Welcome Customer !

Membership

Help

Shanghai Dinghuan Fluid Control Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Shanghai Dinghuan Fluid Control Co., Ltd

  • E-mail

    2282564066@qq.com

  • Phone

    15900434156

  • Address

    A2-2 Floor, No. 688 Huancheng North Road, Fengxian District, Shanghai (Weilong Science and Technology Innovation Industrial Park)

Contact Now

VYRON mechanical diaphragm metering pump automatic dosing pump GW series

NegotiableUpdate on 04/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The following is an introduction to the VYRON mechanical diaphragm metering pump automatic dosing pump GW series: $r $n Product features $r $n #183; Structurally, there is no leakage. #183; PVC, PTFE, 304, 316L and other materials can be used as pump head materials. Suitable for various acid and alkali resistant medicinal solutions. Can be installed on the medicine barrel. $r$n #183; Easy installation, easy maintenance and upkeep. The $r $n operation has high security performance. During the operation of $r $n, the flow rate can be adjusted arbitrarily.
Product Details

VYRON mechanical diaphragm metering pump automatic dosing pump GW series is introduced in detail below4

  • Product Features

  • ·Structurally, there is no leakage. ·PVC, PTFE, 304, 316L and other materials can be used as pump head materials. Suitable for various acid and alkali resistant medicinal solutions. Can be installed on the medicine barrel.

  • ·Easy installation, easy maintenance and upkeep.

  • High operational safety performance.

  • Adjust the flow rate arbitrarily during operation.

  • Technical Specifications

    • flow range:30 - 150L/H。

    • maximum pressure:5bar。

    • power range:60W、90W

  • Application fieldMainly used in municipal water treatment and wastewater treatment, chlorine dioxide dosing, reverse osmosis, food, beverage, and pharmaceutical industries, and can also be used for dosing in swimming pools below 500 cubic meters.





  1. preparation

    • security checkEnsure the safety of the work area, check the connection of the power supply, related equipment, and the integrity of the metering pump. If there are any abnormalities or damages, promptly handle or replace them.

    • Select installation locationChoose a suitable location for installing the metering pump, taking into account the convenience of operation, pipeline connection, and maintenance needs. Choose a stable and away from chemicals or other hazardous substances.

    • Determine pipeline connection pointsAccording to the application requirements and the inlet and outlet requirements of the metering pump, determine the connection position with the pipeline to ensure that the inlet and outlet pipelines can be easily connected during the installation process.

    • Prepare brackets and connectorsBased on the size and weight of the metering pump, select appropriate installation brackets and connectors, such as bolts, support frames, pipe joints, valves, etc., to ensure that they have sufficient strength and stability.

  2. mounting bracketAccording to the design and specifications of the bracket, use bolts or other fixing devices to fix the bracket to the ground or wall. It is necessary to ensure that the bracket is installed firmly and can withstand the weight of the metering pump and the vibration generated during operation.

  3. Install pump bodyPlace the metering pump on the installation bracket, align it according to the design of the pump and bracket, and then use bolts or other fixing devices to fix the pump body on the bracket, ensuring that the pump body is installed firmly and will not loosen or shift.

  4. connecting pipe

    • Inlet connectionConnect the inlet of the pump to a liquid container or supply system, use a transparent and flexible suction pipe, and install a bottom valve and filter. If the liquid container is lower than the pump, an anti backflow valve or air release valve needs to be installed on the suction pipe to prevent siphon phenomenon.

    • Liquid outlet connectionConnect the outlet of the pump to the injection point or infusion system, use a white hard output tube, and install an injector and exhaust valve. If the injection point is higher than the pump, an anti back pressure valve or air release valve needs to be installed on the output pipe to prevent bending. Ensure that the pipeline connections are tight and take appropriate sealing measures to prevent leaks, while paying attention to the direction and bending of the pipeline to avoid excessive stretching or twisting.

  5. Install attachments and accessoriesInstall accessories and fittings according to actual needs, such as flow meters, pressure sensors, etc. Follow the installation guidelines for accessories and fittings to ensure that they are correctly connected to the metering pump.

  6. electrical connection

    • Connect to powerConnect the power cord of the pump to a power socket that meets its voltage and frequency requirements, and protect it with an air switch or fuse.

    • Grounding treatmentEnsure that the pump has a good grounding connection to prevent electric shock or interference.

    • functional connectivityIf remote control or signal input/output functions are required, the control interface of the pump can be connected to the corresponding equipment or system, such as pulse signals, analog signals, 485 signals, etc., and set and adjust according to the instructions.

  7. Adjustment and calibrationAccording to the provided operation manual and guidance, adjust the settings and parameters of the metering pump, such as speed, stroke length, and other related parameters, to achieve the required liquid flow rate and metering accuracy. During the adjustment and calibration process, pay attention to observing the operation of the metering pump. If there are any abnormalities, stop and check in a timely manner.

  8. Trial operation inspectionAfter installation, conduct a trial run of the pump to check for any abnormal conditions such as leakage, blockage, noise, vibration, etc


VYRON mechanical diaphragm metering pump automatic dosing pump GW series