Product Introduction of UK Kane KNAEKM905 Smoke Analyzer:
KANE KM 905 smoke analyzer from the UK, KM905 replaces KM940, updates processor, and adds Bluetooth transmission function option. Product Introduction: The KM905 flue gas analyzer is used for combustion testing and monitoring of flue gas pollution emissions in boilers. The KM905 flue gas analyzer is compact in size and easy to operate.
UK Kane KNAEProduct features of KM905 flue gas analyzer:
·Large LCD display screen, convenient for viewing measurement results
·Equipped with dual probes with strong adsorption capability
·Added new sensors capable of detecting three types of gases and increased sensor accuracy
·The probe tube is lined with polytetrafluoroethylene to reduce gas absorption from any sample
·The KANE905 can remember and store 150 readings, and is a printer or PC capable of transmitting data
·Can be connected to the printer using infrared radiation Printing files can be customized
·Personalized information storage date, each measurement, and management of information such as company name
·Equipped with a long-life battery charging device
KM905 is an instrument used for measuring and analyzing flue gas from industrial boilers
Suitable for all industrial boilers, it can simultaneously display 8 parameters on the display screen and calculate boiler efficiency and pollution level
·KM905 can measure oxygen, flue temperature, and calculated values of CO2, boiler efficiency, excess air, and losses
·We will also customize relevant sensors according to customer requirements
Measurable
·Oxygen, carbon monoxide, nitric oxide, nitrogen dioxide, sulfur dioxide, inlet temperature, flue gas temperature, pressure difference can be calculated
·Smoke efficiency, carbon dioxide content, loss, excess air, CO/CO2 ratio, toxicity index, net temperature difference
UK Kane KNAETechnical parameters of KM905 flue gas analyzer:
parameter |
resolution |
accuracy |
range |
describe |
temperature measurement | ||||
Flue temperature |
1.0℃/F |
±2.0℃ ±0.3reading |
0-600℃ 32-1112°F |
|
ambient temperature |
0.1℃/F |
±1℃ ±0.3%reading |
0-50℃ 32-122°F |
|
pressure |
0.1 mbar |
±2% of full scale |
+150mbar to 150mbar |
|
Gas measurement | ||||
oxygen |
0.1% |
±0.2% |
0-21% |
|
CO |
1ppm |
±20ppm <400ppm |
0-10,000ppm |
Replaceable sensor |
NO2 |
1ppm |
± 5% reading |
0-5,000ppm |
Replaceable sensor |
CO2 |
1ppm |
± 5% reading |
0-1,000ppm |
Calculated value |
SO2 |
1ppm |
± 5% reading |
0-5,000ppm |
Replaceable sensor |
response time |
Response time<3S |
|||
Automatic calculation | ||||
NOx |
1ppm |
± 5% reading |
0-99.9% |
|
CO2 |
0.1% |
± 0.3% reading |
0-99.9% |
|
loss |
0.1% |
± 1% reading |
0-99.9% |
|
Excess air coefficient |
0.1% |
±1% |
0-288.5% |
|
Net temperature |
0.1% |
± 0.2% reading |
-50-1200℃ |
|
CO/CO2 ratio |
0.0001 |
±0.0001 |
0-0.9999 |
|
PI |
0.1% |
±0.01 |
0-99.99 |
|
Standard configuration:
Built in fuel gauge |
Natural gas, coal gas, light oil, propane, butane, anthracite, coke, hard carbon |
size |
220mm × 55mm × 120mm |
power supply |
Input 110VAC/220VAC |
Built-in rechargeable battery |
Working continuously for 8 hours after charging |
Standard configuration |
Host, standard probe, rechargeable battery, portable bag, operation manual |
option |
KMCLP20,1m smoke anti adsorption probe, pre installed smoke filter |