TANWELL sensorSK081T-070-50,SK205-050-H020,SK081T-110-500, The change in fluid flow rate is reflected by measuring the difference in resistance between these two thermistors. Wear resistant thermal flow sensors can be used for monitoring the flow rate of liquid or gas media. High cost-effectiveness. The displacement monitor is a four channel monitor. It can accept non-contact sensor outputs, enabling it to calculate more than 14 key parameters for each channel. The module includes a built-in relay (expandable to five) and two 4-20mA outputs.
TANWELL sensorSK081T-070-50,SK205-050-H020,SK081T-110-500, The change in fluid flow rate is reflected by measuring the difference in resistance between these two thermistors. Wear resistant thermal flow sensors can be used for monitoring the flow rate of liquid or gas media. High cost-effectiveness. The displacement monitor is a four channel monitor. It can accept non-contact sensor outputs, enabling it to calculate more than 14 key parameters for each channel. The module includes a built-in relay (expandable to five) and two 4-20mA outputs.
代理 turck,AFM,hydrotechnik,bently,ai-tek,entek,mtl
The BENTLY 330750 design in the United States separates the speed probe from the signal processing circuit and connects it with a sturdy cable, allowing the speed probe to have a much wider temperature range than our other Velomitor sensors.
BENTLY 190501 from the United States is our low-frequency Velomitor sensor used for monitoring cooling towers with rotation speeds as low as 90 rpm
Functional principle
Plug in flow sensors are based on the thermal principle. The measuring probe heats up by comparing with the temperature of the fluid medium, and when the fluid passes through the probe, it takes away some of the heat. The change in fluid flow rate is reflected by measuring the difference in resistance between these two thermistors. Turck wear-resistant thermal flow sensors can be used for flow rate monitoring of liquid or gas media.
Traffic alarm monitoring,
Used for matching flow sensors
IO link parameter setting, relay output
■Can be used for monitoring overspeed and underspeed values
■Linear monitoring
■Work range 0.06... 600000 mins-1
■Can connect 3 wires and comply with EN 60947-5-6 standard
NAMUR sensor, externally powered
■2 relay outputs and 1 transistor output
■Output current (0/4... 20 mA)
■pulse output
■Set parameters using FDT/DTM software via PC
Set, through the front panel or HART ®
■Intrinsic safety output circuit
Switch status indication
6 LED indicator light chains green/yellow/red
The light indicates the flow rate status
6 LED indicator light chains
Display: Flow rate below set value
LED indicator light red
Display: Flow rate is equal to the set value
LED indicator light yellow
Display: Flow rate higher than the set value
4-channel LED indicator light green
Installation method
Plug in sensor
scope of work
1…150cm/s
scope of work
3…300cm/s
Switch characteristics
typ. 8 s (2…15 s)
open time
typ. 2 s (1…15 s)
Close time
typ. 2 s (1…15 s)
Temperature gradient, response time
Big 12 seconds
temperature gradient
ð 250 K/min
medium temperature
-20…80 °C
Working Voltage
195…264VAC
Current loss
ð 30 mA
output performance
Relay output, complementary contacts
Rated working current
4 A
short circuit protection
No
AC switch voltage
250 VAC
DC switch voltage
60 VDC
Large AC switch capacity