| input | Input Voltage | Three phase 380V ± 15% |
| frequency | 47-63HZ | |
| output | external characteristics | Constant voltage CV |
| rated output voltage | 28.5V | |
| Output voltage range | 0~35V | |
| output current | Choose from 0 to 2000A | |
| Current range | 0~105% rated output current | |
| Maximum starting current | 2400A | |
| source voltage effect | <±0.1% | |
| loading effect | <± 0.2% (resistive load) | |
| Effective value of full load ripple | <±0.5% | |
| high frequency noise | <±2% | |
| Load response time | 1ms | |
| efficiency | >90% @ 100% load | |
| display | Digital Voltmeter | (4 1/2) 规格: ±0.5%rdg+2digit |
| digital ammeter | (4 1/2) 规格: ±0.5%rdg+2digit | |
| working conditions | Storage temperature | -40℃~+60℃ |
| Operating Temperature | -20-46 ℃ (general military type) -25-55 ℃ (foreign trade type) | |
| relative humidity | ≤ 95% (no condensation) | |
| Protection level | IP20 | |
| atmospheric pressure | 80-106KPc (altitude below 2000m) | |
| noise | < 65 dB at 1 meter | |
| protect | Input phase loss protection | Model of three-phase input |
| Overvoltage protection setting | 3V to 110% rated maximum voltage, automatic protection and alarm in case of overvoltage | |
| Output overcurrent protection | If the current exceeds 850A, the power supply will automatically shut down after 5 seconds of operation and resume normal output after 10 seconds. It can continuously protect the self starting conversion. | |
| short circuit protection | The output terminal can be short circuited for a long time, and there will be sound and light alarms when the short circuit is resolved. After the short circuit is resolved, the power supply will automatically resume normal operation | |
| overheat protection | >Operated at 85 ℃, it can automatically restore output after the overheating is resolved | |
| reliability | Mean time between failures: greater than 20000 hours | |
| Insulation requirements | Dielectric Strength | Input shell AC2000V/1 minute, leakage current less than 10mA |
| Input to output AC1500V/1 minute, leakage current less than 10mA | ||
| insulation resistance | Input to shell, input to output: DC1000V, greater than 100M Ω | |
| Output to shell: DC500V, greater than 100M Ω | ||
| cooling system | Forced fan cooling | |
| Lead voltage drop compensation | Equipped with automatic lead voltage drop compensation function | |
| chassis | Three defense requirements | All components comply with national and military standards |
| Requirements for impact and vibration | Compliant with national and military standards | |
| Dimensions (width x height x inner depth) mm | Depending on power | |
| weight | Depending on power | |
| Optional accessories | 1. Aircraft Ground Connector (PJD-450HT) | |
| 2.航空电缆 (10m,15m,20m) | ||
| model | Specifications |
| NHZDY28-10 | DC28V 10A |
| NHZDY28-30 | DC28V 30A |
| NHZDY28-50 | DC28V 50A |
| NHZDY28-100 | DC28V 100A |
| NHZDY28-150 | DC28V 150A |
| NHZDY28-200 | DC28V 200A |
| NHZDY28-300 | DC28V 300A |
| NHZDY28-500 | DC28V 500A |
| NHZDY28-1000 | DC28V 1000A |
| NHZDY28-1500 | DC28V 1500A |