Automatic dosing for papermaking waste gas treatment:
Paper mills generate a large amount of acidic and alkaline waste gases during chemical pulping and bleaching processes. In the process of exhaust gas treatment, the spray tower circulating water tank sprays liquidPHThe value is constantly changing, which seriously affects the adsorption of acidic and alkaline waste gases. In order to ensure that the circulating liquid in the spray tower maintains the corresponding alkalinity(PHvalue in9.00~9.50)Our company's research and development of papermaking waste gasPHThe automatic dosing system can meet the requirements of paper acid and alkali waste gas treatment, achieve unmanned automatic dosing, facilitate enterprises to save labor costs, and meet environmental emission requirements. whenPHValue below9.00At high precisionPHsensorETP-60,Immediately send the model to the instrument panelPC-3300The instrument immediately controls the power supply of the dosing pump to start; whenPHabove9.50At this time, the instrument cuts off the power supply of the dosing pump. Repeat this process repeatedly to achieve automatic adjustment of the acidity and alkalinity of the biological adsorption tower.
Automatic dosing system for papermaking waste gasThe configuration list is as follows:
(1)PHController: Model:PC-3300Brand:eTime(ETECH),Function: With two sets of switch output,1group4-20mAoutput, onegroup485digital output.
(2)PHElectrode: Model:ETP-60Brand: Yitai(ETECH),PH:0.00-14.00Blue film high pollution resistant electrode.
(3)Installation accessories:1Meter long electrode protection sleeve (including1Meter long electrode protective sleeve, fixed bracket, junction box, protective head, sealing plug
(4)Standard solution:PH=6.86,250ml/Bottle;PH=4.01,250ml/Bottle.
(5)Automatic control electrical box;Outdoor rainproof type, with manual, automatic, and stop mode switching, double-layer door anti acid fog.
(6)Mechanical diaphragm metering pump: Model:EXB-60Brand:*(Excellent),Traffic:060L/H, pressure;2kg/cm2,
Resistant to no-load and acid and alkali.
(7)blender(Optional): Power0.55KWVoltage:380VAC,304Rod and blade or cast iron rubber.
(8)Dispensing bucket:PEThickening:200L/500L1000Loptional
This system is suitable for:papermakingAutomatic dosing of waste gas, chemical pulping waste gas, and papermaking bleaching waste gas、Waste gas from pulp making processAutomatic dosingWaste gas from bleaching processAutomatic dosingThePPAutomatic dosing for towers and spray towersWait.