QDL2-20 stainless steel multi-stage pump is also suitable for slightly alkaline water, mineral water, distilled water, swimming pool water, and other chloride containing liquids, but the allowable temperature of the liquid needs to be lowered.
Product Details

1、 Working conditions of QDLF2-20 stainless steel multi-stage pump
1. Cold and hot clean, non flammable and non explosive liquids that do not contain solid particles or fibers;
2. Liquid temperature: -15 ℃ to+120 ℃
3. Environmental temperature: High+40 ℃
4. Small inlet pressure: Based on the NPSH curve and a small safety head of 0.5 meters.

II
QDL2-20 stainless steel multi-stage pump
Scope of application
QDL stainless steel multi-stage pump
The regular type is suitable for liquid transmission, circulation and pressurization of hot and cold cleaning water and softened water.
QDLF stainless steel multi-stage pump
It is also applicable to slightly alkaline water, mineral water, distilled water, swimming pool water, and other chloride containing liquids, but the allowable temperature of the liquid needs to be lowered.

III
QDLF vertical multi-stage pump
Typical Applications
1.
Applied to municipal water supply and boosting
2.
Applied to industrial circulation systems and processing systems
3.
multistage pump
Applied to boiler feedwater and condensate systems
4.
QDL2-20 stainless steel multi-stage pump
Applied to household water supply
5.
QDL pump
Applied to environmental water treatment, infiltration analysis system
6.
Used for agricultural irrigation and dehydration
7.
vertical pump
Applied to industrial plant cleaning and various cleaning tasks
8.
Used for (other) many specialized purposes

Stainless steel multi-stage pumpPerformance Parameter Table
QDL2/QDLF2 Performance Parameter Table
model
Equipped with motor
(kW)
Q
m3/h
1
1.2
1.6
2
2.4
2.8
3.2
3.5
QDL2-20
0.37
H (m)
18
17
16
15
13
12
10
8
QDL2-30
0.37
27
26
24
22
20
18
15
12
QDL2-40
0.55
36
35
33
30
26
24
20
16
QDL2-50
0.55
45
43
40
37
33
30
24
20
QDL2-60
0.75
53
52
50
45
40
36
30
24
QDL2-70
0.75
63
61
57
52
47
41
35
28
QDL2-90
1.1
80
78
73
67
61
54
45
37
QDL2-110
1.1
98
95
89
82
73
64
54
44
QDL2-130
1.5
116
114
106
98
89
78
65
52
QDL2-150
1.5
134
130
123
112
10
90
73
60
QDL2-180
2.2
161
157
148
136
121
108
91
76
QDL2-220
2.2
197
192
180
165
148
130
110
90
QDL2-260
3
232
228
214
198
179
158
130
110
QDL4/QDLF4 Performance Parameter Table
model
Equipped with motor
(kW)
Q
m3/h
1.5
2.0
3.0
4.0
5.0
6.0
7.0
8.0
QDL4-20
0.37
H (m)
19
18
17
15
13
10
8
6
QDL4-30
0.55
28
27
26
24
20
18
13
10
QDL4-40
0.75
38
36
34
32
27
24
19
13
QDL4-50
1.1
47
45
43
40
34
31
23
17
QDL4-60
1.1
56
54
52
48
41
37
28
20
QDL4-80/7
1.5
66
63
61
56
48
43
33
24
QDL4-80
1.5
74
72
70
64
55
50
38
27
QDL4-100
2.2
96
90
87
81
71
62
48
34
QDL4-120
2.2
114
108
104
95
85
75
58
41
QDL4-160/14
3.0
136
126
122
112
101
89
68
48
QDL4-160
3.0
152
144
140
129
115
101
78
55
QDL4-190
4.0
183
171
168
153
137
122
93
67
QDL4-220
4.0
211
200
192
178
160
138
108
79
QDL8/QDLF8 Performance Parameter Table
model
Equipped with motor
(kW)
Q
m3/h
5
6
7
8
9
10
11
12
QDL8-20
0.75
H (m)
21
20
19
18
17
16
15
14
QDL8-30
1.1
31
30
29
28
26
24
23
20
QDL8-40
1.5
41
40
39
37
35
32
30
27
QDL8-50
2.2
52
50
48
46
44
41
37
34
QDL8-60
2.2
62
60
58
55
53
49
45
41
QDL8-80
3.0
83
80
78
74
70
65
60
54
QDL8-100
4.0
104
100
97
92
88
80
75
68
QDL8-120
4.0
125
120
116
110
105
97
90
81
QDL8-140
5.5
146
140
136
129
123
113
105
95
QDL8-160
5.5
166
160
155
147
140
130
120
108
QDL8-180
7.5
187
180
175
166
158
146
135
122
QDL8-200
7.5
208
200
194
185
175
162
150
135
QDL16/QDLF16 Performance Parameter Table
model
Equipped with motor
(kW)
Q
m3/h
8
10
12
14
16
18
20
22
QDL16-30/2
2.2
H (m)
28
27
26
25
23
21
19
17
QDL16-30
3.0
42
41
39
37
35
32
29
26
QDL16-40
4.0
56
54
52
50
47
44
38
34
QDL16-50
5.5
69
68
65
62
59
54
48
43
QDL16-60
5.5
83
81
78
75
70
64
58
52
QDL16-70
7.5
97
95
92
87
82
75
68
61
QDL16-80
7.5
111
108
105
100
94
86
77
70
QDL16-100
11
139
136
131
125
118
108
97
87
QDL16-120
11
167
163
157
150
141
129
116
105
QDL16-140
15
194
190
184
175
165
151
136
122
QDL16-160
15
222
217
210
200
189
173
155
140

Stainless steel multi-stage centrifugal pumprepairInstructions

Before the pump starts working, it should be confirmed that there is no power supply to the pump and the pump cannot suddenly start. The bearings and shaft seals of the pump do not require maintenance. If the pump is not in use for a long time and needs to be drained, one of the coupling guard plates can be removed, and a few drops of silicone oil can be injected into the shaft between the pump head and the coupling. This can prevent the shaft sealing surface from sticking. When installing the coupling guard, be sure that they are vertically aligned in the recess of the pump head. Before the pump starts working, it should be confirmed that there is no power supply to the pump and the pump cannot suddenly start. The bearings and shaft seals of the pump do not require maintenance. If the pump is not in use for a long time and needs to be drained, one of the coupling guard plates can be removed, and a few drops of silicone oil can be injected into the shaft between the pump head and the coupling. This can prevent the shaft sealing surface from sticking. When installing the coupling guard, be sure that they are vertically aligned in the recess of the pump head.Electric motor bearings:Electric motors without lubrication nozzles do not require maintenance. Electric motors equipped with lubrication nozzles should be lubricated with high-temperature lithium based grease. If the electric motor is used seasonally (for motors that are not used for more than six months a year), it is recommended to clean and lubricate the pump and motor once they are not in use.Frost protectionDuring frost, if the pump is not in use, the water should be drained to prevent damage and cracking. Loosen the exhaust screw on the pump head and remove the drain plug on the base to drain the pump. After the water is drained, the removed components should be reinstalled or properly stored. Pay attention that the discharged liquid will not cause harm to people, or damage to the motor or other components. In hot water systems, special attention should be paid to the risk of burns caused by hot water. Do not tighten the exhaust screw and resend the drain plug until the pump is reused. Before placing the drain plug back on the base, the bypass valve should be rotated out towards the stopper, as shown in Figure 7. Install the drain plug by tightening the large connecting nut under the bypass valve. The reinstallation program is still a reverse program operation for disassembly.

Troubleshooting of vertical multi-stage centrifugal pump

Fault reason
1. The electric motor starts but does not rotate. a) Power outage. b) The fuse is burnt out. c) The starter overload has been disconnected. d) The main contacts inside the starter are not in contact or there is a problem with the coil. e) The fuse in the control circuit is defective. f) There is a problem with the electric motor.
2. As soon as the power is turned on and the starter is overloaded, it will immediately trip off. a) The fuse is burnt out. b) There is an issue with the overload contact of the starter. c) The cable connection is loose or faulty. d) The electric motor unit has defects. e) The pump is mechanically blocked. f) The overload setting is too low.
3. The starter occasionally trips due to overload. a) The overload setting is too low. b) Low voltage during peak hours.
4. The protector has never tripped, but the pump is not running. a) Check 1 a), b), c), and e)
5. The flow rate of the pump is unstable. a) The inlet pressure of the pump is too low. b) The suction pipe/pump is partially blocked by impurities. c) The pump has drawn in air.
6. The pump is running but not producing water. a) The suction pipe/pump is blocked by impurities. b) The base or check valve is blocked in the closed position. c) Leakage of suction pipe. d) There is air inside the suction pipe or pump. e) The direction of rotation of the electric motor is incorrect.
7. Reverse when the pump is turned off. a) The suction pipe is leaking. b) The base or check valve is faulty. c) The base valve is blocked in the open or partially open position. d) The check valve is leaking or blocked in some open positions.
8. Leakage of shaft seal. a) The position of the pump shaft is incorrect. b) The shaft seal is faulty.
9. Noise. a) There is an air phenomenon inside the pump. b) Due to the incorrect position of the inner shaft of pump 1, the pump cannot rotate freely (due to frictional resistance). c) There is resonance at the installation location.

Stainless steel multi-stage pumpOrdering Notice:
1、 ① Product name and
pumpModel ②pumpCaliber ③ stainless steel multi-stage pumpHead (m) ④ Corrosion resistant multi-stage pumpTraffic ⑤Motor power (KW) ⑥Vertical lightweight multi-stage pumpSpeed (r/min) ⑦Voltage [V] ⑧ Stainless steel multi-stage pumppumpMaterial ⑨Vertical lightweight multi-stage pump
Do you have any attachments so that we can make the correct selection for you.
2、 If our company has already been selected by the design unit
Product model, please pressmultistage pump
Order the model directly from the company's sales department.
3、 When the usage situation is very important or the environment is complex, please provide design drawings and detailed parameters as much as possible, and our technical experts from Zhongqiu Pump Industry will review and control them for you.
Thank you for visiting us at Zhongqiu Pump Industry
If you have any questions You can call us, and we at Zhongqiu Pump Industry will do our best to provide you with high-quality service.