OXY-100 Extraction Oxygen Transmitter

NegotiableUpdate on 03/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The OXY-100 oxygen transmitter adopts the second-generation solid-state electrolyte oxygen measurement technology independently developed by Yingchuang Environment, which is used for real-time monitoring of high-temperature corrosive flue gas oxygen
Product Details

The OXY-100 oxygen transmitter is independently developed by Yingchuang EnvironmentThe second-generation solid-state electrolyte oxygen measurement technology is used for real-time monitoring of high-temperature corrosive flue gas oxygen.

The product featuresHigh measurement accuracy, strong corrosion resistance, stable and reliable performance.Solved the problem of garbage incinerationUnder harsh working conditionsoxygenPoor corrosion resistance of the analyzeruseShort lifespan, etcIndustry challenges.

satisfyTechnical requirements for online monitoring of flue gas oxygen in HJ75-2017 and HJ76-2017 standards.


1. Can be used for a long time in high temperature environments

2.Adopting self-developed technologySecond generation solid-state electrolyte oxygen measurement technology

3.sceneservice lifeLonger,corrosion-resistantperformancestronger

4. High precision temperature compensation to eliminate the influence of environmental temperature

5. Simple operation, long service life, and easy maintenance

6. Volume percentage output, meeting environmental testing requirements

7. Oxygen concentration can be calibrated at a single point on site to ensure measurement accuracy

8. Can be applied to the long-term measurement of oxygen concentration in highly corrosive conditions of garbage incineration


Measurement principle: Zirconia measurement principle

Detection range: 0-25VOL%

Measurement accuracy: ± 1% F.S

Repeatability: ± 1% F.S

Response time: T90<20S

Sampling method: Extract based

Installation method: Wall mounted installation

Sample gas temperature: 0-500 ℃

Pressure compensation: capable of external 4-20mA pressure signal automatic compensation

ElectricitySource: 24VDC 30W

Output interface: 4-20mA, 0-5V, 0-10V

Calibration method: on-site support for single point calibration

Calibration trigger: Supports two external calibration triggers