Overview
The shock resistant electric contact pressure gauge YTNXC-100 aviation plug cable joint is used to measure the positive and negative pressures of gas and liquid media that do not corrode copper and copper alloys. When the pressure reaches a predetermined value, a signal is sent to connect the control circuit and achieve the purpose of automatic control alarm.
Product Details

Seismic resistant electric contact pressure gauge YTNXC-100 aviation plug cable connectorIt consists of a measurement system, an indicator device, a magneto electric contact device, a housing, an adjustment device, and a junction box (plug socket). The working principle of the instrument is based on the spring tube in the measurement system, which is forced to produce corresponding elastic deformation displacement at the end of the spring tube under the pressure of the measured medium. With the help of the connecting rod and the transmission of the gear transmission mechanism, it is amplified and the measured value is gradually indicated on the dial by the indicator pointer (together with the contact) fixed on the gear shaft. At the same time, when it comes into contact with the contact point (upper or lower limit) on the set pointer (dynamic breaking or dynamic closing), it causes the circuit in the control system to be disconnected or connected, in order to achieve automatic control and send alarm signals.

Seismic resistant electric contact pressure gauge YTNXC-100 aviation plug cable connectorModel designation

Y

X

C

Specifications

content

Instrument category

pressure gauge

Control method

Slow moving contact position switch

Contact form of contact device

:

Magnetic assisted action type

A


Suitable for ammonia and its mixtures

G


Equipped with isolation device


-




ceremony

table

public

call, name, say, weigh

straight

path

and

type

formula


100 and 150 respectively represent radial formulas with diameters of 100 and 150mm


102 represents a diameter of 100mm towards the rear edge


103 and 153 respectively represent axial embedded types with diameters of 100 and 150mm

B




-




Other functions

F - Corrosion resistance; Z-anti vibration; FZ Corrosion and Vibration Resistance


Y

X

C

-

B

-



Main technical indicators and functions

Scale range, accuracy level, and joint thread size

type

model

name

Scale range MPa

Accuracy class

threaded joint
size

instruction

set value

connect

disconnect

普通型

YXC-100

*YXC-102

YXC-103

Magnetic assisted electric contact pressure gauge

0-0.6 to 60 and

-0.1-0.06 to 2.4 series

1.5

1.5

4

M20×1.5
(*G3/8)
(*G1/2')

YXC-150

*YXC-153

0-0.1 to 60 and

-0.1-0 to 2.4 series

type

YXCA-150

Magnetic assisted electric contact ammonia pressure gauge

0-0.16 to 60 and

-0.1-0.06 to 2.4 series

2.5

2.5

4

Anti vibration mode

YXC-100-Z

*YXC-102-Z

YXC-103-Z

Magnetic assisted electric contact pressure gauge

0~0.6 to 60 and -0.1~0.5 to 2.4 series

1.5

1.5

5

Corrosion resistant type

*YXC-100B-F

*YXC-102B-F

*YXC-103B-F

*YXC-150B-F

*YXC-152B-F

0~0.16 to 60 and -0.1~0.06 to 2.4 series

1.5

1.5

4

Corrosion resistant and vibration resistant type

*YXC-100B-FZ

*YXC-102B-FZ

*YXC-152B-FZ

*YXC-153B-FZ

0~0.6 to 60 and -0.1~0.5 to 2.4 series

1.5

1.5

5

Note: 1) Models marked with "*" are temporarily limited to special orders

2) The isolated soft tail length is 1, 2, 3, and 4m (with 2m being the preferred length)

Electrical parameters and control forms of contact devices

Contact power

Zui High Operating Voltage

Maximum working current

Control form

30VA (resistive load)

220V D.C or 380V A.C

1A

Upper and lower limits, dual upper limits, dual lower limits

Note: When the current is 1A, the operating voltage should be lower than 40V.

Environmental conditions for use

type

Working temperature range

relative humidity

Anti working vibration performance

medium

surrounding environment

普通型、型

-40~70℃

not more than 85%

V. Level H.3

Corrosion resistant type

-25~55℃

Not exceeding 90%

V. Level H.3

Anti vibration type, corrosion-resistant and anti vibration type

V. H.4 level

Isolation type ordinary type

Below 150 ℃

-40~70℃

V. Level H.3

Isolated corrosion-resistant type

-40~70℃

Isolation type other types

Below 150 ℃

-25~55℃

V. H.4 level

Temperature effect: The displayed value should not exceed 0.4%/10 ℃, and the set point should not exceed 0.6%/10 ℃ (with a deviation of 20 ± 5 ℃ from the operating temperature)