Overview
The NOVEC gas analyzer is based on ultra sensitive cantilever beam enhanced photoacoustic spectroscopy detection technology, combined with quantum cascade laser (QCL) light source, and operates on the mid infrared basic spectral absorption peak of NOVEC. The combination of these two provides an ultra-high level of stability, with recalibration cycles lasting several months or even years, greatly reducing overall holding costs.
Product Details

Testing requirements:

NOVEC gas analyzerCommonly used as a fire extinguishing agent, its concentration must be monitored in real time after extinguishing the fire to ensure the safe entry of personnel into the fire scene and the effectiveness of firefighting.

NOVEC气体分析仪

Technical application:

DKG ONE-NOVEC gas analyzerIt is based on ultra sensitive cantilever beam enhanced photoacoustic spectroscopy detection technology, combined with quantum cascade laser (QCL) light source, working on the mid infrared basic spectral absorption peak of NOVEC. The combination of these two provides an ultra-high level of stability, with recalibration cycles lasting several months or even years, greatly reducing overall holding costs.

NOVEC气体分析仪NOVEC气体分析仪

Ultra sensitive optical cantilever microphone

NOVEC gas analyzerTechnical advantages:

The adopted photoacoustic spectroscopy technology has high sensitivity and rapid response;

Direct absorption measurement without drift;

Low sample size, no consumables required;

Wide dynamic range, sub ppb level detection lower limit;

Independent operating system with built-in gas exchange pump;

Stable operation, long recalibration interval (several months).


NOVEC气体分析仪


NOVEC gas analyzerTechnical Principle

Working principle: Infrared photoacoustic spectroscopy

Ultra sensitive optical microphone, based on micro motor cantilever sensor, combined with laser interferometer to measure the micro motion of cantilever beam

Light source: distributed feedback quantum cascade laser

The temperature of the sample pool remains stable at 50 ℃


NOVEC gas analyzerdetection parameters

Response time: Depending on the channel integration time (C.I.T.) and gas replacement cycle, typically ranging from 3 seconds to 3 minutes

Detection limit: 0.1ppb

Dynamic Range: Typical Level 5 (100000 times detection limit)

Repeatability: Measurement values less than 1% at standard concentrations under working conditions

Accuracy: depends on the accuracy of the calibration concentration standard gas, typically 2-5%

Temperature stability: No impact within the working temperature range

Pressure stability: No impact within the pressure working range


NOVEC gas analyzerGeneral

19 "3 U industrial chassis, suitable for all desktop or rack mounted fixed installations

尺寸: 48.4cm W x 13.9cm H x 44cm D(19.1 In W x 5.5 in H x 17.3 in D)

Weight: Approximately 13kg

Embedded computer with built-in 7 "front display

The data storage capacity is sufficient for continuous monitoring for at least one year

Total gas production: 10-30ml

The rear panel has four gas interfaces, two of which are sampling interfaces, equipped with dust particle filters

Power supply:

Input voltage: 100-240VAC, 50-60 Hz

Input power: 100-200 W (depending on specific requirements)

Communication interfaces: Ethernet, USB

DKG ONE-NOVEC can be remotely controlled through a smartphone, tablet, computer, or another DKG ONE (upcoming)



NOVEC gas analyzerenvironment

Operating conditions

Temperature range: 0 ℃ to+49 ℃

Humidity: No condensation

Pressure: 750mbar~1050 mbar

Dust/water rating: IP20 (IEC 529)

Storage conditions

Temperature range: -20 ℃ to+60 ℃

Sample gas conditions

Temperature range: 0 ℃ to+49 ℃

Humidity: No condensation, maximum relative humidity of 80% at a temperature of 35 ° C

Linear decrease to 35% when the temperature reaches 49 ° C

Pressure: 750 mbar to 1050 mbar

Airflow: approximately 1L/min

Particles<1 μ m


NOVEC gas analyzerStandard:

Compliant with the Low Voltage Directive 2014/35/EU, EMC Directive 2004/108/EC, and ROHS 2 Directive 2011/65/EU