Minneapolis blast doors have always been considered as one of the design building air tightness testing systems. Used by TEC (The Energy Conservation) HVAC system contractors, builders, and building thermal professionals in the United States. The company has developed a comprehensive testing program and integrated specialized testing accessories. This system can be used by demand side management (DSM) departments, energy consumption assessment, and blast door systems to test the airtightness level of building envelope structures, diagnose and demonstrate air infiltration issues, estimate natural air infiltration rates, and evaluate the energy efficiency generated by air infiltration

Product Details

Product Introduction:
Minneapolis blast doors have always been considered as a designed building air tightness testing system. Used by HVAC system contractors, construction industry professionals, and building thermal engineering professionals at TEC (The Energy Conservatory) in the United States. The company has developed a comprehensive testing program and integrated specialized testing accessories. This system can be used by demand side management (DSM) departments, energy consumption assessment, and blast door systems to test the airtightness level of building envelope structures, diagnose and demonstrate air infiltration issues, estimate natural air permeability and energy efficiency losses caused by air infiltration, and can be used to evaluate the overall performance of buildings.
Configure window testing accessories to test the air tightness of doors and windows.
Features:
Precision designed and rigorously calibrated fans
Lightweight fan casing treated with injection molding and roughening
Accurate and stable flow measurement without the need to replace the flow meter
A flow range that can be quickly and accurately measured, using a C-ring option, with a low flow limit of up to 100CFM
Solid state variable speed fan control
Compatible with pressure and pressure tests
Supports 110V or 220V AC power supply
Lightweight and durable door frame bracket
The revolutionary design of the variable aluminum frame and durable nylon cover has been developed through years of research and thousands of experiments.
There is no easier way than with this system to seal the blower fan inside the door opening
The full lock design ensures that the aluminum frame can be removed from the compact storage box and installed in just a few seconds
The precision designed cam rod device ensures a tight and seamless connection between the nylon cover and the door frame
Can adapt to various door frame sizes in common residential buildings (special door frames can also be customized)
Nylon cover with observation window for easy monitoring of outdoor activities

Standard configuration:
1. Fan with variable speed controller;
2.5 extendable door frame components and storage box
3. Nylon canvas cover with observation window; 4. Five flow control loops (A, B, C, D, E loops);
5. A tool kit with a protective pad that can store flow meters, user manuals, hoses, speed controllers, canvas covers, as well as laptops and other files;
DG-700 pressure and flow meter: includes two precision pressure sensors, which can simultaneously display indoor and outdoor pressure and the reading of the blower door fan. The specially designed "reference pressure" and "CFM @ 50" functions facilitate quick and accurate acquisition of airtightness data. In addition, DG-700 can also be connected to a laptop to achieve automatic measurement of the air duct through TECTITE software.
7. Air tightness testing and analysis software TECTITE (supporting Windows operating system):
The computable results of building airtightness tests include gap area, air exchange rate ACH50 under a pressure difference of 50pa, CFMSO, and building gap curve, and can predict natural and designed air infiltration rates as well as the resulting energy efficiency losses. The software interface is extremely user-friendly and has powerful online help functions. Fully compatible with manual testing using DG-700 flowmeter and automatic testing using APT system. Calculation program and test report that comply with CGSB-149.10-M86 standard. An easy-to-use data input module that can store and restore test parameter files. The generated test report format includes easy to understand summary tables and detailed technical reports.
8. Accessories for door and window airtightness testing: pipeline and adapter fittings
Optional accessories:
TEC WiFi connection
TEC WiFi link can connect to any DG-500 DG-700 or create a wireless network that can utilize any computer or mobile device compatible with WiFi functionality. By using our free WiFi connection software, you can monitor and control your instruments from anywhere in the room. Our WiFiLink will support the PC version of TECITE and TECLOG, as well as the iTEC-700 multifunctional application that supports Apple mobile devices (an Android application will be officially released in the spring of 2014). TECTITE and TECLOG users can now free their laptops from cable connections, allowing them to operate and test air vents anywhere inside the house without the need for cables. The iTEC-700 application allows you to remotely inspect the drum damper or Duck Blaster ® The system monitors the pressure in the combustion equipment area and operates the fan on and off.

component

project

parameter

Model 3 Drum Air Door

High traffic:

6300 CFM (2973 l/s, 10700 m3/h) (natural state)

5350 CFM (2524 l/s, 9090 m3/h) (pressure difference 50 Pa)

5000 CFM (2360 l/s, 8495 m3/h) (pressure difference of 75 Pa)

Small traffic:

300 CFM (141 l/s, 510 m3/h) (using B-ring)

85 CFM (40 l/s, 144 m3/h) (using C-ring)

30 CFM (14 l/s, 51 m3/h) (using D-ring)

11 CFM (5 l/s, 18 m3/h) (using E-ring)

Size:

Pipe diameter 50 cm, length 26 cm

Weight:

15 kg (including A and B rings)

Accuracy:

± 3% (using DG-700 pressure flow meter or APT system)

Calibration:

comply with ASTME779-03、E1554-07、CGSB-149.10-M86、EN 13829、ATTMA Technical Standard 1 and NFPA 2001 standard

voltage

110V or 220V

Adjustable door frame and materials

Door frame material:

Molded aluminum material

Width:

71~101 cm

height

132~244 cm

Sealing material:

EPDM rubber (including dicyclopentadiene) flexible cushion layer

Cover material: