BUSCHJOST Baoshuo solenoid valve 8240600.9101.024.00
testing:
Connection testing system
Connect the inlet of the pressure testing equipment to the inlet of the solenoid valve through a connecting pipeline, ensuring a secure and well sealed connection to prevent fluid leakage during the testing process.
Connect the outlet of the solenoid valve to the inlet of the shut-off valve through a connecting pipeline. The outlet of the shut-off valve can be connected to a collection container or directly discharged to a safe area (determined according to the actual situation).
Close the relevant valves
Close the shut-off valve to ensure that the testing system is in a closed state, preventing the testing fluid from accidentally flowing out during the testing process.
Apply initial pressure
Start the pressure testing equipment and slowly apply pressure to the testing system to a certain proportion (such as 80%) of the normal working pressure of the solenoid valve. Observe the pressure changes to ensure that there are no abnormal leaks in the system causing rapid pressure drop. If the pressure drops too quickly, check if there are any leakage points at the connection points and repair them.
Stabilize the pressure and record it
Maintain stable applied pressure, record the pressure value P1 and time t1 at this time. The pressure stabilization time should be determined according to the type and working requirements of the solenoid valve, and can generally be set to 5-10 minutes to ensure that the system reaches a stable state.

Power on test:
Connect the power supply and apply rated voltage to the solenoid valve. Pay attention to the reverse and closing of the solenoid valve at the moment of power on. The working status of the solenoid valve can be determined by observing the flow of the medium, the opening indication of the valve, or related feedback signals.
Test different power on times and on-off frequencies to check the response speed and stability of the solenoid valve under different working conditions. For example, in situations such as short-term power on, long-term power on, and frequent power on/off, check for any abnormal sounds, sparks, or smoke. If these abnormalities occur, the power should be immediately cut off, the cause should be checked, and the fault should be eliminated before testing.
Observe the action of the solenoid valve after being powered on, whether it can be accurately opened according to the control signal, to ensure that the solenoid valve can work normally and will not malfunction due to overheating or other reasons.
BUSCHJOST Baoshuo solenoid valve 8240600.9101.024.00