Welcome Customer !

Membership

Help

Dongguan Haoen Testing Instrument Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Small high and low temperature alternating test chamber

NegotiableUpdate on 02/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The small high and low temperature alternating test chamber can provide a simulated environment for users to inspect and test electronic and electrical components, spare parts, or experimental departments in related industries, providing * conditions for the accuracy and consistency (repeatability) of test data.
Product Details
  Small high and low temperature alternating test chamber
Introduction
Haoen seriesSmall high and low temperature alternating test chamberSuitable for quality testing of electronic, plastic products, electrical appliances, instruments, food, vehicles, metals, chemicals, building materials, aerospace, medical and other products. Specially test the heat resistance, cold resistance, dry resistance, and moisture resistance of various materials. This machine can choose Chinese or English LCD touch screen display, with simple operation, easy program editing, and user-friendly design. It can display complete system operation status related data, execution and program setting curves. If an abnormal situation occurs during operation, the screen will immediately sound an alarm, display the cause of the fault, and provide troubleshooting methods.
purpose
The constant temperature and humidity test chamber, also known as the environmental testing machine, tests the heat resistance, cold resistance, dry resistance, and moisture resistance of various materials. Suitable for use in factories such as electronics, electronics, food, vehicles, metals, chemicals, and building materials.
meet the standard
GB5170、2、3、5、6-95、GB 2423.1-89 (IEC68-2-1)、GB 2423.2-89 (IEC68-2-2)、GB/T 2423.3-93(IEC68-2-3)、GB/T423.4-93(IEC68-2-30)、GJB150.3(ML-STD0-810D)、GJB150.4(MIL-STD-810D)、GJB150.9-1986、GJB4.5-1983、GJB4.6-1983、GJB367.2-1987、GJB360.8-87、GB/T5170.2-96、GB/T5170.5-96、GB10592-93、GB10586-93 等
Main technical indicators

capacity

Inner box dimensions (width x height x depth)

Dimensions (width x height x depth)

Specification Model

temperature range

power supply wattage

23rise

300×300×250(mm)

500×1250×900(mm)

HE-WS-23A5

0~+150℃

Single phase three wire 220V 50HZ 4.5KW

HE-WS-23B5

-20~+150℃

Single phase three wire 220V 50HZ 5.0KW

HE-WS-23C5

-40~+150℃

Single phase three wire 220V 50HZ 5.5KW

HE-WS-23D5

-70~+150℃

Single phase three wire 220V 50HZ 6.5KW

64rise

400×400×400(mm)

600×1400×1100(mm)

HE-WS-64A5

0~+150℃

Single phase three wire 220V 50HZ 4.5KW

HE-WS-64B5

-20~+150℃

Single phase three wire 220V 50HZ 5.0KW

HE-WS-64C5

-40~+150℃

Single phase three wire 220V 50HZ 5.5KW

HE-WS-64D5

-70~+150℃

Single phase three wire 220V 50HZ 6.5KW

80rise

400×500×400(mm)

970×1360×970(mm)

HE-WS-80A8

0~+150℃

Single phase three wire 220V 50HZ 4.5KW

HE-WS-80B8

-20~+150℃

Single phase three wire 220V 50HZ 5.0KW

HE-WS-80C8

-40~+150℃

Single phase three wire 220V 50HZ 5.5KW

HE-WS-80D8

-70~+150℃

Single phase three wire 220V 50HZ 6.5KW

150rise

500×600×500(mm)

1070×1460×1070(mm)

HE-WS-150A8

0~+150℃

Single phase three wire 220V 50HZ 5.0KW

HE-WS-150B8

-20~+150℃

Single phase three wire 220V 50HZ 5.5KW

HE-WS-150C8

-40~+150℃

Single phase three wire 220V 50HZ 6.5KW

HE-WS-150D8

-70~+150℃

Single phase three wire 220V 50HZ 7.5KW

225rise

500×750×600(mm)

1070×1610×1170(mm)

HE-WS-225A8

0~+150℃

Single phase three wire 220V 50HZ 5.5KW

HE-WS-225B8

-20~+150℃

Single phase three wire 220V 50HZ 6.0KW

HE-WS-225C8

-40~+150℃

Single phase three wire 220V 50HZ 6.5KW

HE-WS-225D8

-70~+150℃

Single phase three wire 220V 50HZ 8.5KW

408rise

600×850×800(mm)

1170×1710×1270(mm)

HE-WS-408A8

0~+150℃

Three phase five wire 380 50HZ 6.0KW

HE-WS-408B8

-20~+150℃

Three phase five wire 380 50HZ 6.5KW

HE-WS-408C8

-40~+150℃

Three phase five wire 380 50HZ 7.0KW

HE-WS-408D8

-70~+150℃

Three phase five wire 380 50HZ 9.5KW

800rise

1000×1000×800(mm)

1550×1850×1300(mm)

HE-WS-800A8

0~+150℃

Three phase five wire 380 50HZ 6.5KW

HE-WS-800B8

-20~+150℃

Three phase five wire 380 50HZ 7.0KW

HE-WS-800C8

-40~+150℃

Three phase five wire 380 50HZ 7.5KW

HE-WS-800D8

-70~+150℃

Three phase five wire 380 50HZ 10.5KW

1000rise

1000×1000×1000(mm)

1550×1850×1470(mm)

HE-WS-1000A8

0~+150℃

Three phase five wire 380 50HZ 7.0KW

HE-WS-1000B8

-20~+150℃

Three phase five wire 380 50HZ 7.5KW

HE-WS-1000C8

-40~+150℃

Three phase five wire 380 50HZ 8.0KW

HE-WS-1000D8

-70~+150℃

Three phase five wire 380 50HZ 11.5KW

precision

temperature

±0.01

humidity

±0.1%R.H

volatility

temperature

±0.5

humidity

±2.0%R.H.

uniformity

temperature

±2.0

humidity

±3%R.H.

humidity range

20%RH~98%RH

heating rate

Average 3 ℃/min (non-linear, unloaded); Rising from room temperature+25 ℃ to+85 ℃ for about 20 minutes); Non standard specifications can be customized according to requirements

Cooling rate

Average 1 ℃/min (non-linear, unloaded); Reduce from room temperature+25 ℃ to -40 ℃ for about 65 minutes; Non standard specifications can be customized according to requirements

Inner box material

SUS 304Mirror-finished stainless steel

Outer box quality

SUS 201Stainless steel or cold steel plate with advanced spray coating treatment on the yarn surface

refrigeration system

Adopting French Taikang compressor, environmentally friendly refrigerants R404A and R23, finned condenser with heat dissipation evaporator

control system

Programmable touch screen temperature and humidity controller (880 or OYO8256)

protective device

Non fuse switch, compressor high voltage, overheating, overcurrent protection, overtemperature protection, fan overload protection, fuse, dry burn protector, water shortage alarm

Standard Configuration

2 sets of storage racks, 1 observation window, 1 testing hole, 4 casters, 1 humidification bucket, and 5 test wet cloths

Online software

232Or 485 interface connection, equipped with software CD and 1 set of data cable, optional USB interface

working principle
  



1. The constant temperature and humidity test chamber consists of two parts: temperature control (heating, cooling) and humidification. By installing a rotating fan at the top of the box, air is discharged into the box to achieve gas circulation and balance the temperature and humidity inside the box. The data collected by the temperature and humidity sensors built into the box is transmitted to the temperature and humidity controller (micro information processor) for editing and processing, and temperature and humidity control instructions are issued. This is achieved through the joint operation of the air heating unit, condenser tube, and water tank heating and evaporation unit.
2. The temperature regulation of a constant temperature and humidity box is achieved by using a built-in temperature sensor to collect data, which is then controlled by a temperature controller (miniature information processor). The air heating unit is connected to increase the temperature or the refrigeration solenoid valve is adjusted to lower the temperature inside the box, in order to achieve the desired temperature for control. The temperature regulation of a constant temperature and humidity chamber is achieved by using a built-in temperature sensor to collect data, which is then controlled by a humidity controller (miniature information processor). The heating element of the water tank is connected, and the humidity inside the chamber is increased by evaporating the water in the tank or adjusting the cooling solenoid valve to achieve dehumidification, in order to control the required humidity.
3. The constant temperature and humidity chamber is equipped with multiple protective measures; The temperature system is equipped with an over temperature protector under the maximum safe allowable temperature conditions that can be set. The air heating element can automatically power off when the rotating fan stops; The humidification system can stop supplying power as the water level in the humidification tank decreases; The refrigeration system also stops working as the temperature of the box rises (over 40 ℃) or the humidity increases.
Environmental conditions for use
Temperature: 5 ℃~+35 ℃ (average temperature within 24 hours ≤ 28 ℃);
Relative humidity: ≤ 85% RH;
Air pressure: 86KPaa~106KPaa;
Power supply conditions: three-phase four wire+protective ground wire, voltage range: AC (380 ± 38) V;
Allowable frequency fluctuation range: (50 ± 0.5) Hz;
The grounding resistance of the protective grounding wire is less than 4 Ω;
Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must be used independently for the equipment;
Water supply conditions: Purified water is required for equipment humidification.
637218668896286675685.jpg