Welcome Customer !

Membership

Help

Shaoxing Shangyu Juli Fan Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

DBF-6.3Q8 bottom blowing low-noise transformer cooling axial fan

NegotiableUpdate on 04/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The DBF-6.3Q8 bottom blowing low-noise transformer cooling axial fan is installed in the radiator cooling system of large transformers and reactors. Relatively high air volume and low noise. $r $n $r $n is divided into bottom blowing and side blowing types. The bottom blowing type is installed with a flange on the air duct, while the side blowing type is installed with a bracket or can be installed with a flange. Specific installation methods can be customized for customers $r $n $r $n Specification: Fan diameter: amp; amp; amp; Phi; 400-1200 mm, Air volume 3100-35000 m3/h, air pressure 45-165 Pa
Product Details

DBF-6.3Q8底吹式低噪音变压器冷却轴流风机DBF-6.3Q8底吹式低噪音变压器冷却轴流风机DBF-6.3Q8底吹式低噪音变压器冷却轴流风机DBF-6.3Q8底吹式低噪音变压器冷却轴流风机DBF-6.3Q8底吹式低噪音变压器冷却轴流风机DBF-6.3Q8 bottom blowing low-noise transformer cooling axial fan

3.1 Surrounding air temperature: -40 ℃ to 75 ℃.

3.2 Relative humidity of the air: The average maximum relative humidity in a humid month is 95%, and the average minimum temperature in that month is 25 ℃.

3.3 The altitude is less than 1000m (when it exceeds 1000m, the temperature rise of the motor should be corrected according to the standard).

3.4 Maximum intensity of solar radiation: 0.98Kw/m2.

3.5 Maximum rainfall intensity: 50mm/10min

3.6 Sand dust, ice, snow, frost, dew: Yes.

3.7 The motor adopts Class B insulation. When the altitude is less than 1000m and the ambient air temperature is less than 75 ℃, the temperature limit of its stator winding (resistance method) is less than 45K, and the allowable temperature of the bearing (thermometer method) is less than 95 ℃.

3.8 Adopting low-noise bearings, under normal operating conditions, it can withstand rated load continuous operation, with a service life of 10 years, and can ensure safe operation for no less than 5 years before * major repairs.

4. Product model and technical parameters (see Appendix 1)


5.2.3 Conduct an idle operation test on the motor according to the prescribed power supply (without impeller). The motor should start flexibly, run smoothly and lightly, and produce harmonious sound. When the three-phase power supply is balanced, the deviation between any phase and the average value of the three-phase no-load current of the motor should not exceed 10% of the average value of the three-phase.

5.2.4 Connect the whole machine to the power supply for trial operation, check the rotation direction and operation condition. After the test is normal, it can be put into operation.

DBF-6.3Q8 bottom blowing low-noise transformer cooling axial fan
5.3.5 When disassembling and repairing the machine, the residue such as lubricating grease should be cleaned first, and all bearings should be thoroughly cleaned and inspected. Discovering faults should be dealt with promptly (refer to the table of common faults and handling methods). If the winding is rewound, a withstand voltage test should be conducted. The new winding should be able to withstand an AC voltage of 2000V for 1 minute without breakdown. For factory products, when the user requests a repeated withstand voltage test, the test voltage should be 1600V and the time should be 1 minute. If *, reassemble and add new lubricating grease.

5.3.6 Regularly replenish lubricating grease: Fully sealed bearings do not need to replace lubricating grease within 5 years. For non fully sealed bearings, the oil cup should be cleaned before oil injection; This product uses lithium based grease and cannot be replaced with other grease at will; Inject lubricating oil into the oil cup with an oil gun, with an amount of about 2/3 of the bearing space. It should be added every 2-3 years during normal use.

Common faults and their solutions

serial number
Fault phenomenon
Possible causes
treatment method
1
Temperature too high
1. Blockage of the intake passage or foreign objects in the air duct causing excessive load;
2. The impeller is severely deformed or damaged;
3. The power supply voltage or frequency is too low and does not comply with regulations;
4 single-phase operation;
Friction between the fixed rotor and other rotating components.
1. Remove foreign objects to ensure smooth air intake;
2. Replace the impeller;
Replace the motor with one that meets the user's voltage and frequency level;
4. Eliminate faults in fuses and motor windings;
5. Adjust the installation again.
2
excessive current
1. The bearing is severely worn;
2. Single phase operation of motor winding;
The impeller and air duct are stuck;
The voltage or frequency does not match.
1. Replace the bearing;
2. Eliminate circuit or winding open circuit faults;
Adjust the clearance between the impeller and the air duct;
4. Check if the voltage or frequency matches the motor.
3
Large noise and vibration
1. The impeller is severely damaged;
Two feet are loose.
1. Replace the impeller;
Tighten the loose parts.
4
Low insulation resistance
1. Store in water, store in damp conditions.
Dry before use.



6. Transportation and storage

During the transportation process, it is important to handle with care and follow the markings on the packaging box. Do not invert.

6.2 During transportation, severe impact vibrations should be avoided to prevent damage.

6.3 The storage location should be kept ventilated, dry, clean, and free of corrosive gases. During storage and transportation, rain protection measures should be taken.

6.4 If it is not immediately put into operation, it is not advisable to open the box immediately. If the packaging box is damaged, it should be opened for inspection and handled properly.

7. Ordering Instructions

7.1 When placing an order, please provide detailed information on the product model, technical parameters, and installation structure type.

When ordering accessories, please specify the machine model, accessory name, and specifications.

7.3 The technical parameters and installation dimensions in this manual are for user reference only. If there are any changes in the data, the agreement between the supply and demand parties shall prevail and shall not be corrected.

7.4 If there are special requirements, special specifications and models of products can be supplied after mutual agreement.