Welcome Customer !

Membership

Help

Sifang Optoelectronics Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Sifang Optoelectronics Co., Ltd

  • E-mail

    marketing@gassensor.com.cn

  • Phone

    13296672587

  • Address

    No. 3 Fenghuangyuan 3rd Road, Fenghuangyuan Industrial Park, Donghu New Technology Development Zone, Wuhan City

Contact Now

Side flow end expiratory carbon dioxide sensor

NegotiableUpdate on 03/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Sifang Optoelectronic Side Flow End Breath Carbon Dioxide Sensor is a CO2 sensor module designed based on the principle of infrared absorption spectroscopy, used to measure the concentration of CO2; Can be applied to devices such as monitors, nutritional metabolism analyzers, and exercise cardiorespiratory function testers. It has the advantages of high precision, good temperature characteristics, low power consumption, fast response time, compact appearance, and flexible integrated installation.
Product Details

旁流呼气末二氧化碳传感器


Side flow end expiratory carbon dioxide sensorProduct Introduction

Sifang OptoelectronicsSide flow end expiratory carbon dioxide sensorIt is a CO2 sensor module designed based on the principle of infrared absorption spectroscopy, used to measure the concentration of CO2; Can be applied to devices such as monitors, nutritional metabolism analyzers, and exercise cardiorespiratory function testers. It has the advantages of high precision, good temperature characteristics, low power consumption, fast response time, compact appearance, and flexible integrated installation.


Side flow end expiratory carbon dioxide sensorProduct Features

Autonomous NDIR sensor technology

EMI system anti electromagnetic interference

High signal-to-noise ratio and high detection accuracy

Volume based urine integrated installation

0.47W low power consumption

Side flow end expiratory carbon dioxide sensorTechnical Specifications

Detection Principle Non dispersive infrared technology (NDIR)
data output CO2 concentration (mmHg), end expiratory CO2, inhaled CO2, respiratory rate
Testing Scope 0 ~ 150 mmHg
resolution Resolution 0.1mmHg
detection accuracy 0 ~ 40 mmHg: ± 2 mmHg
41~70mmHg: True value ± 5%
71~100mm Hg: True value ± 8%
100~150mmHg; True value ± 10%
Respiratory rate range 0~150BPM
Respiratory rate accuracy ±1 breath
stability Short term drift: not exceeding 0.8mmHg (4H)
Long term drift: Maintain accuracy specifications within 120H
input voltage 5.00V (±5%)
average current <100mA
peak current <200mA
Initialization time Display within 15 seconds, full specification accuracy within 2 minutes (25 ℃)
compensation Air pressure: 400 mmHg -850mmHg
Working temperature and humidity Operation: 0C-55 ℃, 10-909% RH (non condensing)
Storage: -40 ° C~70 ° C,<90% RH (non condensing)
data communication TTL
lifespan ≥ 10 years
size 57.5mm*23.7mm*24mm