Introduction to YAKS Explosion proof Motor
This series of motors complies with the provisions of GB3836.1-2010 "Explosive Atmosphere Part 1: General Requirements for Equipment" and GB3836.3-2010 "Explosive Atmosphere Part 3: Equipment Protected by Increased Safety Type" e "". At the same time, it complies with GB755-2000 "Rotating Electrical Machinery Rating and Performance", and the motor efficiency value meets the requirements of the national GB30254-2013 high-voltage three-phase cage asynchronous motor level 2 energy efficiency rating.
1. This series of electric motors is made into the increased safety ExeICT3 Gc, which is suitable for use in explosive environments composed of gas, vapor, or mist with ignition temperature of T3 group and air in factories.
2. This series of electric motors is mainly suitable for general mechanical equipment such as fans, water pumps, compressors, crushers, chip cutting machines, transportation machinery, and other similar mechanical equipment in explosive gas environments such as petroleum, chemical, coal, power stations, metallurgy, transportation, textiles, pharmaceuticals, and grain processing.
The meaning of YAKS increased safety explosion-proof motor model

YAKS 增安防爆电动机系列型谱
The corresponding relationship between the base, power, and speed of YAKS series motors (frame numbers 355-1000) (3kV, 6kV) IC81W (see Table 1).
Table 1
frame size | Synchronous r/min | ||||||||
3000 | 1500 | 1000 | 750 | 600 | 500 | 428 | 375 | 333 | |
| Power kW | |||||||||
|
1 2 355 3 4 5 |
185 200 220 250 280 |
185 200 220 250 280 |
185 200 | ||||||
|
1 2 400 3 4 5 |
315 355 400 450 |
315 355 400 450 |
220 250 280 315 355 |
185 200 220 250 280 |
185 200 | ||||
|
1 2 450 3 4 5 |
500 560 630 710 |
500 560 630 710 |
400 450 500 560 |
315 355 400 450 |
220 250 280 315 355 |
185 200 220 250 |
185 200 | ||
|
1 2 500 3 4 5 |
800 900 1000 1120 |
800 900 1000 1120 |
630 710 800 900 |
500 560 630 710 |
400 450 500 560 630 |
280 315 355 400 450 |
220 250 280 315 |
185 200 220 250 280 |
185 200 220 |
|
1 560 2 3 |
1250 1400 1600 |
1250 1400 1600 |
1000 1120 1250 |
800 900 1000 |
710 800 900 |
500 560 630 |
355 400 450 |
315 355 400 |
250 280 315 |
|
1 2 630 3 4 5 |
1800 2000 2240 2500 - |
1800 2000 2240 2500 - |
1400 1600 1800 2000 - |
1120 1250 1400 1600 1800 |
1000 1120 1250 1400 - |
710 800 900 1000 1120 |
500 560 630 710 800 |
450 500 560 630 710 |
355 400 450 500 560 |
|
1 2 710 3 4 5 |
2800 3150 3550 4000 - |
2800 3150 3550 - - |
2240 2500 2800 - - |
2000 2240 - - - | |||||
|
1 2 800 3 4 5 |
4500 5000 5600 - - |
4000 4500 5000 - - |
3150 3550 4000 4500 - |
2500 2800 3150 3550 - | |||||
|
1 2 900 3 4 5 |
- - |
5600 6300 7100 - - |
5000 5600 6300 - - |
4000 4500 5000 - - | |||||
|
1 2 1000 3 4 5 |
- - |
8000 9000 10000 - - |
7100 9000 - - - |
5600 6300 7100 8000 - | |||||
The corresponding relationship between YAKS series motors (frame numbers 355-1000) frame number, power, and speed (10kV) IC81W is shown in Table 2.
Table 2
frame size | Synchronous r/min | ||||||||
3000 | 1500 | 1000 | 750 | 600 | 500 | 428 | 375 | 333 | |
| power kW | |||||||||
|
1 2 3 450 4 5 6 7 8 9 10 |
200 220 250 280 315 355 400 450 500 560 — |
200 220 250 280 315 355 400 450 500 560 — |
— — — 200 220 250 280 315 355 400 |
— — — — — — 200 220 250 280 |
— |
— |
— |
— |
— |
|
1 2 3 500 4 5 6 |
630 710 800 900 1000 — |
630 710 800 900 1000 — |
450 500 560 630 710 — |
315 355 400 450 500 560 |
220 250 280 315 355 400 |
— — 220 250 280 |
— |
— |
— |
|
1 2 560 3 4 5 |
1120 1250 1400 — — |
1120 1250 1400 — — |
800 900 1000 1120 — |
630 710 800 900 — |
450 500 560 630 710 |
315 400 450 450 500 |
220 250 280 315 355 |
220 250 280 315 |
220 250 |
|
1 2 630 3 4 5 6 |
1600 1800 2000 — — — |
1600 1800 2000 2240 — — |
1250 1400 1600 1800 — — |
1000 1120 1250 1400 1600 — |
800 900 1000 1120 1250 — |
560 630 710 800 900 1000 |
400 450 500 560 630 710 |
355 400 450 500 560 630 |
280 315 355 400 450 500 |
|
1 2 710 3 4 5 |
2240 2500 2800 3150 - |
2500 2800 3150 - - |
2000 2240 2500 - - |
1800 2000 2240 - - | |||||
|
1 2 800 3 4 5 |
3550 4000 4500 5000 - |
3550 4000 4500 5000 - |
2800 3150 3550 - |
2500 2800 3150 - | |||||
|
1 2 900 3 4 5 |
- - - - - |
5600 6300 7100 - - |
4000 4500 5000 5600 - |
3550 4000 4500 5000 | |||||
|
1 2 1000 3 4 5 |
- - |
8000 9000 10000 - - |
6300 7100 8000 - - |
5600 6300 - - - | |||||
YAKS increased safety explosion-proof motor on-site operating conditions
a) The normal altitude of the electric motor shall not exceed 1000m.
b) The maximum ambient air temperature shall not exceed 40 ℃.
c) The minimum ambient air temperature should not be lower than -15 ℃, and the minimum ambient air temperature for sliding bearings or air-cooled motors should not be lower than 0 ℃.
d) Cooling water temperature of air-cooled motor: The cooling water temperature at the inlet of the cooler should not be higher than+25 ℃, nor should it be lower than+5 ℃. According to China's natural environment, if necessary, the cooling water temperature should not exceed+33 ℃
e) Tolerance values for voltage and frequency:
According to the provisions of GB 755, electric motors can operate continuously in Zone A (voltage within ± 5% of rated value, frequency within ± 2% of rated value) and achieve their basic functions, but their performance may differ from that at rated voltage and frequency (as shown in the rated points in Figure 2), and the temperature rise may be higher than that at rated voltage and frequency. If the motor operates on the boundary of region A, the temperature may exceed 10 ℃ at the rated point.
Electric motors can operate in region B (voltage within ± 10% of rated value, frequency within+3% to -5% of rated value) and achieve their basic functions, but their performance will differ more from rated voltage and frequency than motors operating in region A. The temperature rise may be higher than rated voltage and frequency, and is likely to be higher than region A. It is not recommended to continue operating on the boundary of region B.
The remaining electrical operating conditions of the electric motor shall comply with GB755.
Characteristics of YAKS increased safety explosion-proof electric motor products
The electric motor adopts the internationally popular box structure, and the base is welded with steel plates, which is lightweight and has good rigidity. A closed air/water cooler (YAKS) is installed on the top of the motor, and removing the cooler allows for observation or access to the interior of the motor, making installation and maintenance convenient.
The stator adopts an external pressure structure, and the stator winding adopts F-grade insulation material. The temperature rise is assessed according to B-grade, and the ends are reliably fixed and tied, and treated with vacuum pressure impregnation solvent-free paint process (VPI). Therefore, the insulation performance of the electric motor is excellent and reliable, with high mechanical strength and strong moisture resistance.
The rotor adopts a squirrel cage structure to improve accuracy and verify dynamic balance, ensuring smooth motor operation and minimal vibration.
According to different power and speed, there are two forms of bearings: rolling bearings and sliding bearings. The rolling bearings are equipped with non-stop oil injection and discharge devices at both ends, which can regularly replenish lubricating grease. The sliding bearings are end cover sliding bearings, which use forced oil supply lubrication, no pressure oil return, and measures to prevent shaft current generation are taken.
The protection level of the main junction box is IP54 (can also be made into IP55), usually installed on the right side of the motor (viewed from the motor spindle extension end), or can be installed on the left side of the motor according to the ordering requirements. The motor has three wiring terminals (U, V, W) and one grounding terminal, all of which are clamped and fixed on the wiring board. The wiring terminals adopt high-voltage insulated terminals, and the electrical clearance and creepage distance comply with the provisions of GB3836.3.
According to user requirements, temperature measuring devices can be added to important parts such as stator windings and bearings, and heaters can be installed inside the motor.
Introduction to YAKS Explosion proof Motor
This series of motors complies with the provisions of GB3836.1-2010 "Explosive Atmosphere Part 1: General Requirements for Equipment" and GB3836.3-2010 "Explosive Atmosphere Part 3: Equipment Protected by Increased Safety Type" e "". At the same time, it complies with GB755-2000 "Rotating Electrical Machinery Rating and Performance", and the motor efficiency value meets the requirements of the national GB30254-2013 high-voltage three-phase cage asynchronous motor level 2 energy efficiency rating.
1. This series of electric motors is made into the increased safety ExeICT3 Gc, which is suitable for use in explosive environments composed of gas, vapor, or mist with ignition temperature of T3 group and air in factories.
2. This series of electric motors is mainly suitable for general mechanical equipment such as fans, water pumps, compressors, crushers, chip cutting machines, transportation machinery, and other similar mechanical equipment in explosive gas environments such as petroleum, chemical, coal, power stations, metallurgy, transportation, textiles, pharmaceuticals, and grain processing.
The meaning of YAKS increased safety explosion-proof motor model

YAKS 增安防爆电动机系列型谱
The corresponding relationship between the base, power, and speed of YAKS series motors (frame numbers 355-1000) (3kV, 6kV) IC81W (see Table 1).
Table 1
frame size | Synchronous r/min | ||||||||
3000 | 1500 | 1000 | 750 | 600 | 500 | 428 | 375 | 333 | |
| Power kW | |||||||||
|
1 2 355 3 4 5 |
185 200 220 250 280 |
185 200 220 250 280 |
185 200 | ||||||
|
1 2 400 3 4 5 |
315 355 400 450 |
315 355 400 450 |
220 250 280 315 355 |
185 200 220 250 280 |
185 200 | ||||
|
1 2 450 3 4 5 |
500 560 630 710 |
500 560 630 710 |
400 450 500 560 |
315 355 400 450 |
220 250 280 315 355 |
185 200 220 250 |
185 200 | ||
|
1 2 500 3 4 5 |
800 900 1000 1120 |
800 900 1000 1120 |
630 710 800 900 |
500 560 630 710 |
400 450 500 560 630 |
280 315 355 400 450 |
220 250 280 315 |
185 200 220 250 280 |
185 200 220 |
|
1 560 2 3 |
1250 1400 1600 |
1250 1400 1600 |
1000 1120 1250 |
800 900 1000 |
710 800 900 |
500 560 630 |
355 400 450 |
315 355 400 |
250 280 315 |
|
1 2 630 3 4 5 |
1800 2000 2240 2500 - |
1800 2000 2240 2500 - |
1400 1600 1800 2000 - |
1120 1250 1400 1600 1800 |
1000 1120 1250 1400 - |
710 800 900 1000 1120 |
500 560 630 710 800 |
450 500 560 630 710 |
355 400 450 500 560 |
|
1 2 710 3 4 5 |
2800 3150 3550 4000 - |
2800 3150 3550 - - |
2240 2500 2800 - - |
2000 2240 - - - | |||||
|
1 2 800 3 4 5 |
4500 5000 5600 - - |
4000 4500 5000 - - |
3150 3550 4000 4500 - |
2500 2800 3150 3550 - | |||||
|
1 2 900 3 4 5 |
- - |
5600 6300 7100 - - |
5000 5600 6300 - - |
4000 4500 5000 - - | |||||
|
1 2 1000 3 4 5 |
- - |
8000 9000 10000 - - |
7100 9000 - - - |
5600 6300 7100 8000 - | |||||
The corresponding relationship between YAKS series motors (frame numbers 355-1000) frame number, power, and speed (10kV) IC81W is shown in Table 2.
Table 2
frame size | Synchronous r/min | ||||||||
3000 | 1500 | 1000 | 750 | 600 | 500 | 428 | 375 | 333 | |
| power kW | |||||||||
|
1 2 3 450 4 5 6 7 8 9 10 |
200 220 250 280 315 355 400 450 500 560 — |
200 220 250 280 315 355 400 450 500 560 — |
— — — 200 220 250 280 315 355 400 |
— — — — — — 200 220 250 280 |
— |
— |
— |
— |
— |
|
1 2 3 500 4 5 6 |
630 710 800 900 1000 — |
630 710 800 900 1000 — |
450 500 560 630 710 — |
315 355 400 450 500 560 |
220 250 280 315 355 400 |
— — 220 250 280 |
— |
— |
— |
|
1 2 560 3 4 5 |
1120 1250 1400 — — |
1120 1250 1400 — — |
800 900 1000 1120 — |
630 710 800 900 — |
450 500 560 630 710 |
315 400 450 450 500 |
220 250 280 315 355 |
220 250 280 315 |
220 250 |
|
1 2 630 3 4 5 6 |
1600 1800 2000 — — — |
1600 1800 2000 2240 — — |
1250 1400 1600 1800 — — |
1000 1120 1250 1400 1600 — |
800 900 1000 1120 1250 — |
560 630 710 800 900 1000 |
400 450 500 560 630 710 |
355 400 450 500 560 630 |
280 315 355 400 450 500 |
|
1 2 710 3 4 5 |
2240 2500 2800 3150 - |
2500 2800 3150 - - |
2000 2240 2500 - - |
1800 2000 2240 - - | |||||
|
1 2 800 3 4 5 |
3550 4000 4500 5000 - |
3550 4000 4500 5000 - |
2800 3150 3550 - |
2500 2800 3150 - | |||||
|
1 2 900 3 4 5 |
- - - - - |
5600 6300 7100 - - |
4000 4500 5000 5600 - |
3550 4000 4500 5000 | |||||
|
1 2 1000 3 4 5 |
- - |
8000 9000 10000 - - |
6300 7100 8000 - - |
5600 6300 - - - | |||||
YAKS increased safety explosion-proof motor on-site operating conditions
a) The normal altitude of the electric motor shall not exceed 1000m.
b) The maximum ambient air temperature shall not exceed 40 ℃.
c) The minimum ambient air temperature should not be lower than -15 ℃, and the minimum ambient air temperature for sliding bearings or air-cooled motors should not be lower than 0 ℃.
d) Cooling water temperature of air-cooled motor: The cooling water temperature at the inlet of the cooler should not be higher than+25 ℃, nor should it be lower than+5 ℃. According to China's natural environment, if necessary, the cooling water temperature should not exceed+33 ℃
e) Tolerance values for voltage and frequency:
According to the provisions of GB 755, electric motors can operate continuously in Zone A (voltage within ± 5% of rated value, frequency within ± 2% of rated value) and achieve their basic functions, but their performance may differ from that at rated voltage and frequency (as shown in the rated points in Figure 2), and the temperature rise may be higher than that at rated voltage and frequency. If the motor operates on the boundary of region A, the temperature may exceed 10 ℃ at the rated point.
Electric motors can operate in region B (voltage within ± 10% of rated value, frequency within+3% to -5% of rated value) and achieve their basic functions, but their performance will differ more from rated voltage and frequency than motors operating in region A. The temperature rise may be higher than rated voltage and frequency, and is likely to be higher than region A. It is not recommended to continue operating on the boundary of region B.
The remaining electrical operating conditions of the electric motor shall comply with GB755.
Characteristics of YAKS increased safety explosion-proof electric motor products
The electric motor adopts the internationally popular box structure, and the base is welded with steel plates, which is lightweight and has good rigidity. A closed air/water cooler (YAKS) is installed on the top of the motor, and removing the cooler allows for observation or access to the interior of the motor, making installation and maintenance convenient.
The stator adopts an external pressure structure, and the stator winding adopts F-grade insulation material. The temperature rise is assessed according to B-grade, and the ends are reliably fixed and tied, and treated with vacuum pressure impregnation solvent-free paint process (VPI). Therefore, the insulation performance of the electric motor is excellent and reliable, with high mechanical strength and strong moisture resistance.
The rotor adopts a squirrel cage structure to improve accuracy and verify dynamic balance, ensuring smooth motor operation and minimal vibration.
According to different power and speed, there are two forms of bearings: rolling bearings and sliding bearings. The rolling bearings are equipped with non-stop oil injection and discharge devices at both ends, which can regularly replenish lubricating grease. The sliding bearings are end cover sliding bearings, which use forced oil supply lubrication, no pressure oil return, and measures to prevent shaft current generation are taken.
The protection level of the main junction box is IP54 (can also be made into IP55), usually installed on the right side of the motor (viewed from the motor spindle extension end), or can be installed on the left side of the motor according to the ordering requirements. The motor has three wiring terminals (U, V, W) and one grounding terminal, all of which are clamped and fixed on the wiring board. The wiring terminals adopt high-voltage insulated terminals, and the electrical clearance and creepage distance comply with the provisions of GB3836.3.
According to user requirements, temperature measuring devices can be added to important parts such as stator windings and bearings, and heaters can be installed inside the motor.