The vehicle exhaust emission testing system can measure the concentrations of CO, CO2, NO, NO2, O2, THC emissions, as well as particulate matter, exhaust flow rate, navigation system data, environmental temperature and humidity, atmospheric pressure, and has functions such as testing process guidance, automatic calculation of total emissions, and export of test reports. The product adopts a modular design, and the portable battery supports a range of more than 6 hours, meeting the requirements of on-board emission testing for road vehicles.
Product Details

Vehicle exhaust emission testing systemProduct Introduction

Vehicle exhaust emission testing systemGasboard-9805 is a portable emission testing system developed by Sifang Instrument based on self-developed core gas analysis technology. It can measure the concentrations of CO, CO2, NO, NO2, O2, THC emissions, as well as particulate matter, exhaust flow rate, navigation system data, environmental temperature and humidity, atmospheric pressure, and has functions such as testing process guidance, automatic calculation of total emissions, and export of test reports. The product adopts a modular design, and the portable battery supports a range of more than 6 hours, meeting the requirements of on-board emission testing for road vehicles.


Product Features

Core gas analysis technology independently developed

Direct measurement of NO, NO2High precision, no need for conversion furnace, maintenance free in the later stage

Easy to operate and user-friendly

Easy to operate, supports testing process guidance, automatically calculates total emissions, exports test reports, and other functions

Modular design, flexible use
GAS module, PN module, PM module, and THC module can all be used separately to meet different measurement needs of customers

Strong endurance, meeting the requirements of on-board testing
The battery supports a range of more than 6 hours and can complete a complete actual driving pollutant emission test

Excellent performance, meeting national standard requirements

GB 18352.6-2016 "Limits and Measurement Methods for Pollutant Emissions from Light duty Vehicles (Six Stages)"

GB 17691-2018 "Limits and Measurement Methods for Pollutant Emissions from Heavy duty Diesel Vehicles (Six Stages)"

Good environmental adaptability
The system has good adaptability to the environment and is not affected by vehicle vibration, atmospheric pressure, and changes in environmental temperature and humidity


System Configuration


车载尾气排放测试系统



Technical Specifications

performance parameters
Gas analysis module measurement range C0:0~0.5~5%
CO2:0~5~20%
NO:0~3000ppm
NO2:0~1000ppm
O2:0~25%
THC:0~100~10000ppmC1
resolution CO2/O2:0.01%
CO/NO/NO2/THC:1ppm
precision ≤± 1% full scale (≥ 155ppm)
≤± 2% full scale (< 155ppm)
accuracy ≤± 2% reading or ≤ 0.3% full scale
Sensor response time
T10-90
≤2.5s
System response time
T0-90
≤10s
Zero drift (4 hours) CO:≤±50ppm
CO2:≤±1000ppm
NO/NO2:≤±5ppm
THC:≤±10ppmC1
Range drift (4 hours) CO: ≤± 2% reading or 50ppm
CO2: ≤± 2% reading or 1000ppm
NO/NO2: ≤± 2% reading or 5ppm
THC: ≤± 2% reading or 10ppmC1
PN measurement module measurement range 600~1.3*10⁹#/cm³
Particle size range 23nm~2500nm
accuracy ≤±10%
VPR efficiency ≥99%
Rise time T10-90 ≤3s
Exhaust flow meter range 65mm outer diameter: 10~600kg/h
85mm outer diameter: 100-2000kg/h
exhaust gas temperature -5~500℃
accuracy ≤± 2% reading or ± 1.0% of calibrated EFM * high flow rate
precision ≤ 1% of high traffic
linearity Determination coefficient R ²: ≥ 0.990, standard deviation SEE: ≤ 2% of full scale
Slope (al): 0.98-1.02, intercept coefficient (a0): ≤ 1% of full scale
Rise time T10-90 ≤1s
working parameters
Working environment temperature -10~40℃
working power supply 24VDC,AC220±10%(50Hz)
interface signal