Phone
13261731718
-
Address
Mingliu Future Building, Majiabao West Road, Fengtai District, Beijing
Beijing Huayi Tongtai Environmental Protection Technology Co., Ltd
13261731718
Mingliu Future Building, Majiabao West Road, Fengtai District, Beijing
The Beijing Huayun GXH-3010/3011BF portable infrared CO/CO2 two in one analyzer has a built-in zero adjustment filter and a six way valve to switch between zero adjustment and measurement. It can display mg/m3 and add a one click automatic zero adjustment function.
Beijing Huayun GXH-3010/3011BF Portable Infrared CO/CO2 2-in-1 Analyzer Product Introduction:
This instrument complies with the national standards of GB/T18204.2-2014 "Methods for hygiene inspection in public places - Part 2: Chemical pollutants", GBZ/T300.37-2017 "Determination of toxic substances in workplace air - Part 37: Carbon monoxide and carbon dioxide", and GB/T9801-1988 "Determination of carbon monoxide in air quality - Non dispersive infrared method".
This instrument complies with the national metrological verification regulations of JJG635-2011 "Infrared Gas Analyzer for Carbon Monoxide and Carbon Dioxide", and its main technical indicators meet the technical requirements of national secondary instruments. It can obtain a verification certificate from the Chinese Academy of Metrology (verification conclusion: qualified, this instrument meets the secondary technical requirements).
This instrument has a built-in zero adjustment filter and a six way valve for switching between zero adjustment and measurement, making it easy and flexible to operate.
This instrument can display mg/m3; Measurement range can be customized.
This instrument can add a one click automatic zeroing function.
The main technical specifications of Beijing Huayun GXH-3010/3011BF portable infrared CO/CO2 two in one analyzer are:
Measurement principle: Non dispersive infrared analysis method/Non dispersive infrared method (NDIR)
Sampling method: built-in pump suction
Measurement range: 0~50.0 × 10-6CO, 0~0.500% CO2 or 0~200.0 × 10-6CO, 0~1.000% CO2
Resolution: 0.1 × 10-6 CO; 0.001% CO2
Repeatability: ≤ 1% full scale
Zero drift: ≤± 2% at full scale/h
Span drift: ≤± 2% full scale/3h
Linear deviation: ≤± 2% at full scale
Temperature additional error: (between 10 ℃ and 45 ℃) ≤± 2% at full scale/10 ℃
Carbon monoxide interference: 1250mg/m3CO ≤± 0.3% at full scale
Preheating time: ≤ 30 minutes
Response time: CO: t0~t90 ≤ 45S; CO2:t0~t90≤15S
Flow range: (0.5-1.2) L/min
Storage function: ≤ 5000 sets of measurement data
Digital interface: USB, equipped with data transfer software
Standard configuration: host, sampler, battery, charger, USB flash drive, connecting cable, technical documents, portable case
Power supply: AC/DC dual-use, 220AVC (± 10%) or built-in rechargeable battery
Dimensions: 270 × 230 × 90 (mm)
Weight: ≤ 3.5kg