E-mail
tao.xu.rl@pgeneral.com.cn
-
Phone
18001075583
-
Address
No. 3 Pingsan Road, Pinggu District, Beijing
Beijing Puxi General Instrument Co., Ltd
tao.xu.rl@pgeneral.com.cn
18001075583
No. 3 Pingsan Road, Pinggu District, Beijing
Universal atomic fluorescence spectrophotometer--PF3 series atomic fluorescence spectrophotometer
The PF3 series atomic fluorescence spectrophotometer has a commonly used injection pump sequential flow injection system, which supports single point calibration, automatic dilution, and other operations. It also has a universal analyzer dual beam, dimming lamp, etcpracticalTechnology, fast testing, reliable quality, high degree of automation, is universal fluorescence analysisseriesin the productrepresentative productone of
The syringe uses pure water medium to solve the problem of damage to measuring instruments caused by acid and alkali solutions.
√ No debugging required
1Plug and play element lightpracticalTechnology, no manual adjustment required for lamp replacement, lamp positionGood consistencyThe test results are more reliable.
2Quartz furnace atomizerofAuto SetuptoWork area, no visual adjustment required, convenientfast.
√ More stable
1. DoubleThe practical technology of beam single detector reduces the influence of light source fluctuations during the testing process and improves the detection accuracy.
2. Gas displacement automatic liquid replenishment sampling needle cleaning technology, achieving simultaneous cleaning of the inner and outer walls of the sampling needle to avoid cross contamination of high and low concentration samples.
3. Reflux gas-liquid separator,The gas-liquid separation effect is good, and only one stage of gas-liquid separation can achieve the removal of water vapor and bubbles.
√ More environmentally friendly
1. Adopting the exhaust gas closed diversion technology, the exhaust gas is discharged outdoors after adsorption treatment through the diversion channel, ensuring the safety and environmental protection of the analysis work.
2. Sealed storage of waste liquid reduces volatilization, has overflow alarm, and is safer to use.
√ More applicable
1. Can quickly connect morphological analysis units to form an atomic fluorescence morphological analyzer;
2. Can be connected to high injection volume trace element testing accessories to meet the testing needs of users for ultrafine content samples;
3. Can connect micro injection attachments with small injection volumes to meet the needs of users for small injection volumes of samples.
Instrument configuration:
Flow path: Fully automatic sequential injection injection flow path system
Optical path: Dual beam single detector optical system
Universal atomic fluorescence spectrophotometer--PF5 series atomic fluorescence spectrophotometer
The PF5 series atomic fluorescence spectrophotometer is divided into single channel, dual channel, multi-channel and other models. The product adopts gas source sequential flow injection, adjustable lamp, roll flow gas-liquid separator, dual beam, etcpracticalTechnology has improved atomic fluorescence manufacturing techniques such as quartz atomizers and non dispersive short focal length optical paths.
√ Maintenance free
1. Pneumatic flow system without wear and tear parts, eliminating the maintenance troubles of peristaltic pumps.
2. The syringe uses pure water medium to solve the problem of damage to measuring instruments caused by acid and alkali solutions.
√ No debugging required
1. Plug and play element lamp technology, no manual adjustment required for lamp replacement, lamp positionGood consistencyThe test results are more reliable.
2. Quartz furnace atomizerofAuto SetuptoWork area, no visual adjustment required, convenientfast.
√ More stable.
1. Dual beam single detector optical system, effectively deducing excitation light source drift and fluctuations, mercury testing stabilityOkay.
2. Pneumatic flow system, constant pressure and constant flow with small sample deviation, allowing for long-term testing of the same sampleThe difference is small.
3. Can achieve online, reverse, and multiple cleaning, with minimal sample residue and high testing capabilityconcentration.
4. Vapor-liquid separator, cooling water removal, stirring and mixing,Can increase the magnitude of improvementSensitivity.
√ More environmentally friendly
1. Adopting the exhaust gas closed diversion technology, the exhaust gas is discharged outdoors after adsorption treatment through the diversion channel, ensuring the safety and environmental protection of the analysis work.
2. Sealed storage of waste liquid reduces volatilization, has overflow alarm, and is safer to use.
√ More applicable
1. Can quickly connect morphological analysis units to form an atomic fluorescence morphological analyzer.
2. Can be connected to high injection volume trace element testing accessories to meet the testing needs of users for ultrafine content samples.
3. Can connect micro injection attachments with small injection volumes to meet the needs of users for small injection volumes of samples.
Instrument configuration:
Flow path: Fully automatic pneumatic sequential injection injection flow path system
Optical path: Dual beam single detector optical system
Universal atomic fluorescence spectrophotometer--PF7 series atomic fluorescence spectrophotometer
The PF7 series atomic fluorescence products are independently developed atomic fluorescence spectrophotometer products by Puxi Company.
The PF73 atomic fluorescence spectrophotometer won the gold medal in the "Food Testing Instrument Performance Competition" in August 2014.
The product adopts gas source sequential flow injection technology, dual beam optical structure, and information-based sample management system, which solves the problem of poor durability of peristaltic pumps, improves the problem of poor stability of super-resolution analysis instruments, and realizes the construction mode of atomic fluorescence product technology without peristaltic pump maintenance and dual beam calibration.
√ Maintenance free
1. Pneumatic flow system without wear and tear parts, eliminating the maintenance troubles of peristaltic pumps.
2. The syringe uses pure water medium to solve the problem of damage to measuring instruments caused by acid and alkali solutions.
√ Non adjustable
1. Plug and play element lamp technology, no manual adjustment required for lamp replacement, lamp positionGood consistency, checkReliable test results.
2. Quartz furnace atomizerheightAuto SetuptoWork area, no visual adjustment required, convenientfast.
√ More stable
1. Dual beam single detector optical system, effectively deducing excitation light source drift and fluctuations, mercury testing stabilityOkay.
2. Pneumatic flow system, constant pressure and constant flow with small sample deviation, allowing for long-term testing of the same sampleThe difference is small.
3. Can achieve online, reverse, and multiple cleaning, with minimal sample residue and high testing capabilityconcentration.
4. Vapor-liquid separator, cooling water removal, stirring and mixing,enhanceSensitivity.
√ More environmentally friendly
1. Adopting the exhaust gas closed diversion technology, the exhaust gas is discharged outdoors after adsorption treatment through the diversion channel, ensuring the safety and environmental protection of the analysis work.
2. Sealed storage of waste liquid reduces volatilization, has overflow alarm, and is safer to use.
√ More applicable
1. Can quickly connect morphological analysis units to form an atomic fluorescence morphological analyzer.
2. Can be connected to high injection volume trace element testing accessories to meet the testing needs of users for ultrafine content samples.
3. Can connect micro injection attachments with small injection volumes to meet the needs of users for small injection volumes of samples.
Instrument configuration:
Flow path: Fully automatic pneumatic sequential injection injection flow path system
Optical path: Dual beam single detector optical system
Other: Optional fingerprint login management system
Optional barcode recognition sample management system