FLUX-CHECK 250fluxmeter
FLUX-CHECK 250fluxmeter
compactfluxmeterAs a handheld measuring device used for measuring magnetic flux
Compact List MagnitikFLUX-CHECK 250A magnetometer is a handheld instrument of this size used to measure the magnetic flux Φ (Phi) of a magnet system or individual magnet.
Understanding the quality and magnetization of permanent magnets or magnetic systems is crucial. The use of a magnetometer to measure magnetic field strength can only be done at specific points, without considering the volume of the magnet. This task is carried out by a device equipped with a Helmholtz coilfluxmeterExecution.
By combining the List Magnitik Helmholtz torque coil HM-2, the magnetic flux of the permanent magnet can be accurately determined, as the entire volume of the magnet can be measured regardless of its position. The influence of magnets on coils is measured by voltage and converted into magnetic flux values. All types of coils or coil probes can be connected to the instrument, except for the Helmholtz HM-2 torque coil.
Recording the pulse curve of flow measurement will result in an area, which is integrated to give the flow value. This area is displayed graphically on an LCD touch screen with a resolution of 320x480 pixels, and the correct luminous flux value is calculated based on it. Technically speaking, FLUX-CHECK 250 is an electronic analog voltage integrator.
manyfluxmeterThe drift displayed after the connection results in a longer waiting time before the next measurement, or compensation must be made over and over again during the measurement series, which does not occur with FLUX-CHECK 250. Enter a trigger value and start measuring from that value, with the previous drift value automatically set to zero. The instrument can be used for measurement after being turned on.
In addition to the magnetic flux Φ, other information about the coil and the measured magnet can also be stored in the instrument and used to calculate other information:
The number of turns of the coil (n) - used to calculate the "actual magnetic flux".
The coil constant of the Helmholtz coil - used to calculate the 'magnetic moment'.
Volume of magnet - used to calculate magnetic flux density B
It provides flexible data storage, digital and analog combined display, and peak to peak measurement. The Bluetooth interface allows data transfer to Windows PCs as well as applications for Android and iOS. The USB-C interface allows connection to external power sources.
The SCPI interface has been implemented on the device, allowing it to perform remote measurements and provide measurement values during online operations. Connecting through USB also ensures power supply and continuous operation.
To further process the measurement data, you can pair the measurement device with mobile Android and iOS devices. Or you can communicate with a Windows PC. This is achieved through low-power Bluetooth technology (BLE). UseLima ConnectThe application allows you to manage projects and assign measurement points on photos. The measurement results can be statistically evaluated and displayed in graphical form. The applications for Android, iOS, and Windows are free.

fluxmeterTechnical data of FLUX-CHECK 250 | |
| unit of measurement | Magnetic flux mVs (millivolt seconds, corresponding to SI unit mWb/milli Weber) Measurement range: 0-10 mV and 0-250 mV, automatic or manual range switching Actual magnetic flux: mV/n Magnetic moment: mVs * cm Magnetic flux density: A/cm or mT |
| Accuracy: | 2% |
| Repeatability: | 1% |
| Resolution: | 0.001 millivolts |
| Input resistance: | 33 kiloohms |
| Environmental temperature range: | 0-50 ° C |
| Display: | LCD touch screen color 320x480 pixels |
| Multilingual menu navigation: | German, English, Italian, French, Spanish |
| data logger: | 10000 measurements, flexible segmentation |
| statistics: | Count/value/small value/mean/standard deviation |
| interface | Bluetooth low-power interface for communication with Android, iOS, and Windows |
| Applications for Android, iOS, and Windows: | Free through Google Play Store, Apple App Store, and List Magnitik website |
| External control: | Through USB-C and SCPI communication interfaces |
| power supply | 3x 1.5 V AA Minon. Can be connected to an external power source through USB-C |
| Business Hours: | Approximately 25 hours of battery usage, with no limitations when using an external power source |
| Size: | 150 x 85 x 35 millimeters |
| Weight: | 320 grams (including battery) |
The Helmholtz torque coil HM-1 is a coil made of a plastic cylinder with an inner diameter of 90 mm, which can be used in FLUX-CHECK 250fluxmeterMeasure the magnetic flux of the magnet. The position of the magnet can be seen from all directions through the observation hole.
The Helmholtz coil is a special coil structure that can generate a uniform magnetic field. The radius and distance between two coils must be the same. The magnetic fields of the two coils are superimposed, resulting in an almost uniform magnetic field along the imaginary axis between the centers of the coils in the central region.
Technical Table Helmholtz Torque Coil HM-1 | |
| inner diameter | 90 millimeters |
| outer diameter | 110 millimeters |
| Uniform measurement range: | 35 millimeters |
| Number of windings: | Two 600 |
| Coil constant: | 0.0096 centimeters |
| connector | 2 banana sockets |
The Helmholtz torque coil HM-2 is a double coil made of aluminum with an inner diameter of 49 mm. You can use it in FLUX-CHECK 250fluxmeterMeasure the magnetic flux of the magnet.
Technical Table Helmholtz Torque Coil HM-2 | |
| inner diameter | 49 millimeters |
| outer diameter | 80 millimeters |
| Uniform measurement range: | 29 millimeters |
| Number of windings: | Two 400 |
| Coil constant: | 0.01374 centimeters |
| connector | 2 banana sockets |
![]() |
![]() |