Welcome Customer !

Membership

Help

Changzhou Peide Water Treatment Equipment Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Changzhou Peide Water Treatment Equipment Co., Ltd

  • E-mail

    wuzq1970@126.com

  • Phone

    18915011981

  • Address

    206 Qingyang North Road, Tianning District, Changzhou City

Contact Now

Constant pressure water replenishment device pressure tank

NegotiableUpdate on 01/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Nowadays, we are paying more and more attention to environmental protection, and relevant regulations are becoming increasingly strict. Many industries need to equip corresponding equipment to make their workshop circulating water systems energy-saving. Some companies use constant pressure water replenishment devices and pressure tanks. So, let's introduce the precautions during its operation.
Product Details

Nowadays, we are paying more and more attention to environmental protection, and the relevant regulations are becoming increasingly strict. Many industries need to equip corresponding equipment to make their workshop circulating water system energy-saving. Some companies will use itConstant pressure water replenishment device pressure tankSo let's introduce the precautions during its operation.

图片4

(1) This oneConstant pressure water replenishment device pressure tankCan be placed in the basement thermal room or foundation interlayer. Due to the small diameter piping of the equipment being prone to freezing damage, outdoor installation should be avoided as it may affect normal operation.
(2) The power supply requires stability and reliability, otherwise technical measures should be taken.
(3) The weighing sensor is placed under one leg of the atmospheric pressure tank. Note that the tank leg should slowly fall down and press on the weighing sensor, and the weighing sensor should not be impacted, otherwise it will be damaged.
(4) Both the exhaust pipe and the expansion pipe should be connected to the return water main pipe on the suction side of the circulating pump. According to the direction of water flow, the exhaust pipe should be connected at a distance of 2 meters before the expansion pipe. That is, the return water should first flow through the exhaust pipe joint and then through the expansion pipe joint (constant pressure point).
(5) The connection of the water replenishment pipe only requires a pressure of 0.1MPa. If the water replenishment pressure cannot meet this requirement, other technical measures should be taken.
(6) In order to prevent a large amount of dirt from directly entering the equipment, the connecting pipeline should be connected from the top, and filters should be installed in front of the water source electric valve and the pressure relief electric valve.
The outlet of the atmospheric pressure tank must be higher than the inlet height of the water pump, generally greater than 30mm. Otherwise, gas in the water will accumulate in the inlet pipeline of the water pump, affecting the water pump's suction.
(9) The weight of the water pump outlet pipeline cannot be pressed on the water pump, which will affect the normal operation of the water pump and valves.
(10) Before connecting the pipeline to the electric valve, manual valves must be installed. In case of shutdown or sudden power outage, to prevent the system water from draining, please close all manual valves first and open them after the power is restored.