Welcome Customer !

Membership

Help

Qingdao Shangde Environmental Protection Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Qingdao Shangde Environmental Protection Technology Co., Ltd

  • E-mail

    admin@qdsunde.com

  • Phone

  • Address

    No. 4 Yuantou Road, Licang District, Qingdao City, Shandong Province

Contact Now

SN-200Y-40 portable multi parameter water quality analyzer

NegotiableUpdate on 02/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
SN-200Y-40 series field emergency portable multi parameter water quality testing instrument for digestion and measurement. Note: The multi parameter water quality testing instrument can be freely matched with detection indicators, and currently supports the detection of 40 indicators on the same device
Product Details

Dissolving and measuring integrated machine SN-200Y-40series

Outdoor emergency portable multi parameter water quality detector

Note:Multi parameter water quality detectorCan freely match detection indicators and currently supports40aThe indicators are tested on the same device. Due to testingDifferent indicators, selectedThe number of indicators variesThe prices are also differentPlease contact the sales personnel for an accurate quotation.

Optional indicators:COD(High and low dual range), ammonia nitrogen, total phosphorus, total nitrogen, nitrate nitrogen, nitrite nitrogen, turbidity, chromaticity, suspended solids, residual chlorine, total chlorine, chlorine dioxide, fluoride, sulfate, sulfide, phosphate, anilineCODManganese method (potassium permanganate index), barium, hexavalent chromium, total chromium, copper, iron, ferrous, nickel, zinc, dissolved oxygenPHTemperature, manganese, conductivityORPCadmium, magnesium, hardness, salinityTDSCobalt, ozone, cyanide.

1、 Product Introduction

This product combines colorimetric method with computer technology, applies microcomputer photoelectron colorimetric detection principle, eliminates human error, and improves measurement resolution. This product has automaticPIDThe instrument features temperature control, dual LCD display, AC/DC dual-use, automatic zero adjustment, concentration direct reading, curve storage, and automatic printing. It is easy to operate, with human-machine interactive operation, and users can apply this product without complex knowledge.

2、 Functional Features

1DoubleLCDDisplay, large screen LCD backlit display,240*128Dot matrix, Chinese operating interface, user-friendly programming.

2The measurement range is wide and can be switched according to the actual situation of the water sample.

3The measurement and digestion systems are designed separately, with independent power control, and the operation process can be carried out separately without affecting each other.

4Automatic temperature control system,PIDAdjust the technology to maintain a constant temperature during the digestion process.

51point to7Point correction mode, automatically calculates slope, intercept, and correlation coefficient.

6Intelligent design for fault self diagnosis makes instrument management and maintenance simple and convenient.

7The instrument has a built-in real-time clock, and measurement records are marked with measurement timestamps for easy statistics and queries.

8Large capacity data storage with power-off protection design ensures that the instrument is not easily damaged and data records are not easily lost.

9Strong anti-interference ability, suitable for industrial sites, and can be applied to monitor surface water and pollution sources.

10The instrument adopts a semiconductor cold light source emitter, optical circuit design, strong anti-interference ability, and long light source life.

11It has a data output interface that can be connected to a computer to transmit measurement data to the computer;

12The instrument comes with a thermal printer that can directly print measurement data and historical data;

13Portable box design, lightweight and easy to carry;

14The instrument is equipped with a built-in DC power supply and lithium battery power supply, which can achieve heating, digestion, and colorimetric determination of multiple batches of water samples;

3、 System parameters

1Simultaneous digestion quantity: ≤4Support;

2Temperature indication error: ≤±1℃;

3Uniformity of temperature field: ≤2℃;

4Error in digestion time indication: ≤±2%

5Curve parameters: adjustable100Measurement curve parameters;

6Calibration:1-7Point correction mode, automatically correcting curve values;

7Clock: Built in real-time clock, with a monthly cumulative error of less than10Seconds;

8Record storage: Can be stored10000Secondary measurement results;

9Printing: Comes with a built-in printer to print measurement results at any time;

10Communication method:RS232The measurement results can be uploaded to a computer for easy statistical analysis by users;

11Display:240*128Large blue backlit display with Chinese operating interface;

12Environmental temperature:(540)℃;

13Environmental humidity: Relative humidity<85%(No condensation);

14Working power supply:AC220V±10% / 50HzDC 16VLithium batteries;

15External dimensions:400*300*200mm

16Weight:8kg.

17Indicator parameters:

1.CODIndicator (requires digestion, integrated digestion device)

Measurement method: Rapid catalytic method (chromium method);

CODHigh and low range dual wavelength measurement:5~150mg/LLow wavelength;100~10000mg/L,High wavelength;

Measurement range:5 ~ 10000 mg/L(>1000 mg/LTime segmented measurement, over range dilution measurement);

Measurement error:5~100 mg/LAbsolute error≤±5 mg/L100 mg/L~5000 mg/LRelative error≤±5 %

Dissolving temperature:165 ± 1 Dissolving time:15minute;

Anti chlorine interference:[CL-]4000mg/ L

Choose a colorimetric dish:30mmOptical path length.

2.ammonia nitrogen index

Measurement method:Nessler's colorimetric method;

Measurement range:0.01mg/L50mg/L(5 mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

3.Total phosphorus index (to be digested, integrated digester)

Measurement method: Ammonium molybdate spectrophotometric method;

Measurement range:0.01mg/L24mg/L(0.75 mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Dissolving temperature:120 ± 1 Dissolving time:30minute;

Choose a colorimetric dish:30mmOptical path length.

4.Total nitrogen index (to be digested, integrated digester)

Determination method: dissolution colorimetric method;

Measurement range:0-100 mg/L(Segmented measurement, over range dilution measurement);

Measurement error:≤±5 %

Dissolving temperature:125± 1 Dissolving time:30minute;

Choose a colorimetric dish:10mmOptical path length.

5.Nitrate nitrogen index

Measurement method: colorimetric method;

Measurement range:0-100 mg/L(Segmented measurement, over range dilution measurement);

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

6.Nitrite nitrogen index

Measurement method: colorimetric method;

Measurement range:0-6 mg/L(Segmented measurement, over range dilution measurement);

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

7.color index

Determination methodcolorimetry;

Measurement range:0500Hazen(500 HazenTime dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:30mmOptical path length.

8.Turbidity index

Measurement method:Spectrophotometric method;

Measurement range: 0400 NTU(100 NTUTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:30mmOptical path length.

9.Suspended solids index

Determination methodcolorimetry;

Measurement range:0500mg/L(500 mg/LTime dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:30mmOptical path length.

10.Total chlorine index

Determination methodN,N-Diethyl p-phenylenediamine photometric method;

Measurement range:0.01mg/L10mg/L(2mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

11.Residual chlorine index

Determination methodN,N-Diethyl p-phenylenediamine photometric method;

Measurement range:0.01mg/L10mg/L(2mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

12.Chlorine dioxide index

Determination methodN,N-Diethyl p-phenylenediamine photometric method;

Measurement range:0.01mg/L5mg/L(5mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

13.Hexavalent chromium index

Determination methodSpectrophotometric method;

Measurement range:0.01mg/L5mg/L(1mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

14.Sulfate index

Determination method分光光度比浊法;

Measurement range:5mg/L200mg/L(200 mg/LTime dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

15.Phosphate index

Determination methodAmmonium molybdate spectrophotometric method;

Measurement range:0.01mg/L24mg/L(0.75mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:30mmOptical path length.

16.Sulfide index

Determination methodMethylene blue spectrophotometry;

Measurement range:0.005mg/L12mg/L(1.5 mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

17.Fluoride index

Determination methodFluorine reagent method;

Measurement range:0.01mg/L12mg/L(1.0mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

18.Barium index

Determination methodTetraphenylborate sodium turbidity method;

Measurement range:0.01mg/L30mg/L(5 mg/LTime segmented measurement, over range dilution measurement)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

19.Aniline index

Determination methodNaphthalene ethylenediamine azo photometryLaw;

Measurement range:0.01mg/L20mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

Choose a colorimetric dish:10mmOptical path length.

20. CODManganese method(Potassium permanganate index)indicator

Determination methodAcid digestion spectrophotometry

Measurement range:0-50mg/L (Dilution measurement with excess range)

Dissolving temperature:100 ± 1 Dissolving time:13minute;

Measurement error:≤±8 %

Choose a colorimetric dish:10mmOptical path length.

21Total chromium

Determination method: Potassium permanganate oxidation spectrophotometric method

Measurement range:0.0110mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

22Copper

Measurement method: Copper reagent spectrophotometric method

Measurement range:0.01~50mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

23Nickel

Determination method: Diketoxime spectrophotometric method

Measurement range:0.01~50mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

24Iron

Measurement method: Phenanthroline spectrophotometric method

Measurement range:0.01~50mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

25Ferrous iron

Measurement method: Phenanthroline spectrophotometric method

Measurement range:0.01~50mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

26Zinc

Measurement method: Zinc reagent spectrophotometric method

Measurement range:0.01~20mg/L(Dilution measurement with excess range)

Measurement error:≤±5 %

27Dissolved oxygen

Measurement range: Dissolved oxygen:0.020.0mg/L

Automatic temperature compensation range:0-40

Salinity calibration range:0.035.0mg/L

Indication error: Dissolved oxygen: ±0.3mg/LTemperature: ±0.5

Stability:3Within hours, not exceeding ±0.1mg/L

Repeatability: ≤0.15mg/L

Response time:<45second

Zero value error: ≤0.1mg/LSalinity compensation error: ≤2%

Environmental humidity: ≤90%

Ambient temperature040℃; Measure sample temperature:040

28ThePH

Measurement range:PH 014PH

Automatic temperature compensation range:0-60

Minimum display unit:0.01PH

Basic error:PH:≤±0.02PHTemperature: ±0.5

Stability:3Within hours, not exceeding ±0.01PH

Repeatability:0.01PH

Response time:<45second

Temperature compensation error: ≤0.01PH

Environmental humidity: ≤85%

Ambient temperature540

29Manganese

Measurement method: Potassium periodate spectrophotometric method;

Measurement range:0.01mg/L50mg/L(10 mg/LTime segmented measurement, over range dilution measurement)

Measurement error: ≤±5 %

Inspection basisGB11906-89

30Conductivity

Measurement method: electrode method

Measurement range:2~10000MS/cm

Measurement error: ≤±1%

31Temperature

Measurement range:-20-120

Measurement error: ±0.5

32TheORP

Measurement method: electrode method

Measurement range:-2000mV2000mV

Measurement error: ±0.1%

33Cadmium

Determination method: Cadmium reagent spectrophotometric method

Measurement range:0 0.5mg/L

Measurement error:≤±5 %

34Magnesium

Determination method: Chlorophosphonazo spectrophotometric method (USA)EPARecognized)

Measurement range:0~20mg/L(Dilution measurement with excess range)(Colorimetric tube measurement)0~10mg/LColorimetric dish measurement0~20mg/L

Measurement error:≤±5 %

Reagent:4Liquid reagents

35Hardness

Determination method: Chlorophosphonazo spectrophotometric method (USA)EPARecognized)

Measurement range:0~100mg/L(4mg/LIt can be measured in segments or dilutions)

Measurement error:≤±5 %

Reagent:3Liquid reagents

36Salinity

Measurement method: electrode method(GB11007-1989

Measurement range: Salinity:0-5%(segmented)

Automatic temperature compensation range:0-60
Basic error: Salinity:±0.02%(Range)0-1%);±0.05%(Range)1-5%); temperature±0.5
Response time:<45Seconds;
ambient humidity:≤85%
Ambient temperature5—40.

37TheTDS

Measurement method: electrode methodGB11007-1989
Measurement range:TDS0-50000mg/L; Temperature:0-60
Automatic temperature compensation range:0-60
Basic error:TDS±5%; Temperature:±0.5
Response time:<45Seconds;
ambient humidity:≤85%
Ambient temperature5—40.

38Cobalt

Measurement method:PADSpectrophotometry
Measurement range:0-5mg/L
Meet the standardsHJ550-2015

39Ozone

Measurement method: Indigo spectrophotometric method
Measurement range:0-1mgL
Meet the standardsGB/T 15437-1995

40Cyanide

Determination method: Isonicotinic acid-Pyrazolinone photometric method
Measurement range:0-0.5mg/L
Meet the standardsHJ484-2009