 |
1080 |
78 |
500 |
535 |
|
|
600 |
800 |
1880 |
780 |
725 |
685 |
36 |
5 |
20-30 |
700 |
1350 |
90 |
600 |
636 |
|
|
700 |
900 |
2085 |
895 |
840 |
800 |
40 |
5 |
24-30 |
750 |
1950 |
90 |
690 |
726 |
|
|
800 |
1OOO |
2590 |
101O |
950 |
905 |
44 |
5 |
24-34 |
800 |
2500 |
106 |
790 |
826 |
|
|
50 |
1.6 |
250 |
345 |
160 |
125 |
1OO |
16 |
3 |
4-18 |
250 |
28 |
48 |
49 |
58 |
|
65 |
270 |
395 |
180 |
145 |
120 |
18 |
3 |
4-18 |
250 |
40 |
50 |
64 |
75 |
|
|
80 |
280 |
425 |
195 |
160 |
135 |
20 |
3 |
8-18 |
300 |
58 |
52 |
78 |
91 |
|
|
100 |
300 |
51O |
215 |
180 |
155 |
20 |
3 |
8-18 |
300 |
75 |
52 |
96 |
110 |
|
|
125 |
325 |
570 |
245 |
21O |
185 |
22 |
3 |
8-18 |
350 |
110 |
60 |
120 |
136 |
|
|
150 |
350 |
725 |
280 |
240 |
21O |
24 |
3 |
8-23 |
350 |
150 |
60 |
145 |
163 |
|
|
200 |
400 |
820 |
335 |
295 |
265 |
26 |
3 |
12-23 |
400 |
223 |
62 |
201 |
223 |
|
|
250 |
450 |
890 |
405 |
355 |
320 |
30 |
3 |
12-25 |
450 |
326 |
68 |
253 |
278 |
|
|
300 |
500 |
1070 |
460 |
41O |
375 |
30 |
3 |
12-25 |
550 |
432 |
70 |
303 |
330 |
|
|
350 |
550 |
1320 |
520 |
470 |
435 |
34 |
4 |
16-25 |
600 |
572 |
78 |
351 |
382 |
|
|
400 |
600 |
1450 |
580 |
525 |
485 |
36 |
4 |
16-30 |
650 |
740 |
90 |
398 |
432 |
|
|
450 |
650 |
1560 |
640 |
585 |
545 |
40 |
4 |
20-30 |
700 |
955 |
95 |
450 |
485 |
|
|
500 |
700 |
1720 |
705 |
650 |
608 |
44 |
4 |
20-34 |
750 |
1195 |
98 |
500 |
535 |
|
|
600 |
800 |
1880 |
840 |
770 |
718 |
48 |
5 |
20-41 |
800 |
1455 |
105 |
600 |
636 |
|
|
700 |
900 |
2085 |
g1O |
840 |
788 |
50 |
5 |
24-41 |
850 |
211O |
11O |
690 |
726 |
|
|
800 |
1OOO |
2590 |
1020 |
950 |
898 |
52 |
5 |
24-41 |
950 |
2630 |
115 |
790 |
826 |
|
Main dimensions and weight of vacuum isolation gate valve
|
Nominal Diameter |
nominal pressure |
Main external dimensions and connection dimensions/mm |
valve |
Attached flange dimensions/mm |
||||||||||
|
L |
H |
D |
D1 |
D2 |
b |
f |
Z-d |
W |
h |
DO |
Dn |
|||
|
50 |
25 |
250 |
345 |
160 |
125 |
100 |
20 |
3 |
4-18 |
250 |
30 |
48 |
49 |
64 |
|
65 |
270 |
395 |
180 |
145 |
120 |
22 |
3 |
8-18 |
250 |
43 |
52 |
66 |
82 |
|
|
80 |
280 |
425 |
195 |
160 |
135 |
22 |
3 |
8-18 |
300 |
60 |
55 |
78 |
95 |
|
|
1OO |
300 |
510 |
230 |
190 |
160 |
24 |
3 |
8-23 |
300 |
79 |
62 |
100 |
117 |
|
|
125 |
325 |
570 |
270 |
220 |
188 |
28 |
3 |
8-25 |
350 |
114 |
68 |
125 |
144 |
|
|
150 |
350 |
725 |
300 |
250 |
218 |
30 |
3 |
8-25 |
350 |
157 |
72 |
151 |
172 |
|
|
200 |
400 |
820 |
360 |
310 |
278 |
34 |
3 |
12-25 |
400 |
243 |
60 |
201 |
223 |
|
|
250 |
450 |
890 |
425 |
370 |
332 |
36 |
3 |
12-30 |
450 |
345 |
85 |
253 |
278 |
|
|
300 |
500 |
1070 |
483 |
430 |
390 |
40 |
4 |
16-30 |
550 |
455 |
92 |
303 |
330 |
|
|
350 |
550 |
1320 |
550 |
4g0 |
448 |
44 |
4 |
16-34 |
650 |
615 |
98 |
351 |
382 |
|
|
400 |
|
1450 |
610 |
550 |
505 |
48 |
4 |
16-34 |
700 |
7g4 |
115 |
398 |
432 |
|
|
450 |
650 |
1560 |
660 |
600 |
555 |
50 |
4 |
20-34 |
750 |
1018 |
115 |
450 |
483 |
|
|
500 |
700 |
1720 |
730 |
660 |
61O |
52 |
4 |
20-41 |
800 |
1250 |
120 |
498 |
535 |
|
|
600 |
800 |
1880 |
840 |
770 |
718 |
56 |
5 |
20-41 |
850 |
1528 |
130 |
598 |
636 |
|
|
700 |
900 |
2085 |
955 |
875 |
815 |
60 |
5 |
24-48 |
900 |
2265 |
140 |
688 |
726 |
|
|
800 |
1000 |
2590 |
1070 |
990 |
930 |
64 |
5 |
24-48 |
1000 |
2847 |
150 |
788 |
826 |
|
|
Nominal Diameter |
nominal pressure |
Main external dimensions and connection dimensions/mm |
valve |
Attached flange dimensions/mm |
||||||||||||
|
L |
H |
D |
D1 |
D2 |
b |
f |
D6 |
f2 |
z-d |
W |
h |
DO |
Dn |
|||
|
50 |
4.O |
250 |
345 |
160 |
125 |
100 |
20 |
3 |
88 |
4 |
4-18 |
300 |
35 |
48 |
48 |
64 |
|
65 |
270 |
395 |
180 |
145 |
120 |
22 |
3 |
11O |
4 |
8-18 |
300 |
49 |
52 |
66 |
82 |
|
|
80 |
280 |
425 |
195 |
160 |
135 |
22 |
3 |
121 |
4 |
8-18 |
350 |
65 |
58 |
78 |
95 |
|
|
100 |
300 |
510 |
230 |
190 |
160 |
24 |
3 |
150 |
4.5 |
8-23 |
350 |
87 |
68 |
100 |
117 |
|
|
125 |
325 |
570 |
270 |
220 |
188 |
28 |
3 |
176 |
4.5 |
8-25 |
400 |
124 |
68 |
125 |
144 |
|
|
150 |
350 |
725 |
300 |
250 |
218 |
30 |
3 |
204 |
4.5 |
8-25 |
400 |
172 |
72 |
151 |
172 |
|
|
200 |
400 |
820 |
375 |
320 |
282 |
38 |
3 |
260 |
4.5 |
12-30 |
450 |
275 |
88 |
19g |
223 |
|
|
250 |
450 |
890 |
445 |
385 |
345 |
42 |
3 |
313 |
4.5 |
12-34 |
550 |
392 |
102 |
251 |
278 |
|
|
300 |
500 |
1070 |
51O |
450 |
408 |
46 |
4 |
364 |
4.5 |
16-34 |
650 |
515 |
116 |
301 |
330 |
|
|
350 |
550 |
1320 |
570 |
510 |
465 |
52 |
4 |
422 |
5 |
16-34 |
750 |
684 |
120 |
34g |
382 |
|
|
400 |
600 |
1450 |
655 |
585 |
535 |
58 |
4 |
474 |
5 |
16-41 |
850 |
902 |
142 |
396 |
432 |
|