| communication input |
Below 15KW (single-phase 110V ± 10%, 220V ± 10%, or three-phase 380V ± 15%) Above 15KW (three-phase 380V ± 15%) Frequency: 50HZ, 60HZ, 400HZ optional Also compatible with DC input: Single phase: AC220V (range 176-264) V, frequency (45-450) Hz, corresponding to DC (250-370) V;
Three phase: AC380V (range 330-430V), frequency 50Hz, corresponding to DC (450-600V);
|
|
| DC output |
Voltage (stabilized value CC): (0-100% rated value) V continuously adjustable (up to 6000V) Current (constant current value CV): (0-100% rated value) A continuously adjustable (up to 5000A) |
|
| source voltage effect | ≤ 0.2% effective value | |
| loading effect |
Voltage stabilization accuracy: ≤ 0.5% effective value(Resistive load) Constant current accuracy: ≤ 0.5% effective value(Resistive load) |
|
| Output ripple | Voltage stabilization state (CC): ≤ 0.3%+10mV (rms) (effective value) | |
| Steady current state (CV): ≤ 0.5%+10mA (rms) (effective value) | ||
| output display | 4 and a half digit table accuracy: ± 1%+1 word | |
| Display format 00.00V-19.99V; 000.0V-199.9V; 0000V-1999V; | ||
| Voltage and current setting | Multi turn potentiometer, button type, LCD touch screen (optional) | |
| Overvoltage protection | Built in O.V.P protection, with a protection value of+5% of the rated value. After protection, the output is turned off and unlocked when restarted | |
| overcurrent protection | Overload, short circuit, constant current output | |
| overheat protection | Built in O.T.P protection, with a protection value of 85 ℃± 5% (radiator temperature). After protection, the output is turned off,After the overheating is relieved, the output can be automatically restored | |
| output polarity | Output positive (+) and negative (-) can be grounded at will (positive and negative pole flashlights or automatic reversing function can be installed) | |
| Dielectric Strength |
Input shell AC2000V/1 minute, leakage current less than 10mA
Input to output AC1500V/1 minute, leakage current less than 10mA
|
|
| insulation resistance |
Input to shell, input to output: DC1000V, greater than 100M Ω
Output to shell: DC500V, greater than 100M Ω
|
|
| cooling method | Forced air cooling | |
| operating environment | Indoor usage design, temperature range: -5 ℃ to 50 ℃; Humidity: 10% to 85% RH | |
| storage environment | Temperature: -20 ℃ to 70 ℃; Humidity: 10% to 90% RH | |
| atmospheric pressure | 70-106KPa (altitude below 2000m) | |
| Protection level | IP20 | |
| mean time between failures | ≥50000H | |
| efficiency | >90% (running at full load) | |
| execution standard | ||
| optional |
1External control function: optional 20-5V、 0-10V or4-20mA analog PLCOutput voltage and current of signal controlled power supply 2. SamplingFunction:output voltage and currentTwo samples can be taken0-5V、 0-10V or4-20mA analog PLCsignal 3Timer function: optional timer cycle on/off and operation; 4. Remote compensation function:Can provide remote sampling function for positive and negative electrodes to reduce voltage drop on the wire 5. Remote control power on/off function: can provide 5V level signal input port to control power on/off 6. Communication function:Optional RS485, RS232, GPIB, USB and other data interfaces can be used to connect and control with a computer. The working status of the power supply can be controlled through monitoring software (one computer can control 250 power supplies) |
|