The radar water level gauge rangefinder emits extremely narrow microwave pulses from the water level gauge antenna, which propagate at the speed of light in space. When it encounters the surface of the measured medium, some of its energy is reflected back and received by the same antenna. The time interval between transmitting and receiving pulses is proportional to the distance from the antenna to the surface of the measured medium.
Product Details

radar water level gauge


modelJT-LD-24G

图片1.png



1. Product principle

Radar water level gauge rangefinderThe antenna emits extremely narrow microwave pulses, which propagate at the speed of light in space. When they encounter the surface of the measured medium, some of their energy is reflected back and received by the same antenna. The time interval between transmitting and receiving pulses is proportional to the distance from the antenna to the surface of the measured medium. Due to the propagation speed of electromagnetic waves *, it is difficult to confirm the time interval between the transmitted pulse and the received pulse, which is very small (nanosecond level),90Xseries26Gradar water level gaugeBy using a special demodulation technique, the time interval between the transmitted pulse and the received pulse can be accurately identified, thereby further calculating the distance between the antenna and the surface of the measured medium.

A. Range setting

B. Low level adjustment

C. High level adjustment

D. Blind area range


图片2.png

2. Application characteristics of water conservancy industry

Industry RecommendedRadar water level gauge, rangefinder, and meteradopted26GHzThe emission frequency has:

lSmall beam angle, concentrated energy, and stronger resistance to impactStrength greatly improves measurement accuracy and reliability

lThe antenna size is small, making it easy to install and install antenna protection devices such as dust covers

lLightweight approximately1KGEasy to install

lThe measurement range can reach up to70Meter, covering large reservoirs and other water level measurements

lMultiple output circuit interfaces and integration with acquisition systems

lUsing pulse working mode,radar water level gaugeExtremely low transmission power, no harm to human body and environment


The reference surface for measurement is the bottom surface of the thread or the sealing surface of the flange

Note: Use radarwaterTiming must ensure the highestliquidCannot enter the measurement blind zone (as shown in the figure)DThe area shown.

3Instrument Introduction


图片3.png


should Use: Rivers, lakes, and shallow waters

Measurement range: 30rice

Process connection: threadG1½ʺ A /support/flange

Process temperature: -40100

Process pressure: atmospheric pressure

essence Degree: ±3mm

Frequency range: 26GHz

Protection level: IP67 / IP65

Power supply:DC624V/four lines

DC 24V /two lines

Signal output:RS485/ModbusAgreement(6~24V DC

0mA/HartTwo lines(24V DC

On site display: optional

outside Shell: aluminium/plastic


图片4.png


should Use:Rivers, lakes, and shallow waters

Measurement range:70rice

Process connection:threadG1½ʺ A /support/flange

Process temperature:-40100

Process pressure: atmospheric pressure

essence Degree: ±10mm

Frequency range:26GHz

Protection level:IP67 / IP65

Power supply:DC6—24V/four lines

DC 24V /two lines

Signal output:RS485/ModbusAgreement(6~24V DC

4~20mA/HartTwo lines(24V DC

On site display: optional

outside Shell: Aluminum/plastic

4. Instrumentinstall

ØPreparation before installation Please pay attention to the following items to ensure that the instrument can be installed correctly:

Please reserve sufficient installation space.

Please avoid installation environments with strong vibrations.

ØIllustration and installation location

图片5.png

Radar and bracket installation diagram (1)


图片6.png

Radar and bracket installation diagram (II)

Note: When radar antennas emit microwave pulses, there is a certain emission angle. There shall be no obstacles between the lower edge of the antenna and the surface of the measured medium, as well as within the area radiated by the emitted microwave beam. Therefore, during installation, it is necessary to avoid obstructing facilities as much as possible, and if necessary, "false echo learning" should be carried out. When installing instruments, attention should also be paid to: the highest liquid level should not enter the measurement blind zone; the instrument must be grounded, and lightning protection measures should be added; outdoor shading and rainproof measures should be taken.

5electrical connection

power supply voltage

RS485/Modbus Power supply andModbusThe signal lines are separated and each uses a shielded cable. The specific power supply voltage range can be found in the technical data.

(420) mA/HART(Two wire system) The power supply and output current signal share a two core shielded cable. Please refer to the technical data for the specific range of power supply voltage. For intrinsic safety type, a safety barrier must be added between the power supply and the instrument.

connection method

RS485/ModbusThe wiring diagram is as follows:

图片7.png




24VThe two-wire wiring diagram is as follows:

图片8.png




safety guidance

Please comply with the requirements of the local electrical installation regulations!

Please comply with local regulations on personnel health and safety. All operations on the electrical components of instruments must be completed by professionals who have received formal training.

Please check the nameplate of the instrument to ensure that the product specifications meet your requirements.Please ensure that the power supply voltage meets the requirements on the instrument nameplateoneTo.

Protection level

This instrument * protection levelIP66/67Please ensure the waterproof performance of the cable sealing head. As shown in the figure below

图片9.png

How to ensure installation meetsIP67Requirement:

Please ensure that the sealing head is not damaged.

Please ensure that the cable is not damaged.

Please ensure that the cables used comply with the requirements of electrical connection specifications.

Before entering the electrical interface, bend the cable downwards to ensure that water does not flow into the housing, see

Please tighten the cable sealing head, see

Please seal the unused electrical interfaces with blind plugs, see

6Instrument debugging

radar water level gaugeThere are twoDebugging methods

⑴ Display/button

⑵ Upper computer debugging

display/Button

By displaying on the screen4Use one button to debug the instrument. The language of the debugging menu is optional. After debugging, it is usually only used for display, and the measured values can be read very clearly through the glass window.


LCD (Liquid Crystal Display)

② Button

图片10.png




7structural dimensions Unit mm

lwatch caseSize:

图片11.png

.Overall Dimensions

DC-6610

图片12.png

DC-6611

图片13.png

lConnection method:

²Standard bracket connection

²Connection with rain cover bracket

²thread G1½″Aconnect

²G1Installation base connection

图片14.png

8Technical Specifications

outside shell

Sealing between the outer shell and the outer shell cover silicone rubber

Shell window polycarbonate

grounding terminal stainless steel

power supply voltage

fourlinear system (624) V DC / RS485 Modbus /power consumption90mW

two linesmanufacture DC 24V / 4~20mA /power consumption0.75W

Allow ripple -<100Hz Uss<lV

- (100100K) Hz Uss<l0mV

cable parameters

Cable entry/plug M20xl.5cable entry

terminal block Cross-sectional area of conductor1.0mm²

output parameters

output signal RS485 Modbus / 4~20mA

communication protocol Modbus / Hart

resolution 1. 6u A

fault signal The current output remains unchanged;

20. 5mA

22mA

3.9mA

integration time 036)s, adjustable

blind spot Antenna end

Maximum measurement distance 908 30rice

909 70rice

Microwave frequency 26GHz

Measurement interval approximately1Seconds (depending on parameter settings)

adjust the time approximately1Seconds (depending on parameter settings)

display resolution 1mm

Working storage and transportation temperature (-4070

Process temperature (temperature of antenna section) (-40100

press atmospheric pressure

seismic resistance Mechanical vibration l0m/s² , (10150)Hz

9Instrument linearity

DC-6610

Launch angle Depends on antenna size

-76mm 12°

-96mm 8°

precision See the figure below

图片15.png

DC-6611

Launch angle Depends on antenna size

-76mm 12°

-96mm 8°

-121mm 6°

precision See the figure below

图片16.png

10. Productselection

Model:DC-6610

license

PStandard type (non explosion proof)

Process Connection/Materials

GthreadG1½ A /stainless steel304

NStandard bracket

MBracket with rain cover

H G1Install the base

YSpecial Customization

Antenna type/material

A horn antenna Φ76mm/stainless steel304

B horn antenna Φ96mm/stainless steel304

YSpecial Customization

seal/process temperature

V Ordinary seal/-40~100

electronic unit

VRS485/Modbus /four-wire system

W4~20mA / 24V DC two-wire system

shell/Protection level

L aluminium/IP67

G plastic /IP65

Cable incoming line

M M20 x l. 5

N ½ NPT

on-site display/programming

A belt

X without

Model:DC-6611

license

PStandard type (non explosion proof)

Process Connection/Materials

GthreadG1½ A /stainless steel304

NStandard bracket

MBracket with rain cover

H G1Install the base

YSpecial Customization

Antenna type/material

A horn antenna Φ96mm/stainless steel304

B horn antenna Φ121mm/stainless steel304

YSpecial Customization

seal/process temperature

V Ordinary seal/-40~100

electronic unit

VRS485/Modbus /four-wire system

W4~20mA / 24V DC two-wire system

shell/Protection level

L aluminium/IP67

G plastic /IP65

Cable incoming line

M M20 x l. 5

N ½ NPT

on-site display/programming

A belt

X without