Welcome Customer !

Membership

Help

Shanghai Dinghuan Fluid Control Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Shanghai Dinghuan Fluid Control Co., Ltd

  • E-mail

    2282564066@qq.com

  • Phone

    15900434156

  • Address

    A2-2 Floor, No. 688 Huancheng North Road, Fengxian District, Shanghai (Weilong Science and Technology Innovation Industrial Park)

Contact Now

VYRON electromagnetic diaphragm metering pump automatic dosing pump VKS series

NegotiableUpdate on 04/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The VYRON electromagnetic diaphragm metering pump automatic dosing pump VKS series is a digital electromagnetic driven dosing metering pump based on microprocessor control. The following is its related introduction: The working principle of $r $n is to use an electromagnetic push rod to drive the diaphragm to reciprocate inside the pump head, causing changes in the volume and pressure of the pump head chamber, thereby opening and closing the suction valve and discharge valve, achieving quantitative suction and discharge of liquid.
Product Details

VYRON electromagnetic diaphragm metering pump automatic dosing pump VKS series is introduced in detail below4

  • working principleBased on microprocessor control, using electromagnetic drive, the diaphragm is driven back and forth in the pump head by an electromagnetic push rod, changing the volume and pressure of the pump head chamber, opening and closing the suction valve and discharge valve, and achieving quantitative suction and discharge of liquid.

  • Technical Specifications

    • flow range:0.4 - 110L/H。

    • maximum pressure:20bar。

    • Stroke flow rate0.06-6.11 milliliters per stroke.

    • maximum power:40W。

  • Product Features

    • stable operationElectromagnetic drive has a simple structure, stable operation, and easy maintenance. The diaphragm is made of pure solid PTFE material, with a long service life and compatibility with most chemicals.

    • Good chemical compatibilityPVDF pump head and ceramic ball valve are standard configurations, and PVDF pump head is almost compatible with all chemicals used in industrial, sewage treatment, and drinking water fields. Ceramic ball valve improves the reliability of drug delivery and the chemical compatibility of the entire liquid contact end.

    • Diverse modes of medication administrationThe flow rate can be adjusted manually or automatically (signal input control).

  • Application fieldMainly used in municipal water treatment and wastewater treatment, chlorine dioxide dosing, reverse osmosis, food, beverage, and pharmaceutical industries, and can also be used for dosing in swimming pools below 500 cubic meters.





  1. preparation

    • security checkEnsure the safety of the work area, check the connection of the power supply, related equipment, and the integrity of the metering pump. If there are any abnormalities or damages, promptly handle or replace them.

    • Select installation locationChoose a suitable location for installing the metering pump, taking into account the convenience of operation, pipeline connection, and maintenance needs. Choose a stable and away from chemicals or other hazardous substances.

    • Determine pipeline connection pointsAccording to the application requirements and the inlet and outlet requirements of the metering pump, determine the connection position with the pipeline to ensure that the inlet and outlet pipelines can be easily connected during the installation process.

    • Prepare brackets and connectorsBased on the size and weight of the metering pump, select appropriate installation brackets and connectors, such as bolts, support frames, pipe joints, valves, etc., to ensure that they have sufficient strength and stability.

  2. mounting bracketAccording to the design and specifications of the bracket, use bolts or other fixing devices to fix the bracket to the ground or wall. It is necessary to ensure that the bracket is installed firmly and can withstand the weight of the metering pump and the vibration generated during operation.

  3. Install pump bodyPlace the metering pump on the installation bracket, align it according to the design of the pump and bracket, and then use bolts or other fixing devices to fix the pump body on the bracket, ensuring that the pump body is installed firmly and will not loosen or shift.

  4. connecting pipe

    • Inlet connectionConnect the inlet of the pump to a liquid container or supply system, use a transparent and flexible suction pipe, and install a bottom valve and filter. If the liquid container is lower than the pump, an anti backflow valve or air release valve needs to be installed on the suction pipe to prevent siphon phenomenon.

    • Liquid outlet connectionConnect the outlet of the pump to the injection point or infusion system, use a white hard output tube, and install an injector and exhaust valve. If the injection point is higher than the pump, an anti back pressure valve or air release valve needs to be installed on the output pipe to prevent bending. Ensure that the pipeline connections are tight and take appropriate sealing measures to prevent leaks, while paying attention to the direction and bending of the pipeline to avoid excessive stretching or twisting.

  5. Install attachments and accessoriesInstall accessories and fittings according to actual needs, such as flow meters, pressure sensors, etc. Follow the installation guidelines for accessories and fittings to ensure that they are correctly connected to the metering pump.

  6. electrical connection

    • Connect to powerConnect the power cord of the pump to a power socket that meets its voltage and frequency requirements, and protect it with an air switch or fuse.

    • Grounding treatmentEnsure that the pump has a good grounding connection to prevent electric shock or interference.

    • functional connectivityIf remote control or signal input/output functions are required, the control interface of the pump can be connected to the corresponding equipment or system, such as pulse signals, analog signals, 485 signals, etc., and set and adjust according to the instructions.

  7. Adjustment and calibrationAccording to the provided operation manual and guidance, adjust the settings and parameters of the metering pump, such as speed, stroke length, and other related parameters, to achieve the required liquid flow rate and metering accuracy. During the adjustment and calibration process, pay attention to observing the operation of the metering pump. If there are any abnormalities, stop and check in a timely manner.

  8. Trial operation inspectionAfter installation, conduct a trial run of the pump to check for any abnormal conditions such as leakage, blockage, noise, vibration, etc


VYRON electromagnetic diaphragm metering pump automatic dosing pump VKS series