Peide Broad Spectrum Induction Water ProcessorRemoving dirt and killing in water treatment Bacteria play an extremely important role in the issue. However, it cannot be ignored that in the use process of many factories and enterprises, the broad-spectrum induction water processor will only be taken seriously if there are problems, which has caused a lot of unnecessary losses and waste.
Peide Water Treatment, a water treatment manufacturer, will explain two common maintenance measures for broad-spectrum induction water processors to prevent problems before they occur.
1. Stable performance: Digital frequency conversion technology provides higher stability and stronger anti-interference ability;
2. Intelligent sensing: It can automatically adjust the output power and frequency according to the characteristics of different pipes, flow rates, media, etc;
3. Easy installation: simply wrap the coil around the outer wall of the pipeline, without the need to cut open the pipeline or drill holes on the equipment;
4. The host is installed in a ventilated area and equipped with a 220VAC 50HZ power supply nearby.

6. The surface of the pipeline to be installed should be clean, flat, smooth, and free of coverings, insulation layers, etc. The wrapped part of the pipeline must be a straight pipe.
7. It should be kept as far away as possible (2 meters away) from high-power electrical equipment to prevent composite full frequency signals from being affected by magnetic field interference.
8. Determine the installation location of the host. The host can be installed in a ventilated area and can be wall mounted, flat, or fixed on a pipeline. The closer the distance B between the host and the cable winding part, the better, generally not exceeding 2 meters.
9. The length C of the straight section of the cable wrapped pipeline should meet the following requirements:When the outer diameter of the pipeline is less than 100mm, C is greater than: pipeline outer diameter × 8+1000 (mm),When the outer diameter of the pipeline is not less than 100mm, C is greater than: pipeline outer diameter × 8+1500 (mm)
10. The winding method should comply with the right-hand law of magnetic field, that is, hold the water inlet pipe with your right hand, point your right thumb in the direction of water flow, and the direction of the other fingers is the starting direction of the cable winding. The extension direction of the cable winding should be consistent with the direction of water flow. (Cannot be reversed, otherwise it will have an impact)
11. Wrapping: First, reserve a suitable length of connection with the host at the output+end. Use matching bundling tape to fix the cable on the pipeline and secure it firmly to prevent it from falling off. Look at the section in the direction of water flow and wrap it clockwise at the same time. Adjacent cables should be tightly attached and not overlap. After winding the specified number of turns, fix it with bundling tape and reserve a section of output - connection. The winding is completed.
12. Wrap and fasten the cable with tape outside to prevent it from loosening and from being damaged by rubbing.
13. For closed-loop circulating water systems, sewage valves should be installed at low points or locations where dirt is prone to accumulate, and regular sewage discharge can be carried out according to the water quality.
14. Fence around the water treatment plant to prevent damage to the equipment.
That's allPeide Broad Spectrum Induction Water ProcessorAn issue that must be taken seriously, details determine success or failure, and it is also important to ensure stable operation and long service time. Jiangsu Peide Water Treatment Equipment Co., Ltd. has been dedicated to the research and manufacturing of physical descaling equipment for hot water systems and circulating water systems since 2004,Since its operation, the water pump has not experienced scaling or jamming faults, effectively reducing maintenance time.