Spray cooling outside the air conditioner
How to rectify high temperature overload of air conditioning outdoor unit? In the hot summer, air conditioning has become a good helper for cooling people's lives. Air conditioning consists of an indoor unit and an outdoor unit. Outdoor units are generally concentrated on rooftops or hardened floors. When the outdoor temperature exceeds 35 degrees, the temperature of the concrete on the rooftop is even higher, causing the temperature around the outdoor unit to be too high, resulting in a decrease in cooling effect or failure to cool. This not only leads to a decrease in cooling effect but also increases air conditioning energy consumption.
Our company has developed ultra-fine mist equipment for application in the field of cooling based on spraying. This equipment uses ultra-fine mist to form mist clusters around the outdoor unit of the air conditioner, with a double-layer cooling effect. Firstly, the high-temperature air evaporates some of the water mist, causing the temperature of the surrounding air to decrease. The water mist that has not been evaporated will be sucked into the evaporator of the air conditioner unit. Due to the high surface temperature of the evaporator, the water mist enters the evaporator and adsorbs on its surface for secondary cooling. Since the ultra-fine water mist does not condense scale on the surface of the evaporator. You can use it with confidence.
Spray cooling outside the air conditioner——Principle:
The spray cooling equipment of the external unit of the humidification air conditioner uses the company's core water treatment technology to pressurize the tap water through (0.002 micron physical technology treatment) with a motor driven high-pressure pump, spray out through a special pipe and nozzle, and instantly absorb the heat in the air after mixing with the air, so that it can be distributed to achieve the spray cooling effect. Control the operation and stop of the motor through an electrical control system. Mist droplets with a diameter of micrometers are generated from the nozzle, which disperse in the air and evaporate, taking away the surrounding heat,Quickly cool down the surrounding air,Thus achieving the effect of cooling.
Fine fog: 3~20um fog particles, especially clouds in the mountains, can be directly absorbed by the air quickly, cooling the surrounding air, and the spray cooling effect is superior.
Energy saving: The electricity consumption is very low: the direct electricity consumption for atomizing 1kg of water per hour is only 3-6W, which also includes the electricity consumption of the external water filtration system. Further proof has been providedSpray cooling outside the air conditionerThe device is an energy-saving product;
Continuous adjustability: It can achieve continuous control of time on and off.
Easy to maintain: Simply replace the lubricating oil of the high-pressure plunger pump regularly.
Reliability: Three asynchronous motors are used as the power source in conjunction with an industrial plunger pump, which can operate continuously for 24 hours. The nozzle and fittings have no power sensitive components and will not be damaged even in poor environmental conditions;
Compliant with high hygiene standards: water sealed and non reusable, will not cause bacterial growth;
Spray cooling of external air conditioning unit——configuration table
Serial Number |
System name |
Name of each unit |
Brand (optional) |
origin |
1 |
High pressure pump station
|
High pressure ceramic plunger pump |
BT |
Italy |
Industrial motors |
ABB |
Switzerland |
||
High pressure drain solenoid valve |
AGY-5 |
Italy |
||
High pressure inlet solenoid valve |
AGY-20 |
Italy |
||
control system |
Ong wet |
Ong wet |
||
Pressure sensor |
TRGFAG |
Switzerland |
||
2 |
Host shell |
stainless steel |
Ong wet |
Ong wet |
3 |
Mist spray nozzle |
AS-20-145 |
Water mist |
Taiwan |
4 |
Pipeline and accessories |
AS-10 |
Shanghai |
Shanghai |
6 |
water treatment |
China |
China |
China |
Spray cooling of external air conditioning unit——Technical Parameter
model |
ASGY-12 |
ASGY-15 |
ASGY-19 |
ASGY-25 |
ASGY-30 |
ASGY-40 |
ASGY-50 |
voltage |
380/50hz |
380/50hz |
380/50hz |
380/50hz |
380/50hz |
380/50hz |
380/50hz |
power |
2.2kw |
3kw |
4kw |
4kw |
5kw |
5kw |
7kw |
Scope of use |
Load capacity area of a single host100~15000square meter |
||||||
control mode |
automatic control |
||||||
|
Note: The specific number of nozzles depends on the sealing effect, air exchange rate, workshop height, indoor temperature, humidity requirements, and other factors in the workshop Multi channel control can also be configured | |||||||