-
Phone
1572319679715922634908
-
Address
Chongqing Jiulongpo High tech Industrial Development Zone
Chongqing Panheng Valve Co., Ltd
1572319679715922634908
Chongqing Jiulongpo High tech Industrial Development Zone
1、 Scope of use
Pilot piston stainless steel solenoid valve is an actuator used in industrial process automation control systems. It can automatically open or close upon receiving electrical control signals, achieving control over the on/off or flow regulation of liquid media in pipelines. Stainless steel solenoid valves are mainly used for controlling liquid media such as corrosive liquids, ultra clean liquids, and edible liquids.
2、 Technical parameters
principle structurePilot piston stainless steel solenoid valve
Coil operating temperature<+50 ℃,<+85 ℃
Control method: Normally open (turned off when powered on, turned on when powered off); Normally closed (power off to close, power on to open)
Nominal Diameter:DN0.5-DN500mm
standard voltage:AC220V、DC24V、DC12V
Media typeVarious types of water, gas, oil, corrosive media, etc.
Temperature of circulating fluid<-40 ℃,<+60 ℃,<+80 ℃,<+380 ℃
Circulating fluid pressure:-0.1-100MPa
Valve body materialStainless steel (304, 316), cast iron (HT200)
Coil connection methodExplosion proof cover, three core sheathed cable, lead type, plug type
Sealing material performance: Temperature resistance, pressure resistance, wear resistance, corrosion resistance
connection method: Flanges, threads, welding
sealed structureSealing between flat and conical surfaces
Leakage rate: Zero leakage
Closing TimeWithin 1 second
Performance CharacteristicsHigh sensitivity, strong sealing, high safety, long lifespan, and high cost-effectiveness
scope of workAerospace, defense military products, nuclear industry, shipbuilding industry, petrochemicals, power equipment, pharmaceutical equipment, industrial furnaces, drying equipment, fire-fighting equipment, stage effects, HVAC, cleaning equipment, electroplating and coating, filling and metering, machine manufacturing, food industry, water treatment system ultra-high voltage control system, etc.
annotation:
1. Before installing the solenoid valve, impurities and welding slag in the pipeline must be cleaned to avoid leakage inside the valve body.
2. The solenoid valve can only be installed horizontally under normal working conditions, and it needs to be explained in advance when installed vertically.
3. After the installation of the solenoid valve is completed, it should be operated several times before it can be put into use.
Ordering Instructions
1. Please specify the model, nominal diameter, nominal pressure, working medium, working pressure difference, medium temperature, power supply voltage and power, and medium viscosity when placing an order.
2. If the opening time of the valve exceeds 12 hours/day, please choose a normally open solenoid valve. When used in explosive environments, please choose explosion-proof solenoid valves.
3. If you have any questions, please call us for consultation! Our company staff will do their best to solve your problem and provide you with the most perfect solution!