HANNA HANNA HI98168 portable high-precision BOD dissolved oxygen analyzer from Italy Product Introduction:
DO, BOD, OUR, and SOUR, air pressure measurement
Dissolved oxygen ultra large measurement range: 50ppm, 600% saturated dissolved oxygen
Salinity, pressure, and temperature compensation
USB data interface for data transfer
Inductive charging mode, safe and convenient
HANNA HANNA HI98168 portable high-precision BOD dissolved oxygen analyzer from Italy Product parameters:
HI98186 portable high-precision BOD dissolved oxygen analyzer | |||
project |
dissolved oxygen |
temperature |
atmospheric pressure |
measuring range |
0.00 to 50.00 mg/L; 0.0 to 600.0% |
-20.0-120.0℃; -4.0-248.0°F |
450-850 mmHg |
resolution |
0.01 mg/L; 0.1% |
0.1℃/0.1°F |
1mm Hg |
accuracy |
± 1.5% ± 1 digit of the reading |
±0.2℃/±0.4°F |
±3mmHg |
Calibration Mode |
Automatic or manual 1-point or 2-point calibration |
1 or 2 o'clock |
single-point calibration |
temperature compensation |
Automatic temperature compensation 0.0 to 50.0 ℃ 0 32.0 to 122 ° F |
||
Salinity compensation |
Automatic salinity compensation 0 to 70ppt (g/L) |
||
Atmospheric pressure compensation |
Automatic atmospheric pressure compensation 450mmHg to 850mmHg |
||
Measurement mode |
Dissolved oxygen DO, biochemical oxygen demand BOD, oxygen consumption rate OUR, specific oxygen consumption rate SOUR, atmospheric pressure, temperature |
||
Standard distribution is very |
HI76407/4F high-performance built-in temperature sensor, dissolved oxygen electric sensor, with a wire length of 4 meters |
||
data management |
400 sets of main sentences storage, USB data interface (via HI92000 data management software) |
||
Power source |
4 x 1.2V rechargeable batteries, equipped with HI710042 induction charger |
||
Adapt to the environment |
0 to 50 ℃(32 to 122°F )RH max100 |
||
Dimension |
226.5×95×52 mm/525g |
||
Standard configuration | |||
HI98186 |
Host, HI76407/4F with built-in electrical protective cover and temperature sensor with high spectrum, dissolved oxygen sensor with high voltage (wire length: 4 meters), HI76407A/P customized special dissolved oxygen film (2 pieces), HI7041S dissolved oxygen filling solution (30mL), HI710042 customized special induction charger (HI710008) |
||
AC220V/12VDC power adapter, Chinese and English user manual, HE721005 special instrument carrying case |
HI98186-0 |
||
Host, customized dedicated induction charger for HI710042 (HI710008) | |||
AC220V/12VDC power adapter, Chinese and English user manual, HE721005 special instrument carrying case |
optional accessories |
||
HI76407F |
Built in temperature sensor for dissolved oxygen, containing 2 HI70407A dissolved oxygen membranes, HI7041S dissolved oxygen filling solution (30mL), wire length: 2, 4, 10, 20, 30, 50 meters |
||
HI76407V/P |
Dissolved oxygen special film: 5 pieces; HI7041S filling solution, 30ml |
||
HI76407A/p |
Dissolved oxygen special film: 5 pieces |
||
HI7040 |
Dissolved oxygen standard solution standard value: 0 ppm specification 500ml |
||
HI7041S |
Dissolved oxygen filling also specifications 30ml |
||
HI98186-300 |
BOD glass culture bottle specification 300ml quantity 6 pieces/group |
||
HI710042 |
Inductive charger |
||
HI92000 |