Product Introduction: The tubular electrostatic precipitator uses a high-voltage electric field to ionize the flue gas, and the charged dust in the airflow is separated from the airflow under the action of the electric field. The negative electrode is made of metal wires with different cross-sectional shapes and is called a discharge electrode. The positive electrode is made of metal plates with different geometric shapes, called a dust collecting electrode. Its performance is affected by the nature of dust and equipment structure .....

Product Details

The tubular electrostatic precipitator uses a high-voltage electric field to ionize the flue gas, and the charged dust in the airflow is separated from the airflow under the action of the electric field. The negative electrode is made of metal wires with different cross-sectional shapes and is called a discharge electrode. The positive electrode is made of metal plates with different geometric shapes, called a dust collecting electrode. Its performance is affected by three factors: dust properties, equipment structure, and flue gas flow rate. The specific resistance of dust is an indicator for evaluating conductivity, which has a direct impact on dust removal efficiency. The specific resistance is too low, making it difficult for dust particles to remain on the dust collection electrode, resulting in their return to the airflow. If the specific resistance is too high, the dust particles that reach the dust collection electrode are not easily discharged, and a voltage gradient is formed between the dust layers, which can cause local breakdown and discharge phenomena.



Single tube Double tube Three pipes Four pipes
Diameter MM Φ800 Φ900 Φ800 Φ900 Φ800 Φ900 Φ800 Φ900
Heteropolar distance MM 400 450 400 450 400 450 400 450
filter area M2 0.5 0.64 0.1 1.28 1.5 1.9 2.0 2.54
filtration velocity M/S 1 1 1 1 1 1 1 1
Processing air volume M3/h 1800 2300 3600 4600 5400 6800 7200 9200
corona wire shape Garden Line Star Line Thorn Line
Corona discharge voltage 80KV-120KV
Clearing ashes method Electromagnetic vibration or electric vibrator vibration
Smoke and gas temperature Room temperature 350 ℃
specific resistance ΩCm 104/1012
Electric field length M 8-10
Equipment weight T 3.7 4.2 8.5 6.3 6.8 7.3 8.8 9.2


Six pipes Eight pipes Ten pipes
Diameter MM Φ800 Φ900 Φ800 Φ900 Φ800 Φ900
Heteropolar distance MM 400 450 400 450 400 450
filter area M2 3.0 3.84 4.0 5.12 5.0 6.4
filtration velocity M/S 1 1 1 1 1 1
Processing air volume M3/h 10800 13800 14400 18400 18000 23000
corona wire shape Garden Line Star Line Thorn Line
Corona discharge voltage 80KV-120KV
Clearing ashes method Electromagnetic vibration or electric vibrator vibration
Smoke and gas temperature Room temperature 350 ℃
specific resistance Ω Cm 104/1012
Electric field length M 8-10
Equipment weight T 10.8 10.8 19 21 22 23