Welcome Customer !

Membership

Help

Shandong Tianhe Environmental Technology Co., Ltd
Custom manufacturer

Main Products:

hbzhan>Products

Shandong Tianhe Environmental Technology Co., Ltd

  • E-mail

    wangyingying@yunjingtianhe.com

  • Phone

    13276363312

  • Address

    Room 206, Building 1, Weifang High tech Zone Optoelectronic Industry Accelerator (Phase I), No. 155 Optical Circuit, Weifang High tech Zone, Shandong Province

Contact Now

Atmospheric electric field monitoring instrument

NegotiableUpdate on 02/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The atmospheric electric field monitor continuously detects the strength of the atmospheric electric field, records the trend of electric field changes, supports uploading data to the cloud monitoring platform via 4G network, and achieves remote real-time monitoring. When the electric field strength reaches the preset threshold, the device automatically sends out a warning signal, indicating possible lightning activity, and the warning time can be advanced by 5-30 minutes.
Product Details

Atmospheric electric field monitoring instrumentContinuously monitor the atmospheric electric field strength, record the trend of electric field changes, support uploading data to the cloud monitoring platform via 4G network, and achieve remote real-time monitoring. When the electric field strength reaches the preset threshold, the device automatically sends out a warning signal, indicating possible lightning activity, and the warning time can be advanced by 5-30 minutes.

大气电场监测仪

1、 Application Environment Description

Atmospheric electric field monitoring instrumentIt is a high-precision lightning monitoring and warning device that can monitor real-time changes in the electric field in the atmosphere, accurately capture the traces of lightning activity, and provide strong support for the prevention of lightning disasters.

In the field of meteorological monitoring, atmospheric electric field meters can be widely used in meteorological stations to continuously and uninterrupted monitor lightning activity in the region, providing key data for weather forecasting and meteorological disaster warning. By analyzing changes in atmospheric electric fields, meteorological departments can predict the probability, intensity, and development trend of lightning weather in advance, issue lightning warning signals in a timely manner, and provide important reference for the safe operation of the public, aviation, navigation, and other industries.

For various places that are susceptible to lightning strikes, such as petrochemical enterprises, communication base stations, power facilities, high-rise buildings, etc., atmospheric electric field meters can be used as important monitoring tools for lightning protection. Installing atmospheric electric field meters around these places can monitor the dynamic changes of the surrounding atmospheric electric field in real time. When the strength of the atmospheric electric field exceeds the preset threshold, an alarm can be triggered in a timely manner to remind staff to take corresponding protective measures, such as stopping outdoor operations and shutting down key equipment, effectively reducing the losses caused by lightning disasters to personnel safety and equipment and facilities.

In addition, atmospheric electric field meters also have certain application value in industries such as agriculture and forestry. In agricultural production, knowing lightning weather information in advance is helpful for arranging agricultural activities reasonably, avoiding crop losses caused by lightning weather, and also ensuring the safety of agricultural workers. In forestry, atmospheric electric field instruments can be used to monitor lightning activity, prevent forest fires caused by lightning strikes, and provide protection for forest resources.

2、 Technical performance and specifications

1. Technical parameters

range -100kv/m——100kv/m
precision ±0.001%F.S
response time 3s
Shell material 6061 aluminum alloy
power supply voltage 12VDC( 0.5W@12V )
contact method Modbus-485


2. Dimensional drawing

大气电场监测仪

3、 Installation and electrical connections

1. Installation

1.1: This product belongs to a relatively precise instrument and should avoid phenomena such as falling and impact.

1.2: The equipment should avoid high temperatures, pay attention to waterproofing, and prevent icing;

1.3: The unpacked instrument should be stored in a dry, ventilated, and non corrosive gas free place. When handling, it should be handled with care and avoid severe vibration. Dust, moisture, and drastic temperature changes can affect the service life of this product, so avoid placing it in these areas.

The equipment should have good grounding during use

2. Electrical installation

The cable is a 4-core shielded wire, and the line sequence is defined as follows:

1- Red - Power cord (12~24VDC)

2- Blue - Ground (GND)

3-Green-485B

4-Yellow-485A