Welcome Customer !

Membership

Help

Shanghai Kaiyuan Automation Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Shanghai Kaiyuan Automation Technology Co., Ltd

  • E-mail

    3007052287@qq.com

  • Phone

    13482468385

  • Address

    Building 1, No. 188 Xinghuo Road, Qingcun Town, Fengxian District, Shanghai

Contact Now

Electronic equipment circuit breaker CBMC E4 24DC/1-10A NO

NegotiableUpdate on 03/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Electronic equipment circuit breaker CBMC E4 24DC/1-10A NO $r $nCBMC E4 24DC/1-10A NO - Electronic equipment circuit breaker $r $n2906032 $r $n multi-channel electronic equipment circuit breaker, can protect four loads 24 V DC in overload and short circuit situations. Equipped with an electronic lock for setting the rated current. Installed on a DIN rail.
Product Details

Electronic equipment circuit breaker CBMC E4 24DC/1-10A NO
CBMC E4 24DC/1-10A NO
-Electronic device circuit breaker
2906032

Multi channel electronic device circuit breaker, capable of protecting four loads at 24 V DC in case of overload and short circuit. Equipped with an electronic lock for setting the rated current. Installed on a DIN rail.

电子设备断路器CBMC E4 24DC/1-10A NO电子设备断路器CBMC E4 24DC/1-10A NO电子设备断路器CBMC E4 24DC/1-10A NO

Electronic equipment circuit breaker CBMC E4 24DC/1-10A NO
Product Details




Overview
Precautions Repeated hard short circuits can reduce the melting point of integrated backup fuses.

Product Type Equipment circuit breaker
Product Series CBMC
type Rail installation module, single piece
digit 1
Number of channels 4
Insulation characteristics
protection level III
pollution level 2

Overview
Working Voltage 18 V DC . .. 30 V DC
rated voltage 24 V DC
Nominal working current IN 40 A DC (IN+)
40 A DC (at each connection point position when bridging additional devices through IN+)
Nominal working current IN 1/2/3/4/5/6/7/8/9/10 A DC (adjustable for each output channel)
Rated current (pre adjusted) 4 A
Rated overvoltage 0.5 kV
Breaking method E (Electronic)
feedback resistor 35 V DC
Required spare fuse Only in the I of the power supplymax>The capacity of the short-circuit switch is required. Built in fault safety components.
Short circuit switch capacity 300 A
dielectric strength 35 V DC (load circuit)
fuse electronic
efficiency > 99 %
Closed circuit current I0 Typical value 25 mA
power consumption Typical value 0.6 W (no load operation)
<9 W (normal operation)
Module initialization time 1.6 s
Waiting time after closing a channel 5 seconds (overload/short circuit)
Measurement tolerance I ± 15 %
Temperature decay 24 A DC (at 60 ° C)
28 A DC (at 54 ° C)
32 A DC (at 47 ° C)
36 A DC (at 41 ° C)
40 A DC (at 35 ° C)
MTBF (IEC 61709, SN 29500) 8403361 h (at 25 ° C and 21% load)
3067484 hours (at 40 ° C, 34.25% load)
534188 hours (at 35 ° C,% load)
Failed safety components 15 A DC (per output channel)
load circuit
downtime ≤ 10 ms (applicable for short circuits>2.0 x I)N)
1 s (1.2 ... 2.0 x IN)
Under voltage shutdown ≤ 17.8 V DC (active)
≥ 18.8 V DC (passive)
Overvoltage shutdown ≥ 30.5 V DC (active)
≤ 29.5 V DC (passive)
Capacitive load 45000 µ F (depending on current setting and available short-circuit current)
Indicator/remote signal transmission
Connection Name Remote signaling alarm circuit
Switching function N/O contact
Nominal working voltage 0 V DC . .. 30 V DC
Operating current mA DC

Main circuit IN+
connection method Direct insertion connection
Stripping length 15 mm
Rigid wire cross-section 0.2 mm² . .. 10 mm²
Connectable guide cross-section AWG 24 . .. 8
Flexible wire cross-section, with conduit and plastic insulation conduit 0.25 mm² . .. 4 mm²
Flexible wire cross-section with cold head without insulation sleeve 0.25 mm² . .. 6 mm²
Main circuit IN-
connection method Direct insertion connection
Stripping length 10 mm
Rigid wire cross-section 0.2 mm² . .. 2.5 mm²
Connectable guide cross-section AWG 24 . .. 12
Flexible wire cross-section, with conduit and plastic insulation conduit 0.25 mm² . .. 1.5 mm²
Flexible wire cross-section with cold head without insulation sleeve 0.25 mm² . .. 2.5 mm²
Main circuit OUT
connection method Direct insertion connection
Stripping length 10 mm
Rigid wire cross-section 0.2 mm² . .. 2.5 mm²
Connectable guide cross-section AWG 24 . .. 12
Flexible wire cross-section, with conduit and plastic insulation conduit 0.25 mm² . .. 1.5 mm²
Flexible wire cross-section with cold head without insulation sleeve 0.25 mm² . .. 2.5 mm²
Remote signaling alarm circuit
Stripping length 10 mm
Rigid wire cross-section 0.2 mm² . .. 2.5 mm²
Connectable guide cross-section AWG 24 . .. 12
Flexible wire cross-section, with conduit and plastic insulation conduit 0.25 mm² . .. 1.5 mm²
Flexible wire cross-section with cold head without insulation sleeve 0.25 mm² . .. 2.5 mm²

Channel LED off Close (channel has been closed)
Channel LED yellow Flashing (channel connected, channel load>80%)
Flashing (programming mode activated)
Channel LED green Flashing (channel connected)
Channel LED red Flashing (channel closed, overvoltage or undervoltage activated)
ON temporary (channel closed, 5-second cooling phase, overload or short circuit release)
Flashing (channel closed, ready to reconnect, overload or short circuit released)
Flashing twice (channel closed, exceeding the maximum device current limit of 40 mA)

Size chart
width 36 mm
height 90 mm
depth 98 mm (7.5 mm (including DIN rail))

color Light Grey (RAL 7035)
Identification material PC
PA 6.6
PA 6.3T
POM
Flame retardant rating, compliant with UL 94 V-0

environmental conditions
protection level IP20
Environmental temperature (operating) -25 °C . .. 60 °C
Environmental temperature (storage/transportation) -40 °C . .. 70 °C
altitude ≤ 3000 m to 52 ° C (amsl)
≤ 4000 m to 46 ° C (amsl)
Humidity measurement 96 h,95 % RH,40 °C
Impact force (operation) 30g (IEC 60068-2-27, Test Ea)
Vibration (operation) 10 Hz . 57.6 Hz (amplitude ± 0.35 mm; compliant with IEC 60068-2-6, test Fc)
57.6 Hz... 150 Hz (acceleration 5g; compliant with IEC 60068-2-6, test Fc)

UL Certification
logo UL/C-UL Listed UL 508
UL Recognized UL 2367
Corrosive gas testing
logo ISA S71.04.2013 G3 Harsh Group A

standard EN 60-6-2
Precautions Electromagnetic compatibility - anti-interference capability in industrial areas
standard EN 60-6-3
Precautions Electromagnetic compatibility - emissions from residential, commercial, and commercial properties, as well as small businesses
standard EN 60068-2-6
Precautions Environmental Impact - Vibration (Sinusoidal)
standard EN 60068-2-27
Precautions Environmental Impact - Impact
standard EN 60068-2-78
Precautions Environmental impact - humidity and heat, constant
standard EN 50178
Precautions The power supply unit is equipped with electronic devices

Installation Type DIN rail: 35 mm

Order Number 2906032
packaging unit 1 pc
Minimum order quantity 1 pc
Sales key code CLA152
Product key code CLA152
Catalog page Page 375 (C-4-2019)
GTIN 4055626149356
Individual weight (including packaging) 140.2 g
Individual weight (excluding packaging) 133.94 g
Tariff number 8536200000
place of origin DE





Compatible products



advantage

Adopting a compact design and providing personalized adjustment options, devices can be easily replaced without the need for re planning
With the help of an LED button, the circuit can be adjusted without the need for any other tools
Electronic locks can reliably prevent tampering with current values
The status LED of the traffic light color can immediately recognize the current operating status