Welcome Customer !

Membership

Help

Anhui Huaqiang Cable Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Compensation wire \ KX-HS \ FB \ 5 * 2 * 1.5

NegotiableUpdate on 05/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Compensation wire \\ KX-HS \\ FB \\ 5 * 2 * 1.5 PTFE insulation, glass fiber braided sheath, heat-resistant precision grade K index thermocouple high-temperature compensation wire; Connect them to thermocouples and measuring devices to compensate for the errors caused by temperature changes at the connection between them and thermocouples. It is divided into two types: extension type and compensation type.

Product Details

The technical parameters and application characteristics of the compensation wire model KX-HS-FB 5 × 2 × 1.5mm ² are as follows:

1Compensation wire \ \ KX-HS \ \ FB \ \ 5 * 2 * 1.5Model Analysis

  1. KX: Suitable for K-scale thermocouple (nickel chromium nickel silicon alloy).

  2. HS: Heat resistant, precision grade (old standard is represented by 'A').

  3. ‌FB‌:

    • F: Fluoroplastic insulation (positive electrode red, negative electrode black);

    • B: Glass fiber woven sheath (temperature resistance up to 450 ℃).

  4. ‌5 ×2×1.5mm² ‌:

    • 5 pairs of dual core cables;

    • Each conductor has a cross-sectional area of 1.5mm ².

补偿导线\\KX-HS\\FB\\5*2*1.5

IICompensation wire \ \ KX-HS \ \ FB \ \ 5 * 2 * 1.5Core parameters

Project Specifications
Conductor material Positive electrode: nickel chromium alloy; Negative electrode: nickel silicon alloy
insulation resistance ≥100 MΩ·km(20℃)
Reciprocating resistor (20 ℃) ≤ 0.73 Ω/m (1.5mm ² single core)
Thermoelectric potential tolerance Precision grade ± 1.5 ℃ (8137 μ V ± 60 μ V)
pressure rating 1000V/1min14
Long term working temperature -60 ℃~450 ℃ (glass fiber sheath) 36

IIICompensation wire \ \ KX-HS \ \ FB \ \ 5 * 2 * 1.5special design

  • Shielding and Armoring:

    • Standard model without shielding layer;

    • When shielding or armor is required, additional identification should be added to the suffix (such as' P2 'for copper tape shielding and' 22 'for steel tape armor).

  • Flame retardant type: prefixed with ZR -, in compliance with GB/T18380 A/B/C flame retardant standards.

  • Soft core conductor: For multi strand soft cores, 'R' (such as KX-HS-FBR) should be added after the model number.

4Compensation wire \ \ KX-HS \ \ FB \ \ 5 * 2 * 1.5Application scenarios

  • Suitable for high temperature and highly corrosive environments (such as metallurgy, petrochemicals, and electricity);

  • Ensure that the positive and negative connections are correct (positive red line, negative black line);

  • Bending radius ≥ 10 times the outer diameter of the cable.

  • Note: Glass fiber braided sheath (FB) has significantly better temperature resistance than fluoroplastic sheath (FF/FP), but has lower flexibility and is suitable for fixed installation scenarios.