GNST-NH3 224 ammonia nitrogen online sensor has temperature pH、 Interference ion compensation function, using RS485 interface and standard Modbus protocol, with advantages such as in-situ measurement, no need for reagents, no need for preprocessing, and low maintenance.
GNST-NH3 224 Ammonia Nitrogen Online SensorIt is a probe type intelligent sensor. This product has temperature pH、 Interference ion compensation function, using RS485 interface and standard Modbus protocol, with advantages such as in-situ measurement, no need for reagents, no need for preprocessing, and low maintenance.
Application field
The instrument is widely used in industries such as environmental surface water, municipal sewage, aquaculture water bodies, and industrial process water
Product Principle
The determination principle of ammonia nitrogen is based on the relationship between the activity and concentration of ions in electrolyte solutions. It usually consists of two sensors: the working sensor and the reference sensor. A working sensor is a sensor that selectively reacts with the ion being measured, while a reference sensor provides a stable potential as a reference. Work sensors are typically coated with a selective membrane that can react specifically with specific ions. When the tested ion reacts with the selective membrane, a potential change occurs, and the concentration of the ion can be determined by measuring this potential change.
GNST-NH3 224 Ammonia Nitrogen Online SensorProduct Features
(1) Each sensor can be independently replaced, with simple operation and minimal maintenance
(2) Fast response time, real-time detection of ions in water bodies
(3) Corrosion resistant casing, waterproof rating IP68, capable of long-term underwater operation
(4) RS485 communication interface, standard Modbus protocol, easy to integrate

Technical parameters
working principle |
Ion selection method |
Measurement factor |
NH4N |
Product Model |
GNST-NH3 224 |
Measurement factor |
ammonia nitrogen |
pH |
temperature |
measurement range |
0.1~1000mg/L |
pH 0~14 |
0~50 ℃ |
repetitiveness |
≤ 2% |
≤0.3℃ |
≤0.3℃ |
measurement accuracy |
± 5% or ± 0.1mg/L |
<0.1ph |
<0.3℃ |
Compensation scope |
pH 4~10 |
Low concentration float (24h) |
±1%F.S |
Range drift (24 hours) |
±3%F.S |
detection limit |
0.05mg/L |
resolution |
0.01mg/L |
Protection level |
IP68 |
communication interface |
RS485, Standard Modbus protocol baud rate 9600 Address bits Factory default 50 |
Dimensions |
(50 * 251) mm cable 10 meters (customizable) |
material |
316L stainless steel/PVC/titanium alloy optional |
weight |
2KG |
install thread |
Upper NPT3/4 thread |
Working Voltage |
9~36V DC |
MTBF |
≥ 1440h/time |
power consumption |
0.5w |
School governance cycle |
1-3 months (depending on the on-site water quality environment) |
working environment |
(0~50)℃ |