When the impeller of the 9-19 high-pressure centrifugal fan rotates, due to the centrifugal force, the wind vane drives the gas to move forward and outward, forming a series of spiral movements. The air between the impeller blades accelerates and rotates in a spiral shape, squeezing the gas outside the pump body into the side groove (sucked in through the suction port). When it enters the side channel, the gas is compressed and then returns to accelerate and rotate between the impeller blades again. When air passes through the impeller and side groove along a spiral trajectory, each impeller blade increases the degree of compression and acceleration. As the rotation progresses, the kinetic energy of the gas increases, further increasing the pressure of the gas passing through the side channel. When the air reaches the connection point between the side groove and the discharge flange (the side channel narrows at the outlet), the gas is squeezed out of the blades and discharged from the pump body through the outlet muffler.
II5.5kw right-handed 90 degree drying equipment matched with high-pressure centrifugal fanModel and parametersPrecautions
1. Installation location - It must be installed indoors in a place that is not affected by wind and rain
2. Environmental temperature below -40 ℃
3. Relative humidity below -80%
4. Air quality - If the air contains corrosive or flammable gases such as acids and alkalis, it should not be transported by high-pressure blowers to avoid danger
5. Dust protection - Avoid using in places with large amounts of dust, powder, or fibers. If it is necessary to use in such places, please install a filter and regularly clean the dust attached to the filter and inside the high-pressure blower
6. Ventilation and heat dissipation - Please choose to use it in a well ventilated place and not in a sealed room or box
use
7. Placement space - For the convenience of column maintenance or repair, please avoid installing in overly narrow locations
8. Avoid vibration - Please install in a vibration free location; If vibration in the venue is unavoidable, anti vibration measures must be installed
Measures to prevent damage to the high-pressure blower caused by external vibrations
III90 degree right-handed drying equipment matched with high-pressure centrifugal fanApplication Industry
1. Industrial vacuum cleaner 2 Filling equipment 3 Central feeding system 4 Cleaning and drying equipment 5 Textile Machinery 6 Screen transfer printing equipment 7 Woodworking Machinery 8 Electroplating equipment 9. PCB board equipment 10 Laser equipment 11 Swimming Pool Equipment 12 Tunnel Engineering 13 Leather cutting equipment 14 Powder conveying 15 Printing equipment.
490 degree right-handed drying equipment matched with high-pressure centrifugal fanindustryterm
1. Traffic
The flow rate of the 9-19 high-pressure centrifugal fan refers to the volume of gas flowing through the fan per unit time. The units include m3/h, m3/min, and m3/s. In China, it is customary to use m3/h for ventilation fans and m3/min for blowers, but m3/s is mostly used in the design and performance calculation of ventilation fans. It must be noted that the volumetric flow rate of high-pressure centrifugal fans specifically refers to the volumetric flow rate at the "inlet" of the ventilation fan, because the pressure on each flow section of the ventilation fan is different, and the volumetric flow rate flowing through each flow section will also be different accordingly.
2. Full pressure
The total pressure of the 9-19 type high-pressure centrifugal fan is defined as the difference between the total pressure on the outlet section and the total pressure on the inlet section of the fan. The total pressure of an airflow at a certain point or section is equal to the sum of the dynamic pressure and static pressure at that point or section.
3. Dynamic pressure
The dynamic pressure of a high-pressure centrifugal fan is defined as the pressure represented by the kinetic energy of the gas at the outlet section of the fan. Or: Dynamic pressure is
The pressure required to accelerate a gas from zero velocity to a certain velocity.
The dynamic pressure is directly proportional to the kinetic energy of the airflow
Dynamic pressure only acts on the direction of airflow and is always positive
Pd=0.5 ×ρV%*p2%*p%*b
In the formula, Pd=dynamic pressure Pa ρ=gas density kg/m% * p3% * p% * b V=velocity m/s
4. Static pressure
The static pressure of the 9-19 type high-pressure centrifugal fan is defined as the total pressure of the fan minus the dynamic pressure of the fan. In fact, static pressure is the pressure difference between a certain point in the airflow or a space filled with gas and atmospheric pressure. When the pressure at that point is higher than atmospheric pressure, it is a positive value, and when it is lower than atmospheric pressure, it is a negative value. Static pressure energy acts in all directions of a gas, independent of velocity, and is a measure of the potential in the gas. Ps=P%*p%*pt%*b-Pd; In the formula, Ps=static pressure Pa; Pt=total pressure Pa; Pd=dynamic pressure Pa.
5. Shaft power
The shaft power of a high-pressure centrifugal fan refers to the actual power required by the fan. It includes the internal power of the fan and the mechanical losses of the bearings and transmission devices. The shaft power, also known as the input power of the ventilation fan, is actually the output power of the motor.
Fan parameter table
| model | air volume | wind pressure | speed | power | weight |
| 9-19-4A | 824~1209m3/h | 3660~3720pa | 2900rpm | 2.2kw | 70kg |
9-19-4.5A drying equipment is equipped with a high-pressure centrifugal fanAll of them are single suction, usually with 13 machine numbers ranging from 4A to 16A. The fan is usually made in two forms: right-handed and left-handed.
fan structure
The fan is mainly composed of impeller, casing, air inlet, bracket, etc
♦ Impeller: The fan has 12 blades;
♦ Chassis:Weld ordinary steel plates into a snail shaped shell as a whole;
♦ Air inlet:Make a convergent streamlined overall structure and fix it on the front cover plate with bolts;
♦ Transmission group: composed of main shaft, bearing box, coupling, etc. The spindle is made of high-quality steel and the bearing housing has an overall structure. Using rolling bearings, rolling shafts9-19-4.5A drying equipment is equipped with a high-pressure centrifugal fanInstallation precautions
1. Installation location: It must be installed indoors in a place that is not affected by wind and rain
2. Environmental temperature: below 40 ℃
3. Relative humidity: below 80%
4. Air quality: If the air contains corrosive or flammable gases such as acids and alkalis, high-pressure blowers should not be used for transportation to avoid danger. Explosion proof fans can be selected.
5. Dust protection: Avoid using in places with large amounts of dust, powder, or fibers. If it is necessary to use in such places, please install a filter and regularly clean the dust attached to the filter and inside the high-pressure blower
6. Ventilation and heat dissipation: Please choose to use it in a well ventilated place and not in a sealed room or box
7. Placement space: For the convenience of column maintenance or repair, please avoid installing in overly narrow locations
8. Avoid vibration: Please install in a vibration free location; If the vibration in the venue is unavoidable, anti vibration measures must be installed to prevent the high-pressure blower from being damaged by external vibrations.
Fan maintenance and storage
The usage environment should be kept clean regularly, the surface of the fan should be kept clean, and there should be no debris at the inlet and outlet. Regularly remove dust and other debris from the fan and pipeline.
► It can only be operated under safe and normal conditions of the wind turbine, while ensuring sufficient capacity and stable voltage of the power supply facilities. It is strictly prohibited to operate without phase. The power supply line must be a line and temporary power supply should not be used.
During the operation of the fan, if abnormal noise, severe motor heating, live casing, switch tripping, inability to start, etc. are found, the fan should be stopped immediately for inspection. To ensure safety, do not operate the fan for maintenance during operation. After inspection, a trial run should be conducted for about five minutes to confirm that there are no abnormal phenomena before starting the machine.