| test scope | Suitable for twisted pair communication cables and power cables, 0-3m to 0-12km, 13 ranges, with graphic magnification function |
| multimeter | DC voltage 0 to 400V resolution 0.1V accuracy 1% ± 0.1V AC voltage 0 to 400V resolution 0.1V accuracy 2% ± 0.1V Battery 2 to 400V resolution 0.1V accuracy 1% ± 0.1V Resistance 0 to 1999.9 Ω, resolution 0.1 Ω, accuracy 0.2% ± 0.2 Ω 2K Ω to 10K Ω resolution 1 Ω accuracy 0.2% ± 1 Ω |
| insulation resistance | 50V/100V/250V/500V 0 to 49.99M Ω resolution 0.01M Ω accuracy 0.2% ± 0.01M Ω 50M Ω to 99.9M Ω resolution 0.1M Ω accuracy 4% 100M Ω to 999M Ω resolution 1M Ω accuracy 10% |
| Capacitance meter | 0 to 100M resolution 0.1M accuracy 2% ± 1M 100 to 1000M resolution 1M accuracy ± 3% 1000 to 10000M resolution 10M accuracy ± 5% 10000 to 50000M resolution 100M accuracy ± 8% |
| Online quality testing | Loop current 2 to 120mA resolution 0.1mA accuracy 5% ± 0.2mA Noise balance test 0 to 50dBrnC resolution 1dB accuracy ± 2dB Power interference 40 to 100dBrnC resolution 1dB accuracy ± 2Db Intervention loss 0 to 60Db frequency range 50HZ to 2MHz resolution 1dB Output levels 0 and -10 dB Chromaticity brightness interference 0 to 40Db frequency range 50HZ to 2MHz resolution 1dB Output levels 0 and -10 Db Frequency range: 50Hz to 2MHz Vertical balance 40 to 62dB frequency resolution 1dB accuracy ± 2dB Resistance: 100120135600900 Ω |
| power spectral density | |
| Dynamic range: -20dB/Hz to -140dB/HZ Frequency range: 20kHz to 2MHz Resolution: 10kHz Resistance: 100120135 Ω |
|
| Pulse Reflectometer (Inductive and Non Inductive Cables) (TDR) | |
| Maximum testing range | When the VOP of the working waveform is 99.0%, test for 19.4km When VOP is 60.0%, test 11.7km When the stored waveform VOP is 99.0%, test for 3.6km When VOP is 60.0%, test 2.2km The range varies depending on the VOP value |
| Horizontal resolution | Horizontal resolution<610 meters<0.07m when VOP is 99.0% When VOP is 30.0%, it is less than 0.02m >610 meters 0.1m (VOP is any value) |
| output signal | 2ns, 25ns, 500ns, 100ns, 1.5 μ s, 4.4 μ s, and 330 μ s |
| Vertical sensitivity: | >65dB |
| Output balance | Can vary between 80 Ω and 120 Ω |
| distance accuracy | ± 0.15 meters ± 0.01% of the reading |
| filter | Standard: 8 x, 50/60Hz Optional: 4 x, 8 x, 16 x, 32 x, 64 x, 128 x, 50/60Hz |
| Insulation fault location | |
| positioning range | 0 to 45km |
| Fault resistance range | 0 to 50M Ω |
| precision | 3-wire test ± 0.25% × DTS ± 0.4ohms 4-wire test ± 0.25% × DTS ± 0.25 ohms Kupffer test ± 1.0% × DTS ± 1ohm |
| 波形存储 | Standard 8 waveforms, 32 waveforms can be selected |
| Remote devices and oscillators | Analyze issues such as line pairing, open and closed circuits, and re bonding. |
| size | Excluding accessories and backpack, 160mm x 240mm x 60mm, weight 1.3kg Including accessories and backpack 198mm × 279mm × 165mm, weight 2.6kg Remote device: 216mm × 100mm × 40mm, weight 0.4kg Oscillator/Remote 230mm × 35mm × 25mm Weight 210g |
| Attachment (Standard) | instructions; 110V or 220V charger; Test cable, VOP card |
| (Optional) | Waveform storage, TDR noise filter; |