Axial edge electric contact pressure gauge YXC-100ZT 0-1MPastructural principle
The instrument consists of a measuring system, an indicating device, a magneto electric contact device, a housing, an adjusting device, and a junction box (plug socket).
The working principle of the instrument is based on the spring tube in the measurement system, which is forced to produce corresponding elastic deformation displacement at the end of the spring tube under the pressure of the measured medium. With the help of the connecting rod and the transmission of the gear transmission mechanism, it is amplified and the measured value is gradually indicated on the dial by the indicator pointer (together with the contact) fixed on the gear shaft. At the same time, when it comes into contact with the contact point (upper or lower limit) on the set pointer (dynamic breaking or dynamic closing), it causes the circuit in the control system to be disconnected or connected, in order to achieve automatic control and send alarm signals.
Axial edge electric contact pressure gauge YXC-100ZT 0-1MPaModel designation
Y |
X |
C |
Specifications |
content |
|||||
|
Instrument category : pressure gauge |
Control method : Slow moving contact position switch |
Contact form of contact device : Magnetic assisted action type |
A |
Suitable for ammonia and its mixtures |
|||||
G |
Equipped with isolation device |
||||||||
- |
|||||||||
|
ceremony table public call, name, say, weigh straight path and type formula |
100 and 150 respectively represent radial formulas with diameters of 100 and 150mm |
||||||||
102 represents a diameter of 100mm towards the rear edge |
|||||||||
103 and 153 respectively represent axial embedded types with diameters of 100 and 150mm |
|||||||||
B |
|||||||||
- |
|||||||||
Other functions |
F - Corrosion resistance; Z-anti vibration; FZ Corrosion and Vibration Resistance |
||||||||
Y |
X |
C |
□ |
- |
□ |
B |
- |
□ |
|
Main technical indicators and functions
Scale range, accuracy level, and joint thread size
type |
model |
name |
Scale range MPa |
Accuracy class |
threaded joint |
||
instruction |
set value |
||||||
connect |
disconnect |
||||||
普通型 |
YXC-100 *YXC-102 YXC-103 |
Magnetic assisted electric contact pressure gauge |
0-0.6 to 60 and -0.1-0.06 to 2.4 series |
1.5 |
1.5 |
4 |
M20×1.5 |
|
YXC-150 *YXC-153 |
0-0.1 to 60 and -0.1-0 to 2.4 series |
||||||
type |
YXCA-150 |
Magnetic assisted electric contact ammonia pressure gauge |
0-0.16 to 60 and -0.1-0.06 to 2.4 series |
2.5 |
2.5 |
4 |
|
Anti vibration mode |
YXC-100-Z *YXC-102-Z YXC-103-Z |
Magnetic assisted electric contact pressure gauge |
0~0.6 to 60 and -0.1~0.5 to 2.4 series |
1.5 |
1.5 |
5 |
|
Corrosion resistant type |
*YXC-100B-F *YXC-102B-F *YXC-103B-F *YXC-150B-F *YXC-152B-F |
0~0.16 to 60 and -0.1~0.06 to 2.4 series |
1.5 |
1.5 |
4 |
||
Corrosion resistant and vibration resistant type |
*YXC-100B-FZ *YXC-102B-FZ *YXC-152B-FZ *YXC-153B-FZ |
0~0.6 to 60 and -0.1~0.5 to 2.4 series |
1.5 |
1.5 |
5 |
||
Note: 1) Models marked with "*" are temporarily limited to special orders
2) The isolated soft tail length is 1, 2, 3, and 4m (with 2m being the preferred length)
Electrical parameters and control forms of contact devices
Contact power |
Zui High Operating Voltage |
Maximum working current |
Control form |
30VA (resistive load) |
220V D.C or 380V A.C |
1A |
Upper and lower limits, dual upper limits, dual lower limits |
Note: When the current is 1A, the operating voltage should be lower than 40V.
Environmental conditions for use
type |
Working temperature range |
relative humidity |
Anti working vibration performance |
|
medium |
surrounding environment |
|||
普通型、型 |
-40~70℃ |
not more than 85% |
V. Level H.3 |
|
Corrosion resistant type |
-25~55℃ |
Not exceeding 90% |
V. Level H.3 |
|
Anti vibration type, corrosion-resistant and anti vibration type |
V. H.4 level |
|||
Isolation type ordinary type |
Below 150 ℃ |
-40~70℃ |
V. Level H.3 |
|
Isolated corrosion-resistant type |
-40~70℃ |
|||
Isolation type other types |
Below 150 ℃ |
-25~55℃ |
V. H.4 level |
|
Temperature effect: The displayed value should not exceed 0.4%/10 ℃, and the set point should not exceed 0.6%/10 ℃ (with a deviation of 20 ± 5 ℃ from the operating temperature)