1. Explosion proof axial fan is composed of explosion-proof motor, blades, air duct and other components; Both cable and steel pipe wiring are acceptable; Installation forms: fixed position, pipeline, and wall mounted; $r $n400 diameter square explosion-proof exhaust fan
Scope of application:400 diameter square explosion-proof exhaust fan
Dangerous areas in Zone 1.1 and Zone 2;
2. Class IIA and IIB explosive gas environment.
Product Features:
1. Explosion proof axial fan is composed of explosion-proof motor, blades, air duct and other components;
2. Cable or steel pipe wiring is acceptable;
3. Installation forms: fixed position, pipeline, and wall mounted;
4. Meet the requirements of GB3836-200 and IEC60079 standards.
Main technical parameters:
1. Explosion proof mark: Exd Ⅱ BT4
2. Protection, etc.: IP54
3. Anti corrosion measures: WF1
4. Rated voltage: AC220V/380V
5. Spindle speed: 1450r/min
6. Cable specifications: Φ 10mm to Φ 14mm
7. Inlet thread: G3/4 "
8. Impeller diameter/power/air volume/weight:
300mm/0.25KW/2280m3/h/16Kg
400mm/0.37KW/2880 m3/h/19Kg
500mm/0.55KW/5900 m3/h/23Kg
600mm/0.75KW/8700 m3/h/28Kg
Scope of application:
Dangerous areas in Zone 1.1 and Zone 2;
2. Class IIA and IIB explosive gas environment.
Product Features:
1. Explosion proof axial fan is composed of explosion-proof motor, blades, air duct and other components;
2. Cable or steel pipe wiring is acceptable;
3. Installation forms: fixed position, pipeline, and wall mounted;
4. Meet the requirements of GB3836-200 and IEC60079 standards.
Main technical parameters:400 diameter square explosion-proof exhaust fan
1. Explosion proof mark: Exd Ⅱ BT4
2. Protection, etc.: IP54
3. Anti corrosion measures: WF1
4. Rated voltage: AC220V/380V
5. Spindle speed: 1450r/min
6. Cable specifications: Φ 10mm to Φ 14mm
7. Inlet thread: G3/4 "
8. Impeller diameter/power/air volume/weight:
300mm/0.25KW/2280m3/h/16Kg
400mm/0.37KW/2880 m3/h/19Kg
500mm/0.55KW/5900 m3/h/23Kg
600mm/0.75KW/8700 m3/h/28Kg