Bus coupler IL PB BK DI8 DO4/EF-PAC

NegotiableUpdate on 03/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Bus coupler IL PB BK DI8 DO4/EF-PAC $r $nINLine, bus coupler, PROFIBUS DP, D-SUB-9 female connector, digital input: 8,24 V DC, connection technology: 3 wires, digital output: 4,24 V DC, 500 mA, connection technology: 3 wires, local bus transmission rate: 500 kBit/s/2 MBit/s, protection level: IP20, including Inline connector and marking strip
Product Details

Bus coupler IL PB BK DI8 DO4/EF-PAC
IL PB BK DI8 DO4/EF-PAC
-bus coupler
2692322

Inline, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, digital input: 8, 24 V DC, connection technology: 3 wires, digital output: 4, 24 V DC, 500 mA, connection technology: 3 wires, local bus transmission rate: 500 kBit/s/2 MBit/s, protection level: IP20, including Inline connector and marking strip

总线耦合器IL PB BK DI8 DO4/EF-PAC总线耦合器IL PB BK DI8 DO4/EF-PAC总线耦合器IL PB BK DI8 DO4/EF-PAC

Bus coupler IL PB BK DI8 DO4/EF-PAC
Product Details


The bus coupler with built-in I/O is specifically designed for PROFIBUS networks and can be connected to Inline I/O systems. This bus coupler can connect up to 61 Inline devices. Provide supporting GSD files for integrating the Inline site into the programming system.



Size chart
width 80 mm
height 119.8 mm
depth 71.5 mm
Notes on Dimensional Data Pin connector specifications

Usage restrictions
CCCex Explanation It is not allowed to be used in potential explosive areas in China.

PROFIBUS DP
number of interfaces 1
connection method D-SUB-9 female connector
transmission speed 9,6 kBit/s . .. 12 MBit/s
Inline local bus
connection method Inline data bridging block
transmission speed 500 kBit/s/2 MBit/s (automatic detection, no system combination)

System limitations
Number of supported devices 63 (per station)
The number of devices that can be connected to the local bus 61 (onboard I/O consists of two devices)
Number of devices with parameter channels 16
Number of branch terminals supported with remote bus branches 0
I/O response time Typical value of 4 ms (parallel I/O; Transmission speed PROFIBUS 1.5 Mbps, local bus 500 kbps)
module
Hexadecimal ID encoding 0B50
Enter address area 8-bit (or 1-byte, select from GSD file)
Output address area 4 bits (or 1 byte, select from GSD file)
Register length 16 bits

Numerical quantity:
input name digital input
Input instructions EN 61131-2 Type 1
Input quantity 8
connection method Inline connector
connection system 3 lines
input voltage 24 V DC
Input voltage range, '0' signal -30 V DC . .. 5 V DC
Input voltage range, '1' signal 15 V DC . .. 30 V DC
Rated input voltage UIN 24 V DC
Rated input current UIN Typical value 3 mA
Typical input current for each channel Typical value 3 mA
Typical response time Approximately 500 µ s
Signal switching delay time from 0 to 1 2.9 ms
1 to 0 signal switching delay time 2.9 ms

Numerical quantity:
Output Name digital output
connection method Inline connector
connection system 3 lines
Output quantity 4
protection circuit Short circuit and overload protection; Output driver freewheeling circuit
output voltage 24 V DC -1 V (at rated current)
Output current of each module 2 A
Rated output voltage 24 V DC
Output current when disconnected 10 µ A (voltage can be measured without load even if no output is set). )
Rated load, inductive 12 VA (1.2 H,48 Ω)
Rated load, indicator light 12 W
Rated load, resistive 12 W
Reverse voltage resistant to short pulses Prevent reverse voltage
Overload behavior Auto-restart
Inductive overload action Output may be damaged
Behavior when voltage is turned off No delay between output and power supply
Signal delay Typical value 2.9 ms
Overcurrent shutdown Minimum 0.7 A

Product Type I/O components
Product Series Inline
type module
Scope of supply Including Inline connectors and marker strips
Number of channels 12
Diagnostic information Digital output short circuit or overload is
What is the sensor power failure
What is the power failure of the actuator
Insulation characteristics
Overvoltage category II (IEC 60664-1,EN 60664-1)
pollution level 2 (IEC 60664-1,EN 60664-1)

Power consumption under rated conditions 23.5 VA
electric potential
power consumption Typical value 1.7 W (for the entire device)
Potential: Bus coupler power supply UBKCommunication power supply UL(7.5 V) and analog power supply UANA(24V) Powered by a bus coupler power supply.
power supply voltage 24 V DC (via Inline connector)
Power supply voltage range 19.2 V DC... 30 V DC (including all tolerances, including ripple)
current consumption 0.98 A (connected number of I/O modules)
Minimum 80 mA (without connected I/O module)
Potential: Communication power supply (U)L)
power supply voltage 7.5 V DC
Potential: power supply for analog module (U)ANA)
power supply voltage 24 V DC
Power supply voltage range 19.2 V DC... 30 V DC (including all tolerances, including ripple)
Potential: Main circuit (U)M)Power supply
power supply voltage 24 V DC (via Inline connector)
Power supply voltage range 19.2 V DC... 30 V DC (including all tolerances, including ripple)
current consumption 8 A DC
Minimum 3 mA (not connected to peripheral devices)
Potential: segmented circuit power supply (US)
power supply voltage 24 V DC (via Inline connector)
Power supply voltage range 19.2 V DC... 30 V DC (including all tolerances, including ripple)
current consumption 8 A DC
Minimum 3 mA (not connected to peripheral devices)
Electrical isolation/voltage range isolation
Test voltage resistance: PROFIBUS interface/communication power supply (U)BK、UL、UANA) 500 V AC, 50 Hz, 1 min.
Test voltage resistance: PROFIBUS interface/I/O (U)M、US) 500 V AC, 50 Hz, 1 min.
Test voltage resistance: PROFIBUS interface/functional grounding 500 V AC, 50 Hz, 1 min.
Test voltage resistance: Communication power supply (U)BK、UL、UANA)/I/O (UM、US) 500 V AC, 50 Hz, 1 min.
Test voltage resistance: Communication power supply (U)BK、UL、UANA)/Functional grounding 500 V AC, 50 Hz, 1 min.
Test voltage resistance: I/O (U)M、US)/Functional grounding 500 V AC, 50 Hz, 1 min.

Connection technology
Connection Name Inline connector
Wire connection
connection method Pull back spring connection
Rigid wire cross-section 0.08 mm² . .. 1.5 mm²
Cross section of flexible wire 0.08 mm² . .. 1.5 mm²
Connectable guide cross-section AWG 28 . .. 16
Stripping length 8 mm
Inline connector
connection method Pull back spring connection
Cross section of hard wire 0.08 mm² . .. 1.5 mm²
Cross section of flexible wire 0.08 mm² . .. 1.5 mm²
Connectable guide cross-section AWG 28 . .. 16
Stripping length 8 mm

environmental conditions
Environmental temperature (operating) -25 °C . .. 60 °C
protection level IP20
Air pressure (operation) 70 kPa... 106 kPa (up to an altitude of 3000 meters)
Air pressure (storage/transportation) 70 kPa... 106 kPa (up to an altitude of 3000 meters)
Environmental temperature (storage/transportation) -25 °C . .. 85 °C
Allow humidity (operation) 10 % . 95% (no condensation)
Allow humidity (storage/transportation) 10 % . 95% (no condensation)

protection level III (IEC 61140,EN 61140,VDE 0140-1)

Installation Type DIN rail installation

Order Number 2692322
packaging unit 1 pc
Minimum order quantity 1 pc
Sales key code DRI112
Product key code DRI112
Catalog page Page 109 (C-6-2019)
GTIN 4046356315272
Individual weight (including packaging) 325.3 g
Individual weight (excluding packaging) 343.2 g
Tariff number 8538900000
place of origin DE





Compatible products



advantage

PROFIBUS connection is achieved through a 9-bit D-SUB socket
Electrical isolation between PROFIBUS interface and logic
8 digital inputs, 4 digital outputs (onboard)
Can connect up to 16 PCP devices
DP/V1 for level 1 and level 2 hosts
PROFIBUS data transmission speed ranges from 9.6 kbps to 12 Mbps
Rotary encoding switch for setting PROFIBUS address
Supports PROFIBUS addresses from 0 to 126
I&M function
IO Link call (firmware 2.0 and above)
Operation of PROFIsafe equipment