Circulating water pump ISG single-stage clean water pump manufacturer pipeline pump

NegotiableUpdate on 04/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
ISG single-stage single suction vertical pipeline centrifugal pump circulating water pump ISG single-stage clear water pump manufacturer, circulating water pump ISG single-stage clear water pump manufacturer pipeline pump vertical pump based on clever combination design. At the same time, suitable hot water, high temperature, and corrosive chemical pumps and oil pumps are dispatched based on the ISG type according to different operating temperatures, media, etc. This series of products has the advantages of high efficiency, energy saving, low noise, and reliable performance.
Product Details

Circulating water pump ISG single-stage clean water pump manufacturer pipeline pump


1ISG single-stage clean water pump manufacturer for circulating water pumpProduct Overview:

The ISG single-stage single suction vertical pipeline centrifugal pump is designed by Shanghai Bangpu Pump Industry Manufacturing Co., Ltd. and domestic water pump experts using an excellent hydraulic model, adopting the performance parameters of the IS centrifugal pump, and cleverly combining them on the basis of a general vertical pump. At the same time, suitable hot water, high temperature, and corrosive chemical pumps and oil pumps are dispatched based on the ISG type according to different operating temperatures, media, etc. This series of products has the advantages of high efficiency, energy saving, low noise, and reliable performance.


IIISG single-stage clean water pump manufacturer for circulating water pumpFeatures:

1. The pump is a vertical structure with the same inlet and outlet diameters and located on a unified centerline. It can be installed in pipelines like a valve, with a compact and beautiful appearance, small footprint, and low construction investment. If a protective cover is added, it can be used outdoors.

2. The impeller is directly mounted on the extended shaft of the motor, with a short axial dimension and compact structure. The pump and motor bearings are reasonably configured, which can effectively balance the radial and axial loads generated by the pump operation, ensuring smooth pump operation and low vibration noise.

3. The shaft seal adopts mechanical seal or a combination of mechanical seals, using imported titanium alloy sealing rings, medium-sized high-temperature resistant mechanical seals, and hard alloy materials for wear-resistant seals, which can effectively increase the service life of mechanical seals.

4. Easy installation and maintenance, no need to disassemble the piping system, just remove the pump coupling nut to extract all rotor components.

5. Pumps can be operated in series or parallel according to the requirements of flow rate and head.

6. Vertical and horizontal installation of pumps can be adopted according to the requirements of pipeline layout.





IIIReasons for fixing obstacles and troubleshooting methods:

Pipeline pump malfunction phenomenon

Possible history of pipeline pumps

Troubleshooting methods for pipeline pumps

The pipeline pump is not producing water

The inlet and outlet valves of the pipeline pump are not open, the inlet and outlet pipelines are blocked, and the flow impeller is blocked

Check and remove blockages

The direction of operation of the pipeline pump motor is incorrect, and the motor has a slow speed due to phase loss

Adjust the motor direction and strengthen the motor wiring

Pipeline pump suction pipe leakage

Tighten all sealing surfaces and eliminate air

The pipeline pump is not filled with liquid and there is air in the pump chamber

Open the pump cover or open the exhaust valve to exhaust all the air

Insufficient water supply at the inlet and outlet of the pipeline pump, high suction stroke, and leakage of the bottom valve

Shutdown inspection and adjustment (this phenomenon is prone to occur when using grid connected water pipes and suction pumps).

The pipeline resistance of the pipeline pump is too high, and the pump selection is improper

Reduce pipeline bends and reselect pumps

Insufficient flow of pipeline pump

First, check the reason according to 1

First, press 1. Exclude

Pipeline pump pipeline, pump passage impeller partially blocked, scale deposition, insufficient valve opening

Remove the obstruction and readjust the valve opening

Low voltage of pipeline pump

voltage stabilization

Wear of pipeline pump impeller

Replace the impeller

Excessive current in pipeline pump

Pipeline pump used at rated flow rate

Adjust the flow rate and turn down the outlet valve

The suction stroke of the pipeline pump is too high

Reduce suction distance

Wear of pipeline pump bearings

replace the bearing

Pipeline pump noise and vibration

Unstable support of pipeline pump pipeline

Stable pipeline

Pipeline pump liquid mixed with gas

Increase suction pressure and exhaust

Pipeline pump generates cavitation

降低真空度

Damaged pipeline pump bearings

replace the bearing

Pipeline pump motor running under heat load

Adjust according to 5

Pipeline pump motor overheating

The flow rate of the pipeline pump is too high and it is running under load

Turn down the outlet valve

Pipeline pump rubbing

Check and exclude

The bearing of the pipeline pump motor is damaged

replace the bearing

Insufficient voltage of pipeline pump

voltage stabilization

Pipeline pump leakage

Mechanical seal wear of pipeline pump

replace

The pipeline pump body has sand holes or cracks

Welding repair or replacement

The sealing surface of the pipeline pump is uneven

trim

Loose installation bolts of pipeline pump

fasten


4、 Installation instructions for pipeline booster pump:

1. Before installation, it is necessary to check whether the fasteners of the unit are loose, and whether the flow channel of the pump body is abnormal or blocked, in order to prevent damage to the impeller and pump body during the operation of the water pump.

2. The weight of the pipeline should not be added to the water pump during installation to avoid deformation of the pump.

3. The foundation bolts must be tightened during installation to avoid the impact of vibration on pump performance during start-up.

4. For the convenience of maintenance and safety of use, a regulating valve is installed on each inlet and outlet pipeline of the pump, and a pressure gauge is installed on the pump outlet accessory to ensure that it operates within the rated head and flow range, ensuring the normal operation of the pump and increasing its service life.

5. After installation, pull out the pump shaft. The impeller should have no friction sound or jamming phenomenon, and the pump should be disassembled to check the cause.

6. There are two types of pump installation: rigid connection installation and flexible connection installation (see connection method).


5、 ISG vertical pipeline pumpWorking conditions:

1. The suction pressure is ≤ 1.0MPa, or the maximum working pressure of the pump system is ≤ 1.6MPa, that is, the pump suction inlet pressure+pump head is ≤ 1.6MPa. The static pressure test pressure of the pump is 2.5MPa. Please specify the system working pressure when ordering. When the working pressure of the pump system is greater than 1.6MPa, it should be separately stated when ordering, so that the overcurrent and connection parts of the pump can be made of cast steel materials during manufacturing.
2. Environmental temperature<40 ℃, relative humidity<95%.
3. The volume content of solid particles in the conveyed medium is less than 0.1% of the unit volume, and the particle size is less than 0.2mm.

Note: If the medium used is with small particles, please specify when ordering so that the manufacturer can use wear-resistant mechanical seals.