GNST-SD237 online chromaticity sensor is a dual beam probe type intelligent sensor that effectively reduces turbidity interference through automatic compensation. It comes with a cleaning brush to avoid the influence of attachments and bubbles on measurement. The analyzer adopts RS485 interface and standard Modbus protocol to quickly respond to changes in water color.
GNST-SD237 online chromaticity sensor
The chromaticity online sensor is a dual beam probe type intelligent sensor that effectively reduces turbidity interference through automatic compensation. It comes with a cleaning brush to avoid the influence of attachments and bubbles on the measurement. The analyzer adopts RS485 interface and standard Modbus protocol to quickly respond to changes in water color.
Application field
The instrument is widely used in industries such as environmental surface water, sewage treatment, drinking water, swimming pools, etc. and has received high praise from a large number of users.
GNST-SD237 online chromaticity sensorProduct Principle
Using two light sources, one is used to measure chromaticity, and a system composed of light sources, photoelectric diodes, quartz windows, etc. is used to simulate human observation. An algorithm is used to establish a stable and reliable water quality chromaticity calculation model. The other is used to measure water turbidity, and a specific algorithm is used to compensate for the attenuation of the light path and eliminate the interference of particulate suspended matter to a certain extent, thereby achieving stable and reliable measurement.

Product Features
(1) Optical detection, no need for reagents, more economical and environmentally friendly
(2) Equipped with cleaning brush and circulation pool, effectively removing attachments and bubbles from the measurement window, maintenance free
(3) Dual light path detection, automatically deducing interference from turbidity on chromaticity measurement, unaffected by turbidity
(4) Corrosion resistant casing, waterproof rating IP68, RS485 communication interface, standard ModBus protocol for easy integration
Technical parameters
model |
GNST-SD237 |
working principle |
Spectral absorption method |
measurement range |
0-500 Hazen |
linearity |
R²>0.999 |
Zero drift (24h) |
±1%F.S. |
Range drift (24 hours) |
±3%F.S. |
response time |
≤30s |
Protection level |
IP68 |
communication interface |
RS485, Standard Modbus protocol |
Dimensions |
(Φ46*189.5)mm, Cable 10 meters (customizable) |
material |
titanium alloy |
withstand pressure |
0. 3 Mpa |
Installation method |
Supporting circulation pool/investment installation |
Working Voltage |
(9~24)V DC |
MTBF |
≥ 1440h/time |
Cleaning Method |
Mechanical brush |
Calibration cycle |
1-3 months |
working environment |
(0~50) ℃ (non freezing) |