SN-200H series touch screen multi parameter water quality detection instrument using spectrophotometry and electrode method. Note: The touch screen multi parameter water quality detection instrument can be freely matched with the required indicators, integrating spectrophotometry and electrode method. Currently, it can support the detection of 40 indicators on the same device
Product Details

Spectrophotometric method+Electrode method SN-200Hseries

Touch screen multi parameter water quality detector

Note:Touch screen multi parameter water quality detectorCan be freely matched with the required indicators, integratedSpectrophotometric methodandElectrode methodCurrently, it can support40itemTested on the same device. Standard optional15Kongdan temperature zone touch screen digestion device or30Dual temperature zone touch screen digestion device with holesDue to testingDifferent indicators, selectedThe number of indicators variesThe prices are also differentPlease contact the sales personnel for an accurate quotation.

Optional indicators:COD(High and low dual range), ammonia nitrogen, total phosphorus, total nitrogen, nitrate nitrogen, nitrite nitrogen, turbidity, chromaticity, suspended solids, residual chlorine, total chlorine, chlorine dioxide, fluoride, sulfate, sulfide, phosphate, anilineCODManganese method (potassium permanganate index), barium, hexavalent chromium, total chromium, copper, iron, ferrous, nickel, zinc, dissolved oxygenPHTemperature, manganese, conductivityORPCadmium, magnesium, hardness, salinityTDSCobalt, ozone, cyanide.

1、 Product Introduction

This product adopts a touch sensitive design, with a fully Chinese operating interface, guided system operation, and automatic controlPIDFeatures include temperature control, color screen LCD display, automatic zeroing, direct reading of concentration, curve storage, and automatic printing. Dissolve colorimetric integrated tube design, pre storedCODThe curves of dozens of indicators such as ammonia nitrogen, total phosphorus, and total nitrogen make the entire detection process simple and convenient, making it easier for beginners to operate. It can be widely applied in fields such as environmental monitoring, scientific research water quality testing, production and emission monitoring and testing. This product adopts modular programming design, and can select single or multiple indicator detection indicator modules according to user needs. Users can upgrade and install new measurement indicators on this machine at any time according to their measurement needs during later use.

2、 Functional Features

1Color touch screen design, friendly human-machine dialogue interface, easy operation, direct reading of concentration;

2Using a digestion colorimetric integrated tube, the water sample determination process is simple, fast, safe, and the measurement results are accurate.

3Large capacity data storage and power-off protection design ensure that the instrument is not damaged and data records are not lost;

41point to7Point correction mode, automatically calculates slope, intercept, and correlation coefficient, with high measurement accuracy;

5Intelligent design for fault self diagnosis, making instrument management and maintenance simple and convenient;

6Strong anti-interference ability, suitable for industrial sites;

7Using semiconductor cold light source emitters, the light source has a long lifespan.

8Can connect to a computer to export measurement data, comes with a printer that can print measurement data and historical records.

9Low reagent usage, low operating costs, and strong anti-interference ability.

10The measurement range is broad, and measurement indicators can be freely combined according to needs.

11Pre stored standard curves can be retrieved for measurement at will, and self built measurement curves can also be created.

3、 System parameters

1Simultaneous digestion of sample quantity: optional15Branch (single temperature zone digestion device);30Branch (dual temperature zone digestion device);

2Measurement indicators:CODAmmonia nitrogen, total phosphorus, total nitrogen, etc. (freely combined according to user needs);

3Display mode: color LCD touch screen, Chinese operation interface;

4Colorimetric method: Colorimetric tube (digestion colorimetric integrated tube)

5Number of curves: adjustable100Measurement curve parameters;

6Calibration mode:1-7Point correction mode, automatically correcting curve values;

7Record storage: Can be stored30000The test results show that the data is protected from loss due to power failure;

8Fight Printing: Comes with a thermal printer;

9Data communication:RS232+USBInterface, which allows users to upload measurement results to a computer for statistical analysis;

10Environmental temperature:(5 ~ 40)℃; Environmental humidity: Relative humidity<85%(No condensation);

11External dimensions:300*220*120mm

12Working power supply:AC220V±10% / 50Hz

13Weight:2.8kg

14Indicator parameters:
1TheCODindicator

Measurement method: Rapid catalytic method (chromium method);

CODHigh and low range dual wavelength measurement:5~150mg/LLow wavelength;100~10000mg/L,High wavelength;

Measurement range:5 ~ 10000 mg/L(>1000 mg/LTime segmented measurement, over range dilution measurement);

Measurement error:5~100 mg/LAbsolute error≤±5 mg/L100 mg/L~5000 mg/LRelative error≤±5 %

Dissolving temperature:165 ± 1 Dissolving time:15minute;

Anti chlorine interference:[CL-]4000mg/ L

Choose a colorimetric dish:30mmOptical path length.

2ammonia nitrogen index

Measurement method: Nessler's colorimetric method;

Measurement range:0.01mg/L50mg/L(5 mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

3Total phosphorus index

Measurement method: Ammonium molybdate spectrophotometric method;

Measurement range:0.01mg/L24mg/L(0.75 mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Dissolving temperature:120 ± 1 Dissolving time:30minute;

Choose a colorimetric dish:30mmOptical path length.

4Total nitrogen index

Determination method: dissolution colorimetric method;

Measurement range:0-100 mg/L(Segmented measurement, over range dilution measurement);

Measurement error:≤±5 %

Dissolving temperature:125± 1 Dissolving time:30minute;

Choose a colorimetric dish:10mmOptical path length.

5Nitrate nitrogen index

Measurement method: colorimetric method;

Measurement range:0-100 mg/L(Segmented measurement, over range dilution measurement);

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

6Nitrite nitrogen index

Measurement method: colorimetric method;

Measurement range:0-6 mg/L(Segmented measurement, over range dilution measurement);

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

7color index

Measurement method: colorimetric method;

Measurement range:0500Hazen(500 HazenTime dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:30mmOptical path length.

8Turbidity index

Measurement method: spectrophotometric method;

Measurement range: 0400 NTU(100 NTUTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:30mmOptical path length.

9Suspended solids index

Measurement method: colorimetric method;

Measurement range:0500mg/L(500 mg/LTime dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:30mmOptical path length.

10Total chlorine index

Measurement method:N,N-Diethyl p-phenylenediamine photometric method;

Measurement range:0.01mg/L10mg/L(2mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

11Residual chlorine index

Measurement method:N,N-Diethyl p-phenylenediamine photometric method;

Measurement range:0.01mg/L10mg/L(2mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

12Chlorine dioxide index

Measurement method:N,N-Diethyl p-phenylenediamine photometric method;

Measurement range:0.01mg/L5mg/L(5mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

13Hexavalent chromium index

Measurement method: spectrophotometric method;

Measurement range:0.01mg/L5mg/L(1mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

14Sulfate index

Measurement method: spectrophotometric turbidity method;

Measurement range:5mg/L200mg/L(200 mg/LTime dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

15Phosphate index

Measurement method: Ammonium molybdate spectrophotometric method;

Measurement range:0.01mg/L24mg/L(0.75mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:30mmOptical path length.

16Sulfide index

Measurement method: methylene blue spectrophotometric method;

Measurement range:0.005mg/L12mg/L(1.5 mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

17Fluoride index

Measurement method: Fluorine reagent method;

Measurement range:0.01mg/L12mg/L(1.0mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

18Barium index

Measurement method: Tetraphenylborate sodium turbidity method;

Measurement range:0.01mg/L30mg/L(5 mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

19Aniline index

Determination method: Naphthalene ethylenediamine azo photometric method;

Measurement range:0.01mg/L20mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

20TheCODManganese method(Potassium permanganate index)indicator

Measurement method: Acid digestion spectrophotometry;

Measurement range:0-50mg/L (Dilution measurement with excess range)

Dissolving temperature:100 ± 1℃ Dissolving time:13minute;

Measurement error:≤±8 %

Choose a colorimetric dish:10mmOptical path length.

21Total chromium

Determination method: Potassium permanganate oxidation spectrophotometric method

Measurement range:0.0110mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

22Copper

Measurement method: Copper reagent spectrophotometric method

Measurement range:0.01~50mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

23Nickel

Determination method: Diketoxime spectrophotometric method

Measurement range:0.01~50mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

24Iron

Measurement method: Phenanthroline spectrophotometric method

Measurement range:0.01~50mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

25Ferrous iron

Measurement method: Phenanthroline spectrophotometric method

Measurement range:0.01~50mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

26Zinc

Measurement method: Zinc reagent spectrophotometric method

Measurement range:0.01~20mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

27Dissolved oxygen

Measurement range: Dissolved oxygen:0.020.0mg/L

Automatic temperature compensation range:0-40

Salinity calibration range:0.035.0mg/L

Indication error: Dissolved oxygen: ±0.3mg/LTemperature: ±0.5

Stability:3Within hours, not exceeding ±0.1mg/L

Repeatability: ≤0.15mg/L

Response time:<45second

Zero value error: ≤0.1mg/LSalinity compensation error: ≤2%

Environmental humidity: ≤90%

Ambient temperature040℃; Measure sample temperature:040

28ThePH

Measurement range:PH 014PH

Automatic temperature compensation range:0-60

Minimum display unit:0.01PH

Basic error:PH:≤±0.02PHTemperature: ±0.5

Stability:3Within hours, not exceeding ±0.01PH

Repeatability:0.01PH

Response time:<45second

Temperature compensation error: ≤0.01PH

Environmental humidity: ≤85%

Ambient temperature540

29Manganese

Measurement method: Potassium periodate spectrophotometric method;

Measurement range:0.01mg/L50mg/L(10 mg/LTime segmented measurement, over range dilution measurement)

Measurement error: ≤±5 %

Inspection basisGB11906-89

30Conductivity

Measurement method: electrode method

Measurement range:2~10000MS/cm

Measurement error: ≤±1%

31Temperature

Measurement range:-20-120

Measurement error: ±0.5

32TheORP

Measurement method: electrode method

Measurement range:-2000mV2000mV

Measurement error: ±0.1%

33Cadmium

Determination method: Cadmium reagent spectrophotometric method

Measurement range:0 0.5mg/L

Measurement error:≤±5 %

34Magnesium

Determination method: Chlorophosphonazo spectrophotometric method (USA)EPARecognized)

Measurement range:0~10mg/L(Dilution measurement with excess range)(Colorimetric tube measurement)0~10mg/LColorimetric dish measurement0~20mg/L

Measurement error:≤±5 %

Reagent:4Liquid reagents

35Hardness

Determination method: Chlorophosphonazo spectrophotometric method (USA)EPARecognized)

Measurement range:0~100mg/L(4mg/LIt can be measured in segments or dilutions)

Measurement error:≤±5 %

Reagent:3Liquid reagents

36Salinity

Measurement method: electrode method(GB11007-1989

Measurement range: Salinity:0-5%(segmented)

Automatic temperature compensation range:0-60
Basic error: Salinity:±0.02%(Range)0-1%);±0.05%(Range)1-5%); temperature±0.5
Response time:<45Seconds;
ambient humidity:≤85%
Ambient temperature5—40.

37TheTDS

Measurement method: electrode methodGB11007-1989
Measurement range:TDS0-50000mg/L; Temperature:0-60
Automatic temperature compensation range:0-60
Basic error:TDS±5%; Temperature:±0.5
Response time:<45Seconds;
ambient humidity:≤85%
Ambient temperature5—40.

38Cobalt

Measurement method:PADSpectrophotometry
Measurement range:0-5mg/L
Meet the standardsHJ550-2015

39Ozone

Measurement method: Indigo spectrophotometric method
Measurement range:0-1mgL
Meet the standardsGB/T 15437-1995

40Cyanide

Determination method: Isonicotinic acid-Pyrazolinone photometric method
Measurement range:0-0.5mg/L
Meet the standardsHJ484-2009