FESTO Festo solenoid valve VSVA-B52-H-A1-1R5L

NegotiableUpdate on 03/31
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
FESTO Festo solenoid valve VSVA-B52-H-A1-1R5L $r $n medium temperature $r $n-5 #176; C ... 50 #176; C $r $n Relative air humidity $r $n0-90% r $n Protection for direct and indirect contact $r $nPELV $r $n Pilot medium $r $n Compressed air, in accordance with ISO 8573-1:2010 [7:4:4] $r $n Environmental temperature $r $n-5 #176; C ... 50 #176; C $r $n Maximum tightening torque for valve installation $r $n1.8 Nm... 2.2 Nm $r $n Product weight $r $n270 g
Product Details

FESTO Festo solenoid valve VSVA-B52-H-A1-1R5L

Fault analysis:

Fault phenomenon

After power on, the valve core reversing is delayed, and the action of the executing components is slow;

There is a noticeable abnormal noise when reversing, accompanied by valve body vibration.

Processing Steps

Check lubrication condition: Some of the solenoid valves in the Noron require air source lubrication (oil mist supply). Insufficient lubrication can increase the friction force of the valve core. Adjust the oil mist drip rate to 1-2 drops per minute and use specialized pneumatic lubricating oil.

Check for impurities in the air source: Moisture and oil stains in compressed air can exacerbate valve core wear. Regular drainage and replacement of filter cartridges are necessary to ensure a clean and dry air source.

Check the installation status of the valve body: If the valve body is not installed firmly or the installation surface is uneven, it will cause uneven force on the valve core. Re tighten the installation bolts and correct the installation plane.

FESTO费斯托电磁阀VSVA-B-B52-H-A1-1R5L

Features:

Advantages of Direct Acting Design

Zero pressure start: It can reliably operate even under zero pressure difference or vacuum environment, while pilot operated valves cannot work

Quick response: direct drive without delay, suitable for fast control scenarios

Simple structure: no complex pilot circuit, reducing fault points, easy maintenance

2. Safety features

Fault safety mechanism: automatically returns to a safe position when power is cut off, in compliance with industrial safety standards

Dynamic self-monitoring: can integrate sensors to monitor valve status and prevent malfunctions

No residual pressure: ensuring maintenance safety and avoiding accidental start-up

3. Material and sealing system

Multiple material options: Suitable for different media and environments (such as corrosive liquids, high-temperature gases)

Double sealed structure: improves reliability, extends service life, and reduces leakage risk

Long life design: capable of over 2 million working cycles, reducing maintenance frequency


FESTO Festo solenoid valve VSVA-B52-H-A1-1R5L