CQ stainless steel magnetic pump manufacturer shipsworking principle
The electric motor drives the outer magnetic steel rotor to rotate, and through the action of the magnetic field, drives the inner magnetic steel rotor connected to the impeller to rotate synchronously, achieving contactless power transmission. The liquid is enclosed in a stationary isolation sleeve, forming a fully sealed structure. The internal and external magnetic steel are driven by magnetic coupling, eliminating the friction and leakage risks of mechanical seals. At the same time, when overloaded, the internal and external magnetic steel automatically slip off, protecting equipment safety.
CQ stainless steel magnetic pump manufacturer shipsProduct function
Core conveying function: By driving the impeller to rotate through a magnetic field, continuous conveying of corrosive or hazardous liquids can be achieved.
Security guarantee: The fully sealed structure prevents the leakage of toxic and flammable media, protecting the safety of operators and the environment.
Process support: Ensure stable medium circulation and improve product quality in chemical production, electroplating processes, or pharmaceutical processes.
Environmental compliance: Meet the leak free requirements of environmental regulations for industrial wastewater and waste liquid treatment.
Precautions for use:
During the installation process, the pipeline should be installed strictly according to the inlet and outlet directions of the CQ magnetic pump to prevent problems such as unstable pump speed caused by reverse installation.
During use, the sealing of each component of the pump body should be regularly checked, and the seals should be replaced and maintained regularly.
The temperature range for use is generally -20 ℃~100 ℃, avoid using beyond this range.
During operation, attention should be paid to preventing foreign objects from entering the pump body. If foreign objects are found, they should be cleaned up in a timely manner.
Magnetic pumps should be installed horizontally and not vertically, and plastic pump bodies should not bear the weight of pipelines.
If the conveyed medium contains solid particles, a filter screen should be added to the pump inlet; If it contains ferromagnetic particles, a magnetic filter should be added.
After 500 hours of operation of the magnetic pump, the wear of the bearings and end face moving rings should be disassembled and inspected to ensure their normal operation.