Portable rapid biological toxicity analyzer


Portable rapid biological toxicity analyzer
Product Introduction
JC-FQ4typeToxicity analyzer is a toxicity detection system based on biosensing technology, which qualitatively and quantitatively detects the luminescence of luminescent bacteria during metabolism. It provides a fast and effective detection method for water quality and food toxicity status, which can quickly and accurately evaluate toxicity, and can provide scientific and reliable analysis results with just a few simple steps. Suitable for monitoring the toxicity of drinking water and food, as well as rapid detection of sudden water pollution incidents. It can also be used to monitor changes in hazardous substances in the pipeline network, as well as the relative toxicity of incoming and outgoing water in sewage treatment plants.
Measuring principle
The instrument uses luminescent bacterial reagents, which emit light during metabolism. When these bacteria are in a toxic environment caused by heavy metals and other organic and microbial substances, their emitted light is inhibited. The stronger the toxicity, the stronger the inhibitory effect on the metabolism of luminescent bacteria, and the more obvious the inhibition of luminescence. The toxicity of the sample can be quickly and accurately tested based on changes in its light intensity.
Performance Characteristics
High sensitivity, capable of monitoring very low concentrations
Can detect a wide range of pollutants
Chinese interface,Friendly and user-friendly
Fast and reliable,The results can be obtained in a few minutes
Portable and convenient,Suitable for outdoor on-site testing
No strict environmental conditions required, strong adaptability
Identify heavy metals and organic compounds
Luminescent bacteria can be stored for a long time
Technical Specifications
Detection Principle |
Using a microbial sensor (Vibrio fischeri) from the United StatesEPArecognize |
test mode |
ATPTheISO, screening |
inspect measure device |
Photomultiplier tube(PMT) |
spectral range |
300~650nm |
wave peak |
400nm |
Microbial detection limit |
10~15mol ATP |
Reading range |
0~1000000 RLU |
measure try pipe |
diameter12mm, height55mm |
Test Item |
Comprehensive toxicity |
Toxicity display results |
Relative luminous intensityICValue(%); Relative luminous quantity unit(RLU) |
Bacterial species |
Vibrio cholerae, Vibrio cholerae, Vibrio fischeri, Vibrio cholerae |
communication |
RS232CconnectPCSave measurement data asExcelFile(XPSystem) |
measure time |
0~99sOptional (to be selected)1sIncremental) |
store data |
1900number of groups |
ISOpattern |
Can be performed simultaneously4Group experiment, each group experiment can be set with time reminders separately |
Operating Temperature |
15~40℃ |
Operating Humidity |
10%~90%no condensation |
type |
Alkaline or charging (external charging) |
external power supply |
220V 50Hz |
electricity pool |
4sectionAAtype |
Rong quantity |
not less than2600mAh |
ruler inch |
320*170*180mm |
heavy quantity |
<2kg |
Main Configuration |
Host, luminescent bacterial reagent kit, freeze-dried bacterial powder containing Vibrio cholerae from Qinghai10Branch, resuscitation fluid diluent, osmotic pressure regulator, etc |
Qingdao Yuzhijia'an Environmental Protection provides complete product after-sales service