1、 Description:
This instrument adopts the transient plane heat source method and tests materials based on the transient plane heat source technology:Thermal conductivity coefficient, thermal conductivity coefficient (thermal diffusion coefficient) and specific heat capacity, thermal storage coefficient and thermal resistance of solid, powder, liquid, paste, coating, film, thermal insulation material, thermal insulation material, anisotropic material, such as metal, alloy, graphite, thermal conductive silicone grease, silica gel, silicone rubber, ceramics, rock, polymer, paper, fabric, foamed plastic, concrete, composite plate, paper honeycomb plate, etc.
2、 Execution standards
Standard:ISO 22007-2:2008, GB/T32064-2015
Three,Technical Specifications:
Control system:PLC+WindowsSystem;
Operating interface: Color12Inch embedded industrial computer,WiFiconnect;
Wireless printing function,Using fully automated testing software to quickly and accurately analyze the parameters of the sample during the testing process and output reports;
Measurement range of thermal conductivity:0.001~500 w/(m.k),The resolution is0.0001w/(m.k);
Range of thermal diffusivity (thermal conductivity):0.1~100 m2/s;
Range of heat storage coefficient:0.1~30 w/(m2.k);
Specific heat capacity range:0.1~5 kJ/(kg.℃);
Thermal resistance range:0.5~0.000005 mm2.k/w;
Temperature measurement accuracy: ≤0.001℃;
Relative measurement error: ≤3%;
Repetitive error: ≤3%;
Test time:1~120 In seconds.
Temperature range of sample testing environment:optional-40~150℃; Standard configuration: Room temperature.
Probe configuration: Standard configuration: Diameter Φ15mm.
Optional probe diameter: Φ30mm,Φ15mm,Φ7.5mm;
power supplyAC 220V±10%,50/60 Hz;
Whole machine power: <500w;
Standard external dimensions:L761* W500* H786mm;
Optional external dimensions: Long921wide600high856.5mm
3、 Probe technical specifications:
1. Heating material: nickel metal;
2. Operating temperature-50~150℃;
3. Power:20w;
4. Voltage:20V;
5. electric current:1A;
6. Resistance:10Approximately Ω, according to the resistance value marked on the probe;
7. Nickel wire specification: thickness0.01mm,Hot wire width:0.35±0.03mm;
Hot wire spacing:0.35±0.03mm;
8. Protective layer material: polyimide film; Single layer thickness:0.06mm;
9. Probe diameter: Φ30mm,Φ15mm,Φ7.5mm.
10.Total thickness of probe (including adhesive layer thickness)0.07±0.02mm.