Electric cast iron copper inlaid gate

NegotiableUpdate on 04/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Electric cast iron inlaid copper gate, ZMQY electric cast iron inlaid copper round gate, ZSQF electric wall type bidirectional cast iron inlaid copper gate, electric flange cast iron inlaid copper gate, SYZ electric cast iron inlaid copper round square gate, ZMQF electric cast iron inlaid copper square gate are mainly used in water supply and drainage, flood control, irrigation, water conservancy, and hydropower projects to cut off, dredge water flow or regulate water level. The control of flow rate and liquid level is an important equipment for water supply, drainage, and sewage treatment. Mainly installed at pipeline entrances and intersecting shafts, sedimentation tanks, settling tanks, diversion channels, pump station inlets, etc.
Product Details

Electric cast iron copper inlaid gate
Product Overview
Electric cast iron copper inlaid gate, ZMQY electric cast iron inlaid copper round gate, ZSQF electric wall type bidirectional cast iron inlaid copper gate, electric flange cast iron inlaid copper gate, SYZ cast iron inlaid copper electric gate, ZMQF electric cast iron inlaid copper square gate, ZMQY-I electric circular gate, electric concealed rod cast iron inlaid copper gate,Electric circular cast iron inlaid copper gate, flashlight dual-use cast iron inlaid copper round gate, electric cast iron inlaid copper round gate, flashlight dual-use cast iron inlaid copper round gate, electric cast iron inlaid copper two-way water stop round gate, electric circular cast iron inlaid copper gate, electric cast iron inlaid copper round gate, electric cast iron round gate, ZMF circular cast iron inlaid copper electric gateIt is composed of an electric belt with a manual actuator, a hoist, and a cast iron copper inlaid circular gate. It is mainly used in water supply and drainage, flood control, irrigation, water conservancy, and hydropower projects to cut off, dredge water flow or regulate water level. The door frame and gate are both made of high-quality gray cast iron or ductile iron. The guide rails are symmetrically arranged on both sides and connected to the two ends of the door frame with stainless steel bolt positioning pins (for small and medium-sized gates, the guide rails can be cast as a whole with the door frame). The length of the guide rail is generally 1/2 to 1/3 of the full opening height of the gate, so the overall structural strength is high, rigidity is high, wear resistance, corrosion resistance is good, and pressure bearing capacity is large. The gate plate is a water blocking component that directly bears water pressure, and the gate frame is the supporting component around the gate plate. It is also the sliding track for the up and down movement of the gate plate. The outer part of the sliding track is embedded in the second phase concrete of the gate pier and gate bottom, evenly transmitting the water pressure borne by the gate plate to the gate pier and gate chamber bottom. The contact area between the upstream face of the gate frame and the downstream face of the gate frame is mechanically refined and polished to be straight, smooth, and tightly fitted, so that the joint surface, water stop surface, and motion slide are integrated into one. Under the action of the hoist, when the gate is opened and closed, the closed inclined iron and the gate frame slide ensure the longitudinal and transverse running trajectory of the gate. Under the dual action of water pressure and the closed inclined iron, the gate runs smoothly, making the gate closely fit with the gate frame slide, thus achieving the purpose of effective water stop. Widely used in water intake and transportation, municipal construction, water supply and drainage, farmland irrigation and other projects, it is usually set at the inlet of channels and culverts, used as a working gate to regulate flow, control water level, or as a maintenance gate to close the orifice and block water. There are two types of cast iron gates: square and circular. Cast iron gates are generally composed of two parts: door leaves and door frames. The material of the door body and door frame is cast iron, which is generally cast and processed as a whole. Widely used in urban water supply and drainage, metallurgy, petroleum, chemical, irrigation, power, textile and other industries for water treatment structures, to achieve flow and liquid level control is an important equipment for water supply and drainage and sewage treatment. Mainly installed at pipeline entrances and intersecting shafts, sedimentation tanks, settling tanks, diversion channels, pump station inlets, etc.

Main component materials of cast iron inlaid copper gate:

door frame

ram

guide rail

screw

sealing surface

Ht200

Ht200

Ht200

1Cr18,2Cr13,Ni9Ti13,.304,316

Zcu8-2-2

Technical Specifications:

structural form

Bright pole type, bi-directional pressure bearing type

Drive Type

Handwheel type, hand cranked, flashlight dual-purpose opening and closing machine, electric opening and closing machine

Installation type

Wall mounted, flange mounted

Applicable Medium

Sewage, seawater, and clean water

Debugging and operation of the hoist:
1. Under no-load conditions, ensure that the three-phase current imbalance does not exceed plus or minus 10%, and measure the current value.
2. Adjustment of upper and lower limits: When the gate is fully closed, press the upper limit switch tightly and fix it on the screw. When the gate is fully open, press the lower limit plate down on the travel switch and fix it on the screw.
3. The main command adjustment of the hoist must ensure that the error when the gate is raised and lowered to the upper and lower limit positions does not exceed 1cm.
4. After installation, it is necessary to conduct a trial run. First, conduct a no-load test by letting the screw travel twice and listening for any abnormal sounds to check if the installation meets the technical requirements. Conduct a load test, perform two strokes under rated load, observe the operation of the screw and gate, and check for any abnormal phenomena. Only after confirming that there are no errors can it be officially put into operation.
5. Operators must master the structure, performance, and operation methods of the hoist, and have a certain level of mechanical knowledge to ensure the normal operation of the machine.
6. Before operation, conduct a comprehensive inspection of the hoist to ensure that all parts are lubricated properly and that the bolts are not loose. Check if the power circuit is connected and if the switch is in good condition during electric opening and closing.
7. During electric operation, the operator must not leave the site and immediately stop the machine if any problems are found.
8. When repairing the hoist, the load must be removed.
9. When in use, lubricating oil should be injected through the oil injection hole at any time, and sufficient lubricating oil should be maintained regularly. The screw should be regularly cleaned of oil stains and coated with new oil to prevent rust and corrosion.

Screw type opening and closing machineInstallation, commissioning and maintenance:

1. Be sure to maintain the basic layout plane at a horizontal angle of 180 degrees; The contact area between the base of the hoist and the foundation layout plane should reach over 90%; The screw axis should be perpendicular to the horizontal plane measured on the gate platform; It should be aligned vertically with the lifting ear hole of the gate plate to avoid tilting the screw, which may cause local stress and damage to the machine parts.

2. Place the hoist in the installation position. Put a limit plate on the screw, screw the screw into the hoist from the lower part of the crossbeam, and when the screw is exposed from above the hoist, then put on the limit plate. The lower part of the screw is connected to the gate.

3. The installation of the foundation building for the hoist must be stable and safe. The concrete for the machine base and foundation components shall be poured according to the drawings. When the concrete strength does not reach the design strength, it is not allowed to remove or change the temporary support of the hoist, nor to conduct trial mixing and operation.

4. Install the hoist according to the lifting centerline of the gate, align the center so that the deviation of the longitudinal and transverse centerlines does not exceed plus or minus 3mm, and the elevation deviation does not exceed plus or minus 5mm. Then pour the second phase concrete or connect it with the embedded steel plate.

5. The installation of electrical equipment for the hoist shall comply with the provisions of the drawings and instructions, and all electrical equipment shall be reliably grounded.

6. After the installation of each hoist, clean it, repair any damaged protective paint, and apply lubricating grease.


Precautions for selection of cast iron inlaid copper gate:

1. Water head (H) refers to the height from the highest water level to the bottom of the gate;

2. The opening and closing forces in the above table are under positive pressure;

3. The tonnage in the table includes the self weight of the gate and does not include the pre opening force;

4. The size of the pre air force is related to the number of blocks, slope, and processing accuracy of the gate, generally ranging from 60% to 95% of the opening force;

5. The force for selecting a hoist is generally 1.6 to 2 times the opening force;

6. The opening and closing force of other specifications of gates shall be approximately calculated based on the bearing area in this table.

Precautions for installation of cast iron inlaid copper gate:

1. Reserve installation positions for gates and hoists according to the requirements in the pre embedded diagram;

2. Use a plumb bob to embed the embedded parts in a straight line, ensuring that their surface and verticality are within the range of 1.5~3 ‰;

3. Fix the door frame and guide rail onto the embedded parts with bolts;

4. When the slenderness ratio of the screw (lifting rod length/screw outer diameter) 4H/d>200, a shaft guide frame should be installed, and the distance between the shaft guide frame and the gate lifting ear should be greater than the maximum opening degree of the gate.


Main external connection dimensions of cast iron copper inlaid round gate: Unitmm

model

Diameter DN

A

A1

B

B1

C

D1

E

H

b

φd

4-φd1

ZMQY-300

300

407

300

150

75

200

320

44

562

20

16

4-φ22

ZMQY-400

400

524

400

206

122

256

420

51

750

25

20

4-φ25

ZMQY-500

500

644

500

236

135

312

520

60

870

25

20

4-φ25

ZMQY-600

600

764

600

255

152

368

620

60

983

25

20

4-φ26

ZMQY-700

700

884

700

280

158

430

724

74

1262

30

25

4-φ28

ZMQY-800

800

984

800

280

158

478

824

74

1392

30

25

4-φ28

ZMQY-900

900

1105

900

340

170

525

928

105

1750

30

25

4-φ32

ZMQY-1000

1000

1205

1000

370

190

590

1030

110

1828

35

30

4-φ32

ZMQY-1200

1200

1425

1200

405

220

695

1232

115

2182

35

30

4-φ32

ZMQY-1500

1500

1766

1500

425

225

840

1536

115

2933

80

30

4-φ32

Cast iron copper inlaid square gateMain external connection dimensions: Unit: mm

model

Diameter DN

A

B

E

H

b

φd

ZMQF -300

300×300

425

145

55

600

20

φ20

ZMQF -400

400×400

550

150

60

885

20

φ20

ZMQF-500

500×500

615

195

70

1000

30

φ25

ZMQF -600

600×600

720

205

83

1200

30

φ25

ZMQF -700

700×700

848

236

91

1400

30

φ25

ZMQF -800

800×800

945

265

110

1600

30

φ30

ZMQF -900

900×900

1100

290

145

1600

30

φ30

ZMQF -1000

1000×1000

1200

325

155

1700

35

φ30

ZMQF-1200

1200×1200

1400

360

170

2335

40

φ30

ZMQF -1400

1400×1400

1630

420

200

2720

40

φ35

ZMQF -1500

1500×1500

1750

450

215

2900

40

φ35

ZMQF -1600

1600×1600

1870

480

230

3100

40

φ35

ZMQF -1800

1800×1800

2025

520

250

3356

40

φ35

ZMQF-2000

2000×2000

2220

570

270

3680

50

φ40

ZMQF -2200

2200×2200

2440

626

300

4040

50

φ40

ZMQF-2500

2500×2500

2740

700

340

4580

50

φ40

Note: The above product introduction, parameters, images, and data are for reference only

ZMQY/FElectric cast iron copper inlaid round square gate, ZMY electric cast iron copper inlaid round gate, ZSQF electric wall type bidirectional cast iron copper inlaid gate, electric flange cast iron copper inlaid gate, SYZ electric cast iron copper inlaid square gate, ZMQF electric cast iron copper inlaid square gate, ZMQY-I electric circular gate, electric concealed rod cast iron copper inlaid gate,Electric circular cast iron inlaid copper gate, flashlight dual-use cast iron inlaid copper round gate, electric cast iron inlaid copper round gate, flashlight dual-use cast iron inlaid copper round gate, electric cast iron inlaid copper two-way water stop round gate, electric circular cast iron inlaid copper gate, electric cast iron inlaid copper round gate, electric cast iron round gate, ZMF circular cast iron inlaid copper electric gate】This product is produced by【Henan Nasway Valve Co., Ltd】Production. The company respects the corporate spirit of "steadfastness, hard work, and responsibility", and adheres to the business philosophy of "integrity wins the world" and creates a good office environment. With a new management model, advanced technology, thoughtful service, and integrity as the foundation of survival, we always adhere to the principle of putting users first and serving customers with heart, and strive to impress customers with our own services. Welcome new and old users to visit and guide our work. If you are interested in the product or have any questions, you can leave us a message or contact us directly. We will contact you immediately after receiving your message. Looking forward to working together with you to create brilliance! Your satisfaction is our eternal pursuit!